meM-LOG-SE

  

Data logger

 

 

 

Features  

Features 

 saving 

in 

continuous mode

 or 

alarm mode

 

  scan frequency up to 100Hz per channel 

  16 analog inputs, 12 Bit, 

±

5V 

  2 digital inputs (TTL) 

 

sleep mode

 (energy-saving mode) 

 512kB 

memory, 

loop mode

 (optional) 

  1 digital alarm output 

 

(as high/low  relay output) 

  saving with real time information 

 

  external power 5V/100mA  

Applications 

  direct operation via pushbutton 

 long-term 

measurements 

  USB- or serial (RS232) connection 

 field 

applications 

  accumulator or mains operation 

  supervision of breakdowns 

 alarm 

function 

 mobile 

use 

  remote control and data inquiry via modem 

 

 

 

 

 

 

 Page 

With the 

meM-LOG-SE

, BMC 

Messsysteme GmbH introduces a 
data logger, that offers entirely 
new possibilities for many measur-
ing applications.  
 
It is a completely self-sufficient 
device, which is especially suitable 
for long-term measurements. 
 
 
Unlike a classic data logger re-
cording for a long time but with 
very low frequencies, the 

meM-

LOG-SE

 reaches 

 

... sampling rates of  

up to 100Hz ... . 

 
 
Equipped with an integrated ac-
cumulator, the 

meM-LOG-SE

 can 

be placed even in hardly accessible 
locations where neither any power 
supply nor PC connection is possi-
ble.  

So it is no problem, to realize 
measuring applications which 
require 
 

... mobility and flexibility ... 

 
in a high degree. In order to extend 
the operating time of the accumu-
lator, the device changes into an 
energy-saving mode after 1 minute 
(

Sleep Mode

) and just "wakes up" 

occasionally, e.g. shortly before 
scanning the next measuring value. 
 
 
Via  
 

... 16 analog input channels in 

the measuring range of 

±

5V ... 

 
with a resolution of 12 Bit or via  
 

... 2 digital input  

channels (TTL) ..., 

 
the measured signals are written to 
the 512kB-size memory. The chan-

nels to be saved can be defined 
explicitly.  
 
 
The scan usually proceeds until the 
memory is full. If 

Loop Mode

 is 

selected, however, the 

meM-

LOG-SE

 uses a loop memory 

where previous measuring values 
are overwritten as soon as the 
storage capacity is reached.  
 
 
In addition,  
 

... alarm values can be set ...  

 
for each channel separately. If 
measuring values are beyond this 
range, either all channels or only 
channels whose alarm values have 
exceeded the normal range are 
recorded with real time informa-
tion. When leaving the alarm area, 
storage is automatically interrupted 
(

Alarm Mode

). This is a great 

advantage for the  
 

..documentation of breakdowns.. 

 
Besides that, a  
 

... digital alarm output ... 

 
is provided as a high and a low 
active digital output channel and as 
a relay output so that in case of 
emergency e.g. machines are auto-
matically stopped or sirens are 
turned on. 

Summary of Contents for MEM-LOG-SE

Page 1: ... it is no problem to realize measuring applications which require mobility and flexibility in a high degree In order to extend the operating time of the accumu lator the device changes into an energy saving mode after 1 minute Sleep Mode and just wakes up occasionally e g shortly before scanning the next measuring value Via 16 analog input channels in the measuring range of 5V with a resolution of...

Page 2: ...ition and processing measuring files created with ST meM LOG SE can be dis played in NextView 4 as graphic signal curves and then be ana lyzed NextView 4 is also available as a stripped down Analysis version A free demo of the software is included with delivery The instruction set for program ming the meM LOG SE is com patible to the ADAM4000 series For further information please visit our homepag...

Page 3: ... each channel separately storage of either all channels to be saved or only of channels which are in state of alarm If measuring values are within their normal range again the scan is temporarily interrupted If not in Loop Mode see below the scan continues until memory is full or measurement is stopped even if a scan has been stopped with the device button it can be taken up again the new measurin...

Page 4: ...listed in the following table Pin Sub D15 meM LOG SE 1 Alarm Out H active high 9 Alarm Out L active low 8 15 Relay contact alarm 3 Digital In 1 active low 11 Digital In 2 active low 12 Scan start active low 5 13 Ground 2 4 6 7 10 14 n c In case of alarm the alarm outputs and the relay contact at pin 1 9 or 8 15 become active at the same time as long as the signal values exceed the defined range Al...

Page 5: ...ion over great distances connection of a modem 3 3 1 Serial connection RS232 The serial connection requires a 9 pole cross wired null modem cable not electrically isolated which is connected to the two 9 pole Sub D plugs of the logger and the PC to be ordered under ZUKA SER9 The serial connection of the logger is located at the back of the device If your PC only provides a 25 pole serial connectio...

Page 6: ...scan Æ turn off device measuring values are saved up until the point of turning off at least 5sec Scan running repeated and short flashing of LED fast flickering after 0 5sec after 5sec LED off Instant On temporarily inter rupt energy saving mode 0 5sec Sleep Mode not changing If you start a scan with the device button or a digital signal at the digital connector the memory must be empty This does...

Page 7: ... was put on user friendliness and reliability Administration of USB and the serial interface in one program The connection between PC and data logger is realized via the serial RS232 as well as the USB interface so that the advantages of both interfaces are available to the user see chapter 3 3 ST meM LOG SE manages both inter faces so that one device or several can be connected to USB and another...

Page 8: ... possible in all operating modes Store measuring data with different file format When reading out measuring data from the memory of the data logger ST meM LOG SE writes files in txt or lfx file format which can be displayed as table values and analyzed in various programs for word processing Notepad Wordpad Word etc and spreadsheet e g Excel Especially to mention is the storage as an lfx file the ...

Page 9: ... the software automatically SP2 do not connect with Windows Update Windows 2000 Search for a suitable driver for my device Under Windows Vista no selections have to be made The driver is found and installed automatically upon connection of the hardware because the driver package has been installed on hard disc before For the same reason no additional location needs to be entered for the driver sea...

Page 10: ...0Hz channel Sampling period 18h 12min 15sec 1sec in steps of sec 10min 55sec 350msec 0 01sec in steps of 1 100 sec Total sampling rate 16Hz 1 6kHz The total sampling rate is the sum of the sampling rates of the individual used channels e g 5 channels à 100Hz 500Hz total sam pling rate The values for accuracy always relate to the respective measuring range Errors might add at worst Digital inputs a...

Reviews: