Product Training- 

Imperia 

  

    

By

R & I-WPD

Summary of Contents for IM3BSAM01

Page 1: ...Product Training Imperia By R I WPD ...

Page 2: ...Imperia Imperia model comes with 3 different Variants 2 SKU s 1 Imperia RO UV UF with Mineralizer 2 Imperia RO UV 3 Imperia RO Black Silver White Silver ...

Page 3: ...ors 1 Power On Glows blue when the unit is ON 2 Purification On Glows blue when the purification process is ON 3 Tank Full Glows blue when the storage tank is full 4 Filter Change Alert The LED glows red when the filter requires replacement 5 UV Fail Alert The LED Glows red when the UV lamp stops functioning and requires replacement 1 2 3 4 5 Product Specification Features ...

Page 4: ...wer consumption 36 W 36 W 30 W Product dimensions mm 361 W X 234 D X 475 H Specification Sl No Input Feed water characteristics 1 Applicable input water TDS in PPM up to 2000 ppm 2 Applicable input water hardness mg L 300 ppm 3 Applicable input water temperature 4 38 4 Applicable water pressure PSI 4 40 5 Applicable pH 5 8 8 5 6 Applicable voltage supply AC 230V 50Hz ...

Page 5: ...Treatment Train Flow Diagram ...

Page 6: ...alls Life Approx 3000 Liters 4 RO Membrane Suitable Pressure Psi Brand Dow BW60 Capacity 75 GPD Life Approx 8000 Liters 1 year 5 UF Membrane Suitable Pressure up to 4Psi Size 4 L Diameter of Filter Pore 0 01 Micron Media Material Life Approx 5000 Liters 6 UV UV Lamp Wattage 4 W Brand Philips Size 6 L Life Approx 6000 Hrs of burning 7 Post carbon Filter with ATB Suitable Pressure 40 60 Psi Size 10 ...

Page 7: ...Electrical Wiring Diagram ...

Page 8: ...ing the system PART I ASSEMBLE THE FILTERS AND HOUSINGS ONTO THE MAIN SYSTEM 1 Remove plastic wrappings on the Filter Membrane filters put the Membrane into the housings and assemble the housings onto the main system as follow 2 See Fig Stand the housings upright Make sure each housing has a rubber O ring in its groove Put Membrane Filter into the housing 3 Hand twist the housing onto the main sys...

Page 9: ... and water flow direction as mentioned on the filter cartridge Pre Carbon filter Flush the Pre Carbon filter for 3 5 minutes Now reverse tubing from input to output and flush for 3 5 minutes Now again connect to input of the cartridge and flush for 3 5 minutes Sediment Filter Remove the existing tubings Connect the output of Pre Carbon filter to the input of the SF and flush for the 10 minutes Con...

Page 10: ...tput of Pre CF and flush for 10 minutes Now again connect again to input to the filter and flush for 5 minutes Sediment Filter Remove the existing tubings Connect the output of Pre Carbon filter to the input of the SF and flush for the 5 minutes Now reverse the connection from input to the output of SF and flush for 10 minutes Again connect to the input and flush for the 5 minutes Connect the tubi...

Page 11: ...pply to the purifier Drain the tank Remove the back cover 2 Remove the faucet Unscrew Four screw at the back size of the main body to it take out from the main cover 3 Unscrew two screws at the back side of main body to remove the tank cover 4 Clean the tank with purified water ...

Page 12: ...ntioned in the installation procedure Then put back all tubings QC fittings and turn ON the water supply and power supply and check for any leakage Put back the back cover RO Membrane Remove the tubings and FRT Open the housing cap by turn in anticlockwise by hand wrench key Remove the RO membrane from the housing Take a new RO membrane and put it into the housing and put back the cap by screwing ...

Page 13: ...4 Remove the tubings and electrical connections to the Booster Pump Unscrew four screw that mounting the booster pump to tray and remove it 5 Take a new Booster Pump put on the mounting plate and screw it Put tubing connection electrical connection 6 Insert the tray in the device and screw two screw at the bottom 7 Put back the RO membrane to the C clamp 8 Turn ON the water power supply and check ...

Page 14: ...ay 4 Remove the tubings and electrical connections to SV Unscrew two screw from the bottom that mounting SV to the tray 5 Take a new SV put on the mounting plate and screw it Put tubing connection electrical connection 6 Insert the tray in the device and screw two screw at the bottom 7 Put back the RO membrane to the C clamp 8 Turn ON the water power supply and check for the operation leakage 9 Pu...

Page 15: ... the component mounting tray 4 Remove the electrical connections from the Filter Change Indicator UV Choke 5 Take a new Filter Change Indicator UV Choke put on the mounting plate and tie it Put all electrical connection 6 Insert the tray in the device and screw two screw at the bottom 7 Put back the RO membrane to the C clamp 8 Turn ON the water power supply and check for the operation 9 Put back ...

Page 16: ...n the tank 2 Remove the back cover Identify the LPS and remove the tubings electrical connections 5 Take a new LPS Put tubing connection electrical connection 8 Turn ON the water power supply and check for the operation leakage 9 Put back the back cover 4 LPS ...

Page 17: ...ons 4 Unscrew two screws at the back side of main body to remove the tank cover 5 Remove the tank cover Take out the electrical switch from the float Unscrew the nut to remove the float sensor 6 Take a new Float sensor put it on the tank cover Put all electrical connection 7 Screw the tank cover Insert the main body in the front cover and put back faucet 8 Screw the main body to the front cover 9 ...

Page 18: ...n connectors or tubings inside the purifier are damaged defective Identify the defective connector and replace it with a new one 3 The input output connectors of the Filters RO Membrane housing UV lamp Booster Pump housing are damaged defective Identify which component has the defective connector and replace it with a new one 4 The Solenoid valve manifold is damaged defective Replace the entire so...

Page 19: ... external booster pump must be connected before the purifier inlet to increase the water pressure Have to recommend to consumer to buy a pre booster pump 2 Switch Mode Power Supply SMPS is damaged defective Check for loose a electrical connection at the Molex Terminals of the SMPS Booster pump Tighten the connections if necessary Check the 24V Dc supply at the output of the SMPS If found defective...

Page 20: ...rtridges or RO membrane Check the flow rate at every stage of filter cartridge and replace the appropriate cartridge or RO membrane 3 Booster Pump is not pressurizing water effectively because of defect or deficit power supply 1 Check water flow and pressure at pump output 2 If not sufficient check the power supply 24V DC to the pump Check power supply and output power of SMPS 3 If power supply is...

Page 21: ... connection is not correctly connected 5 LED Indicator is defective damaged 1 Check the input power supply is ON 2 Ensure that multiplex connector is connected to LED connector 3 Check the 24V DC supply is coming from the SMPS 4 Check the electrical wiring connection is proper or not 5 Change the touch sensor LED display 3 Output Water TDS is very high 1 R O Membrane is not in housing 2 Pipe conne...

Page 22: ...electrical wire connection 2 LPS is defective 1 Correct the electrical wiring connections 2 Change the LPS 6 Alert sound is coming from the device 1 Filter Change alert 2 Electrical connection is Loose or disconnected from UV lamp 3 UV fail alert 4 Defective Filter Change indicator giving false alert 5 Check electrical wiring connection 1 Check the Filter Change Indicator if the indicator reading ...

Page 23: ...und defective replace it 2 Change FRT with standard rating 8 UV is not working 1 Faulty electrical wiring diagram or loose electrical connections to UV system 2 UV choke is not getting 24V DC power supply 3 Defective UV Choke 4 UV lamp failed 1 Correct the wiring connection tighten the electrical connectors 2 Check the power supply at UV choke 3 Replace the UV choke 4 Replace UV barrel ...

Page 24: ...Thanks ...