Page 4: ...VTM3000 Digital room thermostat User and service manual version 1 2 1 ...

Page 5: ...ings and comfort temperature Thermostat offers also special time modes 24h SAVINGS whole day the savings temperature mode is enabled 24h COMFORT whole day the comfort temperature mode is enabled UN TIMED thermostat does not react on time changes and regulates only according to manually set requested temperature User have possibility lock keys against the unauthorized manipulation Service menu is p...

Page 6: ... changes 4 or 6 and number of days in the week is defined by setting in service menu Setting of third time change to comfort temperature Time is set by arrow keys in step of 10 minutes Button OK confirms the time and jump to another time change to savings temperature Number of changes 4 or 6 and number of days in the week is defined by setting in service menu Time setting Time is in 24 00 format B...

Page 7: ...rature 2 2 3 Time program setting Press key Menu until the following screen with symbol for first time change on comfort temperature appears By cursor key set requested time of change setting with stop of 10 minutes By pressing key OK confirm the time Second time of change on savings temperature will appear symbolized by Setting the time is the same as for first change Follow the same procedure un...

Page 8: ...y authorized person Access to service menu is recommended to be protected by password Symbol Meaning Maximum floor temperature settings Only in case that floor sensor is configured Temperature sensor configuration F floor sensor A air sensor FA floor and air sensor TIMED UNTIMED mode If set value t timed 1 thermostat uses time programs If set value t untimed 0 thermostat ignores time programs and ...

Page 9: ...wo screws it is possible push out the controlling part from the supply part On the bottom side of the control part is DIL switch with following functions FLOORS TILE WOOD 35 C 28 C Maximum predefined floor temperature 35 C for tile wood position OFF or maximum predefined floor temperature 28 C for wooden floor position ON AIR SENS Air sensor is enabled ON disabled OFF GMT 1hr at position ON Adds 1...

Page 10: ...me change on comfort temperature 6th time change on savings temperature Monday Tuesday Wednesday Thursday Friday Saturday Sunday Comfort temperature mode Savings temperature mode Time setting Date setting Manual change of requested temperature Air temperature Floor temperature Heating Freezing protection temperature activated Discharged battery warning 5 Floor sensor temperature scales In the serv...

Reviews: