background image

Magnetics that count

BOGEN Magnetics GmbH

 · Potsdamer Straße 12 - 13 · 14163 Berlin · Germany 

Fon +49 (0) 30 81 00 02 - 0 · Fax +49 (0) 30 81 00 02 - 60 · magnetics@bogen-magnetics.com · www.bogen-magnetics.com

AKS17 ins

tallation and oper

ation ins

truction manual Re

v 1.4 (2021/06/16)

1/14

Content

Safety Instructions 

 

2

Electromagnetic Compatibility 

 

3

Intended Use   

3

Function and Properties 

 

3

Assembly and Installation 

 

4

Programming Device   

4

Configuring the AKS17 Sensing Head  

6

Protocol Data Packet Information 

 

8

Offset Compensation   

9

Serial Port Signal Trigger 

 

9

Tips on the Software and Calibration  

10

Commissioning  

10

Maintenance  

10

Appendix  

11

EU Declaration of Conformity  

14

AKS17 
Absolute Magnetic Sensing Head

Installation and Operating Instructions

Summary of Contents for AKS16

Page 1: ...ntent Safety Instructions 2 Electromagnetic Compatibility 3 Intended Use 3 Function and Properties 3 Assembly and Installation 4 Programming Device 4 Configuring the AKS17 Sensing Head 6 Protocol Data...

Page 2: ...ems such as airplanes etc Risk of pinching There is a risk of getting pinched between the sensing head and the magnetic tape This can lead to injury or mechanical damage Avoid getting with your limbs...

Page 3: ...f magnetic scales and sensing heads capable of non contact position detection for linear and rotary applications Fields of deployment capital equipment automation medical engineering electrical engine...

Page 4: ...all or vice versa is a count for the period counter up down counter If signal A is preceding signal B the counter increases If signal B is preceding signal A the counter decreases The Z pulse appears...

Page 5: ...re the parameters of an AKS17 sensing head can be changed for a successful calibration The software sets the sensing head parameters for the correct master nonius periods 128 127 120 256 255 240 512 5...

Page 6: ...tory on your Windows PC To install the driver execute the specific program USB_Adapter_00052040_Driver exe Connecting the device for the calibration setup Mount the sensing head correctly per mechanic...

Page 7: ...OGEN calibration software AKS16 and AKS17 CalibrationGUI Choose AKS17 from the Sensor combo box Choose the desired sensor parameters see technical data sheet for full listing of sensor parameters Plea...

Page 8: ...scale or both if needed In case of linear calibration the user will be prompt with the countdown window on every iteration The user has to move the magnetic target during the calibration process In l...

Page 9: ...circle is red and in the textbox to the right the user can see the corresponding error message 3 Nonius calibration Max and Min represent the maximum and minimum percentage value from result regardin...

Page 10: ...ion to be 1050 Ticks Now the user can enter 239194 Current Position Resolution mod Resolution in the Desired Offset and then click Set The software automatically calculates the smallest possible offse...

Page 11: ...The sensor should be connected to the PC before saving or loading configurations The connected sensor serial number the product order code and parameter descriptions can be found under Help then Prod...

Page 12: ...er can freely disconnect the cables and reconnect a new sensor if desired Q How can I choose calibration duration A Calibration duration represents a time variable The duration should cover at least f...

Page 13: ...e it is recommended to repeat the calibration with higher velocity or higher duration and cover all the scale Calibration failed invalid calibration data cycle count Very noisy environment Please make...

Page 14: ...manual Rev 1 4 2021 06 16 14 14 EU Declaration of Conformity Acc to EU regulation for Electromagnetic Compatibility 2004 108 EU European Standard for Electromagnetic Compatibility EN 61326 1 2006 EMC...

Reviews: