background image

BioEntry Plus

ARD-FPBEPPR-OC | ARD-FPBEPHP-OC 
ARD-FPBEPIC-OC | ARD-FPBEPMF-OC

en

Installation manual

Summary of Contents for ARD-FPBEPHP-OC

Page 1: ...BioEntry Plus ARD FPBEPPR OC ARD FPBEPHP OC ARD FPBEPIC OC ARD FPBEPMF OC en Installation manual ...

Page 2: ......

Page 3: ...gerprint recognition 6 3 How to place a finger 7 4 Product Contents 9 5 Description 12 6 Product Dimension 15 7 Cables and Connectors 16 8 Installation of Wall mount Bracket 18 9 Connections 19 9 1 Power Connection 19 9 2 Ethernet Connection 19 9 3 RS485 Connections 20 9 4 Relay Connection 22 9 5 Digital Input Connection 23 9 6 Wiegand I O Connection 23 ...

Page 4: ... 1 1 2010 10 Installation manual Bosch Access Systems GmbH 10 Network Default Setting 24 11 Installation References 25 12 Electrical Specification 27 13 Troubleshooting 28 14 Device Cleaning 29 15 FCC Rules 30 16 Specifications 31 Index 32 ...

Page 5: ...evice Do not place the device next to heating equipments Be careful not to let liquid like water drinks or chemicals leak inside the device Clean the device often to remove dust on it In cleaning do not splash water on the device but wipe it out with smooth cloth or towel Do not drop the device Do not damage the device Do not disassemble repair oralter the device Do not let children touch the devi...

Page 6: ...ng skin in a fingerprint while valley is a hollow between two ridges Each individual has different pattern of ridges and valleys and finger recognition makes use of such originality and uniqueness of these patterns Fingerprint sensor generates 2 dimentional fingerprint image using different technology According to the sensing technology fingerprint sensors are classified into optical capacitive or...

Page 7: ...ttle finger is relatively more difficult to place in a correct position How to place a finger on a sensor Place a finger such that it completely covers the sensor area with maximum contact Place core part of a fingerprint to the center of a sensor People tend to place upper part of a finger The core of a fingerprint is a center where the spiral of ridges is dense Usually core of fingerprint is the...

Page 8: ...s scan after wiping them off If a finger is way too dry place after blowing warm breath on the finger tip Tips for fingerprint enrollment In fingerprint recognition enrollment process is very important When enrolling a fingerprint please try to place a finger correctly with care In case of low acceptance ratio the following actions are recommended Delete the enrolled fingerprint and re enroll the ...

Page 9: ...BioEntry Plus Product Contents en 9 Bosch Access Systems GmbH Installation manual V 1 1 2010 10 4 Product Contents Basic Contents BioEntry Plus Wall mounting metal bracket ...

Page 10: ...duct Contents BioEntry Plus V 1 1 2010 10 Installation manual Bosch Access Systems GmbH Wall mounting screws 2 ea Star shaped screws Star shaped small wrench Software CD 3 pin 4 pin 5 pin 7 pin cables each 1 ea ...

Page 11: ...oEntry Plus Product Contents en 11 Bosch Access Systems GmbH Installation manual V 1 1 2010 10 Optional accessories Secure I O 12V power adaptor Plastic stand USB fingerprint scanner for enrollment on PC ...

Page 12: ...D Status per Color 1 RF card reading part Place an RF card over the picture 2 LED Displays current status using seven different colors 3 Fingerprint sensing part Place a finger on a sensor surface Color Mode Description Green constant Authorization Success Red constant Authorization Fail Pink constant On Processing ...

Page 13: ...lue red alternating 2 sec Initialized time due to the internal battery discharge blue yellow alternating 2 sec DHCP fail red blinking 2 sec Failed Please contact to your distributor or Bosch yellow blinking 2 sec Waiting for input yellow blinking 1 sec Receiving IP address from DHCP server 1 Star shaped screw hole for fixing a body to a metal bracket Color Mode Description ...

Page 14: ...H Back 1 3 pin connector wiegand input or ouput 2 5 pin connector power and RS485 3 4 pin connector ethernet TCP IP 4 7 pin connector digital input and relay output 5 DIP switch RS485 termination setting Section 9 3 RS485 Connections Network default setting Section 10 Network Default Setting ...

Page 15: ...BioEntry Plus Product Dimension en 15 Bosch Access Systems GmbH Installation manual V 1 1 2010 10 6 Product Dimension Front Side Metal bracket unit mm ...

Page 16: ...ual Bosch Access Systems GmbH 7 Cables and Connectors Power and RS485 TCP IP Pin Pin description Wire 1 Power 12V red 2 Power GND black 3 RS485 GND gray 4 RS485 TRx blue 5 RS485 TRx yellow Pin Pin description Wire RJ45 Pin 1 Tx yellow 6 2 Tx green 3 3 Rx red 2 4 Rx black 1 ...

Page 17: ...In output Switchable Digital Inputs and Relay output Pin Pin description Wire 1 Wiegand Data 0 green 2 Wiegand Data 1 white 3 Wiegand GND black Pin Pin description Wire 1 SW1 input yellow 2 SW1 GND black 3 SW2 input green 4 SW2 GND black 5 Relay normal close orange 6 Relay common blue 7 Relay normal open white ...

Page 18: ... Access Systems GmbH 8 Installation of Wall mount Bracket Step 1 Step 2 Step 3 Step description Step 1 Fix wall mount bracket on a wall using wall mounting screws 1 Step 2 Hook BioEntry Plus on the wall mount bracket Step 3 Fix BioEntry Plus and wall mounting bracket using a star shaped screw 2 ...

Page 19: ...anual V 1 1 2010 10 9 Connections 9 1 Power Connection Recommended power supply 12V 10 at least 500mA Comply with standard IEC EN 60950 1 To share the power with other devices use a power supply with higher current ratings 9 2 Ethernet Connection Ethernet Connection via HUB ...

Page 20: ...a straight CAT 5 cable As the BioEntry Plus supports auto MDI MDIX feature it is not necessary to use a crossover type cable 9 3 RS485 Connections RS485 Connection for Host Communication 1 Only the devices at the both ends of the bus should be terminated To enable termination on the RS232 485 converter refer to the converter s manual 2 Disable termination 3 The stubs should be as short as practica...

Page 21: ...y to lower the baudrates The GND signal may be omitted if and only if the GND potential difference is less than 5V 1 Only the devices at the both ends of the bus should be terminated To enable termination on the RS232 485 converter refer to the converter s manual 2 The stubs should be as short as practical NOTICE Maximum number of devices in an RS485 loop is eight 8 including Host PC or Host devic...

Page 22: ...n Connections BioEntry Plus V 1 1 2010 10 Installation manual Bosch Access Systems GmbH 9 4 Relay Connection Relay Connection Fail safe lock Relay Connection Fail secure lock Relay Connection Automatic door ...

Page 23: ...3 Bosch Access Systems GmbH Installation manual V 1 1 2010 10 9 5 Digital Input Connection Digital Input Connection RTE Door sensor Digital Input Connection Alarm Emergency sw 9 6 Wiegand I O Connection Wiegand Input Wiegand Output ...

Page 24: ...ow How to initialize Network Setting 1 Turn off BioEntry Plus power 2 Please make DIP SW 2 ON Please refer to figure1 3 After turning on BioEntry Plus power user can modify TCP IP or RS 485 setting what user wants Network default settings TCP IP address 192 168 0 1 Not checked Use server RS485 PC connection 115200bps 4 Please modify TCP IP or RS 485 setting and save it 5 Please make DIP SW 2 OFF P...

Page 25: ...s en 25 Bosch Access Systems GmbH Installation manual V 1 1 2010 10 11 Installation References Installation Reference 1 Stand alone 1 Power supply 2 Door lock 3 Exit button 4 Door sensor 5 PC with Bio application via LAN 6 Enroll scanner ...

Page 26: ...ion manual Bosch Access Systems GmbH Installation Reference 2 Secure 1 Power supply 2 Door lock 3 Exit button 4 Door sensor 5 Wiegand or RS485 secure communication 6 AMC2 4W or 4R4 or Secure I O 7 Access control system 8 PC with Bio application via LAN 9 Enroll scanner ...

Page 27: ... adapter only Current mA 250 Switch Input VIH V TBD VIL V TBD Pull up resistance Ω 4 7k The input ports are pulled up with 4 7k resistors TTL Wiegand Output VOH V 5 VOL V 0 8 Pull up resistance Ω 4 7k The output ports are open drain type pulled up with 4 7k resistors internally Relay Switching capacity A 1 0 3 30 V DC 125 V AC Switching power resistive 30 W 37 5 VA DC AC Switching voltage V 110 12...

Page 28: ...y Fingerprint is entered but authorization keeps failing Check whether the user is restricted by door zone or time zone Inquire of administrator whether the enrolled fingerprint has been deleted frin the device for some reason Authorized but door is not opened Check whether the time is set as lock time Check whether an antipass back mode is in use In antipass back mode only who entered can exit De...

Page 29: ... 10 14 Device Cleaning Wipe out machine surface with dry towel or cloth In case there is dust or impurities on the sensor of the BioStation wipe off the surface with dry towel Note that if the sensor is cleaned by detergent benzene or thinner surface is damaged and fingerprint can t be entered ...

Page 30: ...l device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates user and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guaranteee that interferen...

Page 31: ...og capacity 50 000 events Matching speed Less than 1 second Operation mode Fingerprint RF Card RF Card Fingerprint Network interface TCP IP Internal relay Deadbolt EM lock door strike automatic door TTL I O 2 inputs for exit switch and door sensor Wiegand I O 1 Port Wiegand input or output is used according to the configuration Sound and interface Multi color LED and multi tone buzzer Rated voltag...

Page 32: ...32 en Specifications BioEntry Plus V 1 1 2010 10 Installation manual Bosch Access Systems GmbH ...

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ...Bosch Access Systems GmbH Charlottenburger Allee 50 D 52068 Aachen Germany www boschsecurity com Bosch Access Systems GmbH 2010 ...

Reviews: