Page 1: ...TDL Freight Guard TDL140 Operating Instructions ...

Page 2: ...Introduction 3 2 Quick Start Guide 4 3 Mounting the Transport Data Logger TDL140 5 4 Package Contents 6 5 Technical Specifications 7 6 Management and Monitoring of Devices 8 7 Safety and Environment Regulatory Notices 8 2 ...

Page 3: ... shipments and goods in transit for creating customer trust with reliable information in every transportation mode Reduce com plexity with the Bosch TDL Freight Guard End to End solution by being active informed about the shipment status While transportation the device operates in sleep mode and monitors the environmental conditions TDL Freight Guard TDL140 is a self sustainable unit capable of op...

Page 4: ...attery status press the On Off button LED will switch on green for full battery and red for battery under 95 To force communication to Cloud application press long the On Off button until white LED is switched On 1 The the LED will blink green until the unit successfully sends a message or 5 minutes have passed 2 The LED will blink red until the unit successfully finds the GPS position or 5 minute...

Page 5: ... require ments can be carried out with screws or with double sided adhesive tape In case shock shall be measured a direct and non absorbing connection between the mounted TDL140 and the monitored goods is required For achieving this we recommend using either screws or a fiber reinforced adhesive tape Recommended screws M4 recommended with washer raised cheese head pan head round head screws Recomm...

Page 6: ...4 Package Contents Mounting plate for TDL Freight Guard TDL140 TDL Freight Guard TDL140 unit TDL Freight Guard TDL140 charging cable Recommended charger Input 100 240 VAC 50 60Hz Output 5V 2A 1 2 3 6 ...

Page 7: ...LONASS Geofencing Cellular location Cellular communication 2G GSM GPRS EDGE 850MHz 900 MHz 1800 MHz 1900 MHz 3G UMTS HSDPA HSUPA 800 MHz 850 MHz 900 MHz 1900 MHz 2100 MHz Radio power Max 33dBm for GSM GPRS and 24dBm for UMTS HSPA Message GPRS TCP IP over PPP Flight mode Automatic non hermetic packaging Firmware update FOTA Enclosure protection class IP 64 Note IP64 rating only when provided USB pr...

Page 8: ...he TDL140 to create one Visit www bosch connectivity com to get complete user manual for Cloud application 7 Safety and Environment Regulatory Notices CAUTION Lithium Battery The device contains a lithium battery Handling the battery incorrectly could cause fire Read and follow the valid transportation regulations Do not replace the battery CAUTION Opening the Casing without Authorization Opening ...

Page 9: ... text of the EU declaration of conformity is available at the following internet address www bosch connectivity com tdl140 Operating the device in airplanes TDL Freight Guard TDL140 has a flight mode detection to suspend active communication over the cellular network during flight Validate that the used air carrier s regulation allows the unattended use of an activated TDL Freight Guard TDL140 dur...

Page 10: ...shall not be held liable for any damages resulting from any use of the TDL140 outside beyond the certified types of operation and or defined field of application Radiofrequency radiation exposure information this equipment complies with the radiation exposure limits prescribed for an uncontrolled environment for fixed and mobile use condi tions This equipment is not designed as a portable cellular...

Page 11: ...interference and 2 this device must accept any interference received including interfer ence that may cause undesired operation The user shall not modify the device The grantee is not responsible for any changes or modifications not expressly approved by the party re sponsible for compliance Such modifications may void the FCC authorization to operate this equipment 11 www bosch connectivity com T...

Page 12: ...Bosch Connected Devices and Solutions GmbH Ludwig Erhard Straße 2 72760 Reutlingen Germany bosch connectivity com ...