background image

Page 

1

 of 

12

 Rev 03

 

 

 

Instructions manual for the automatic humidifier 

SIRIO

 

 

 

 

 

1 – Warnings for safe utilisation 

 

When using electrical appliances it is always required to adhere to some basic safety precautions, including the following:

 

1.

 

READ THE INSTRUCTIONS IN THEIR ENTIRETY.

 

2.

 

Use the appliance only with electrical system features complying with the label affixed on the appliance and with this 
manual.

 

3.

 

Do not place

 

the unit close to heat sources and do not cover it with other objects.

 

4.

 

Do not leave the appliance unattended for long periods of time when it is connected to the power mains. Do not use the 
appliance with damaged cables or plugs, or appliances that have been dropped to the ground or damaged in some way. 
Consign the appliance to the nearest authorised service centre requesting its inspection, or repair.

 

5.

 

Use of accessories not recommended or not sold by the manufacturer is forbidden.

 

6.

 

Do not use outdoors.

 

7.

 

The appliance can be used by children under 12 years of age and/or persons with reduced physical or mental capacity, or 
without experience or the necessary knowledge, as long as supervised by an adult or after they have received instructions 
related to safe appliance use and understand the dangers related to it. The same is true for cleaning and maintenance.

 

8.

 

Always start use by verifying the feeder conditions, therefore connect it to the power outlet. To remove it, detach it from 
the power outlet.

 

9.

 

Disconnect the feeder from the power outlet when the appliance is not running. 

 

10.

 

The feeder must be placed so it is easy to access when it is necessary to disconnect it from the power mains.

 

11.

 

To disconnect the feeder, grab it directly (not the cable) and detach it from the wall outlet.

 

12.

 

Any  modification  to  this  product  that  has  not  been  expressly  authorised  by  the  manufacturer,  besides  representing  a 
safety risk, will void the warranty.

 

13.

 

STORE THESE INSTRUCTIONS WITH CARE.

 

 

 

Translation of original instructions

 

 

 

Summary of Contents for SIRIO

Page 1: ...by the manufacturer is forbidden 6 Do not use outdoors 7 The appliance can be used by children under 12 years of age and or persons with reduced physical or mental capacity or without experience or the necessary knowledge as long as supervised by an adult or after they have received instructions related to safe appliance use and understand the dangers related to it The same is true for cleaning an...

Page 2: ... 6 3 Sensor positioning 7 7 Using SIRIO during incubation 9 8 Using SIRIO during hatching 10 9 Humidity parameters for incubation 10 10 Using SIRIO with other brand incubators 11 11 SIRIO maintenance and cleaning 11 12 Disposal 11 13 Warranty after sale service 12 Electronic format copy of this instructions manual can be downloaded from the site www borotto com or can be requested by writing to th...

Page 3: ...mal eggs specifically hen pheasant turkey guinea fowl quail grey partridge partridge goose muscovy common wild duck peacock rock partridge pigeon Virginia quail exotic birds and birds of prey The following declaration of conformity is issued under the manufacturer s exclusive responsibility And it conforms to the following directives Directive EN 61326 1 2007 Directive EN 61010 1 2010 Directive EN...

Page 4: ...ower supply Positive polarity at the centre of the power supply connector 3 Identification plate The equipment is fitted with an identification plate showing the equipment s identification details and the main technical specifications SIRIO automatic humidifier Year XXXX Code SIRIO Portata 0 5 l h ca Bar 0 2 Serial Number XXXX Weight Kg 0 435 Classe II Imput voltage 12 V DC MAX Power 4W Made in It...

Page 5: ...ent with the technical and safety specifications of the equipment and for the manual refilling of water inside an incubator machine making it possible to automatically maintain the set humidity rate 5 Technical features and specifications Equipment model SIRIO SIRIO Power supply voltage 12V DC Maximum absorbed power 4 W Average daily consumption 1 Wh Feeder power supply voltage already included 10...

Page 6: ...objects between the product and the plane for example tablecloths or covers Position SIRIO next to the incubator placing a water container nearby Any container can be used bottle canister etc as long as it is clean inside Dirty containers may result in the development of bacterial flora during incubation causing the death of the embryo Insert the suction pipe the one connected to the rubber holdin...

Page 7: ...tone remove it with anti scaling agent before inserting the valves 6 3 Sensor positioning Insert the humidity sensor inside the incubator positioning it above the flap in the corner use a minimum amount of pressure to ensure blocking The sensor cable must remain resting on the flat side on the edge of the incubator as shown in the photo It is a special anti crushing cable therefore it will not be ...

Page 8: ...Page 8 of 12 Rev 03 Position the humidity sensor on the opposite side of the incubator compared to the filling nozzles DO NOT PLACE THE SENSOR ABOVE THE WATER INLET TANKS REAL 12 REAL 24 ...

Page 9: ...er H on the display From this moment SIRIO starts working by pumping water inside the incubator when necessary making a rotating symbol appear on the display In other moments the appliance remains in standby SIRIO is programmed to inject small drops of water little by little in order to allow the evaporation which determines the environment required relative humidity Upon start up it will require ...

Page 10: ... not compromise the result In fact the first chick births since they are wet will cause a quick increase of the relative humidity level ATTENTION Do not incubate with the environment temperature below 20 C Below this value the temperature of the plastic bottom of the incubator cold does not allow the water to evaporate SIRIO then continues to pump water into the incubator unnecessarily flooding it...

Page 11: ...ately 15 minutes recovering and disposing of the pumped aqueous solution leave the pump running dry for another 15 minutes We recommend using bleach since it destroys the bacterial flora and any residue does not damage the embryos under development DO NOT USE ANY OTHER CHEMICAL SUBSTANCES FOR CLEANING AND SANITISING SIRIO FOR ANY REASON With variable frequency depending on hardness of the water us...

Page 12: ...ot authorised by the Manufacturer force majeure earthquakes floods fires etc Only use the appliance for the purpose it is intended for uses other than those indicated in these instructions shall be deemed as hazardous and the Manufacturer disclaims any and all liability for any damage to persons animals or property arising from failure to comply with this warning The Manufacturer shall not be deem...

Reviews: