background image

INSTRUCTIONS FOR FOOL THE GUESSER 
 

SCALE ASSEMBLY AND SETUP 
 
The scale comes crated as three major components that will need to be assembled before the Scale 
can be operated. After assembly will be the calibration of the Scale Weight Head by Weights & 
Measures, or if not required, by the operator. And last, is the Game Options Programming that will set 
the range of WIN/LOSS for the various games. 
 
 
Step 1: ***Please note. On earlier Scale models there will be a cross support with a 
pole that will need to be installed before final assembly. To install this support, turn 
the platform over. Remove the two load cells that are located closest to the three 
large holes on the platform. These will be held into place by a total of four 1/2’ nuts. 
Using a 

¾

” wrench remove the four nuts and lift the load cells off of the studs. 

Remove the four tube spacers located underneath the load cells. Install the cross 
support with the pole going through the center of the three large holes. Be sure that 
the four mounting holes line up with the studs and slide over them. Once the cross 
support is in position re- install the four tube spacers, place the load cells back onto 
the studs and re-install the four 

½

” nuts. Then run the 6 pin connector through the 

center of the pole support. 
 
 
The three major components are the Scale Face, Pedestal & Weighing Platform. 
 
Step 2: Assemble the Pedestal to the Weight Platform. The bottom of the Pedestal is identified by 
the power cord exit. This should be assembled on to the Weight Platform with the gasket and bolts 
supplied. The power cord exits the rear of the platform. There is one cable that needs to be run up the 
center of the Pedestal and will connect to the Weight Head. 
 
 
Step 3: Assemble the Scale Face onto the top of the Pedestal. There will be 2 connectors plus the 
power cable poking out the top of the pedestal. Gently tuck these back down into the pole so they will 
not be in the way of the Scale Face being placed on top. This should be done with 3 people, two must 
hold the Scale Face while another guides the position and bolts the Scale face to the Pedestal. 
 
 
Step 4: All connectors need to be plugged together to connect the Scale face to the Pedestal and 
Weighing Platform electronics. There will be a 9 pin Molex (Strobes), a 6 pin Molex (Load cells for 
Weight Head), and finally the Power Cable. The Power Cable must be plugged into the Circuit 
Breaker with both White wires on one side and both Black wires on the other side. There will be one 
black & one white wire already present on the breaker. Be sure that the Black wire you plug in is on 
the same side of the breaker as the existing Black wire. Then the White wire you plug in must be on 
the same side as the White wire already plugged in to the breaker. These wires must not be crossed. 
The GROUND (green) wires are connected with the blue Bullet Connector. BE SURE THE GROUND 
WIRE IS CONNECTED before turning on the game. 
 
Once this accomplished, the Scale can be powered up and checked for proper operation. It is 
important that the scale be placed on a flat, level, and uniform surface to obtain accurate readings. 
 

To Purchase This Item, Visit BMI Gaming | www.bmigaming.com | (800) 746-2255 | +1.561.391.7200

Summary of Contents for FOOL THE GUESSER

Page 1: ...ight Platform with the gasket and bolts supplied The power cord exits the rear of the platform There is one cable that needs to be run up the center of the Pedestal and will connect to the Weight Head Step 3 Assemble the Scale Face onto the top of the Pedestal There will be 2 connectors plus the power cable poking out the top of the pedestal Gently tuck these back down into the pole so they will n...

Page 2: ...nds to press the GAME RESET key to enter the programming mode Doing so will cause Sel Funct 1 to 9 Game Reset to Exit to be displayed on the Scale face Using the number keys select the function to be viewed or programmed Doing this will cause the display as follows Use the keys to adjust or review the function data The functions are defined as follows 1 Internal or soft meter values are displayed ...

Page 3: ...test 7 Scale Base Sections This sets the height of the scale base Use the keys to increase or decrease this value THIS IS NOMALLY SET TO 2 FOR THE STANDARD SCALE 8 Sound Test This test the various sound sources used in the game Use the keys to cycle through the sources 9 Message to Edit NOT IMPLEMENTED YET To Exit the program mode and enter the game operation mode use the Game Reset key at the Sel...

Page 4: ...Reser key is used to reset the game The Month Game To play the Month game you must put the player on the scale with his hers back to the display Then you will enter the birth month guess using the numeric keys followed by Enter The numbers used to enter the months are 1 January 2 February 3 March and so on to enter October November December simply enter 10 11 or 12 followed by the Enter key At thi...

Reviews: