background image

 

For use in GB & IE 

228091-10 

GAS TARGET TOP 

 

G57 

I N S T A L L A T I O N   A N D   O P E R A T I O N   M A N U A L  

Summary of Contents for G57

Page 1: ...For use in GB IE 228091 10 GAS TARGET TOP G57 I N S T A L L A T I O N A N D O P E R A T I O N M A N U A L ...

Page 2: ...00 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales tel 44 121 3...

Page 3: ...quirements Unpacking Location Clearances Assembly Fitting Leg Stand to Target Top Gas Connection Commissioning Operation 14 Operation Guide Description of Controls Lighting Pilot Burner Lighting Main Burner Cleaning and Maintenance 16 General After Each Use Daily Cleaning Weekly Cleaning Periodic Maintenance Fault Finding 18 Gas Conversion and Specifications 19 Conversion Procedure Gas Specificati...

Page 4: ... LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION Warning This appliance is for prof...

Page 5: ...ts Non CE Only Australia New Zealand CE Only Appliance Classification Category II2H3P Flue Type A1 Measure Burner operating pressure at target top hob manifold test point with target top burner Inner and outer ring operating at full setting Operating pressure is ex factory set through appliance regulator and is not to be adjusted apart from when carrying out gas conversion if required Refer to det...

Page 6: ...nal underside connection is available All Other Models Gas supply connection point is located 130mm from right hand side of appliance 32mm from rear 655mm from floor and is entered from beneath appliance An optional underside connection is available Connection is BSP male For Refrigeration Cabinet Specifications refer to Refrigeration Cabinet Installation and Operation Manual supplied with applian...

Page 7: ...Dimensions 5 G57 B Weight Nett G57 B 160 kg Rating Plate Location Gas Connection Point ...

Page 8: ...Dimensions 6 G57 LS Weight Nett G57 LS 180 kg Rating Plate Location Gas Connection Point ...

Page 9: ...Dimensions 7 G57 CB Weight Nett G57 CB 200 kg Rating Plate Location Gas Connection Point ...

Page 10: ...Dimensions 8 G57 RB Weight Nett G57 RB 240 kg Including the Refrigeration Cabinet Rating Plate Location View through slots in door Electrical Connection Point Gas Connection Point ...

Page 11: ...o be adjusted by an authorised service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from appliance including all protective plastic coating from exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to carrier and distributor Ensure all 4 adjustable feet are fitted with the protruding...

Page 12: ...Refer to Leg Stand Models Only information below for assembly instructions All Models are delivered completely assembled No further assembly is required with exception of Leg Stand Model G57 LS this will require assembly Refer to Fitting of Adjustable Feet Rear Rollers to Leg Stand Units information overleaf for assembly instructions Appliance rear leg housings can be fitted with Adjustable feet t...

Page 13: ...crewing two front adjustable feet supplied into base of front hob legs Secure each adjustable foot hand tight 8 Fit rear rollers to rear leg ring plates and secure using the locating bolts supplied Tighten bolts using a 10mm spanner 9 Lift target top back onto its legs 10 Refit all fire bricks 2 half plate castings and centre casting to target top NOTE This appliance is fitted with adjustable feet...

Page 14: ...ant that adequately sized piping runs directly to connection joint on appliance with as few tees and elbows as possible to give maximum supply volume 3 Fit gas regulator supplied into gas supply line as close to appliance as possible NOTE Gas pressure regulator provided with this appliance is convertible between Natural Gas and LPG as per Gas Conversion Section in this manual Ensure regulator is c...

Page 15: ...cified in Operation section of this manual Light the Pilot Burner Light the Main Burner Check the Low Fire burner operation Check the High Fire burner operation Ensure operator has been instructed in areas of correct lighting operation and shutdown procedure for appliance This manual must be kept by owner for future reference and a record of Date of Purchase Date of Installation and Serial Number ...

Page 16: ...n Burner Temperature Zones Description of Controls Pilot Burner Viewing Hole Gas Control Knobs OFF Position PILOT Burner HIGH Flame LOW Flame Fig 3 For Refrigeration Cabinet Operation details refer to Refrigeration Cabinet Installation and Operation Manual supplied with appliance This appliance is for professional use and is only to be used by qualified persons Only authorised service persons are ...

Page 17: ...ill be burning at full rate For a lower heat turn knob fully anti clockwise to LOW position 5 For intermediate heat position control knob between HIGH and LOW positions NOTE Always set control knob to HIGH position when lighting main burner If pilot burner goes out during normal operation wait 5 minutes before relighting 6 Cast iron work surface has a heat pattern that can be used effectively by p...

Page 18: ...t solution and a soft scrubbing brush 2 Brush Target Top cast iron with a soft bristled brush followed by wiping with a cloth to prevent accumulation of carbon 3 Remove drip tray and clean with a mild anti bacterial detergent and hot water solution using a soft bristled brush Dry drip tray thoroughly with a dry cloth 4 Dry target top thoroughly with a dry cloth and polish with a soft dry cloth Wee...

Page 19: ...nly be carried out by a qualified service person To achieve the best results cleaning must be regular and thorough and all controls and mechanical parts should be checked and adjusted periodically by a qualified service person If any small faults occur have them attended to promptly Don t wait until they cause a complete breakdown It is recommended that the appliance is serviced every 6 months Gas...

Page 20: ...uthorised service agent They are not to be adjusted by an unauthorised service person This section provides an easy reference guide to more common problems that may occur during operation of your equipment The fault finding guide in this section is intended to help you correct or at least accurately diagnose problems with your equipment Although this section covers the most common problems reporte...

Page 21: ...ectors and replace with correct size injectors as shown in Gas Specifications Tables at rear of this section 3 Refit main burner to target top NOTE Ensure main burner is pulled fully towards front of unit before tightening 2 main burner securing screws 4 Set burner aeration screws X and Y for correct gas type aeration as shown in Gas Specifications Tables at rear of this section Pilot Burner 1 Dis...

Page 22: ...letion of low fire adjustment Gas Regulator NAT Gas LPG Butane Only NOTE Gas regulator supplied is convertible between Natural Gas and LP Gas but it s outlet pressure is fixed ex factory and is NOT to be adjusted Gas Type Identification Label On completion of gas conversion replace gas type identification label located at Rear of the unit above gas connection Beside the Rating Plate Commissioning ...

Page 23: ...atural Gas LP Gas Propane Main Burner Injector Inner Ring Ø 1 70mm Ø 1 10mm Main Burner Injector Outer Ring Ø 2 60mm Ø 1 55mm Pilot Burner Injector 0 35 0 25 Burner Aeration Screw X Inner 25mm 25mm Burner Aeration Screw Y Outer 28mm 28mm Low Fire Adjustment 21 2 turns out ccw 1 turn out ccw Operating Pressure 1 0 kPa 2 6 kPa Gas Regulator Cap Screw Natural Gas G20 Propane G31 Main Burner Injector ...

Page 24: ...ropane Convertible 3 4 BSP F F General 227012 Centre Casting 227013 Half Plate Casting 014997 Casting Removal Tool 227850 Adjustable Leg 150 mm 229674 Rear Roller Assy Not Bench Models 232351 Rear Roller Assy 3 Refrigeration Base Accessories 228801 Refrigerator Base Plinth Kit 228799 Cabinet Base Leg Stand 900 mm Plinth Kit Gas Conversion Kits IMPORTANT Only genuine authorized replacement parts sh...

Page 25: ......