background image

Boss Water Systems 

Australia 

Reverse Osmosis System 

 

Model – 021-4P-GM 

Congratulations on your purchase of the 
most advanced water purifier system 
available! 

 

 

 

Installation and Service Guide short web version, 
this is not the instruction manual you will receive 

with your purchase of a PSI-021-4P-GM but a 
shortened version that is available on our web site, 
it is a shorter version due to other suppliers likely to 
copy this instruction manual as their own. 

 
This reverse osmosis system is designed for those persons that want to self maintain the system and 
using the extra equipment supplied with this unit analyse how the system is operating. 
The gauges measure the mains water pressure (bottom Gauge), the top gauge measures the pressure 
after the water has passed through the two primary cartridges. The sediment from the mains builds 
up on the cartridges and will start to slow the flow rate through the primary cartridges, this pressure 
drops the pressure and this is shown on the top gauge, by noting the pressure difference between the 
two gauges indicates the level of pressure drop. 
The total dissolved solids (TDS) meter supplied with the unit measures the success level of the 
membrane in parts per million TDS, this is an electronic devise and is simple to use, you fill a clean 
glass with tap water and take a reading, then fill the glass with reverse osmosis water and take a 
reading, the difference between the two readings gives you the success rate. The reverse osmosis 
systems are very reliable, the TDS meter is really to re-assure all is working well. 

Summary of Contents for 021-4P-GM

Page 1: ...essure bottom Gauge the top gauge measures the pressure after the water has passed through the two primary cartridges The sediment from the mains builds up on the cartridges and will start to slow the flow rate through the primary cartridges this pressure drops the pressure and this is shown on the top gauge by noting the pressure difference between the two gauges indicates the level of pressure d...

Page 2: ... waste as such the reverse osmosis process is a selection process if the water molecule is pure it will pass into the pure water part anything else is rejected The reverse osmosis process is the best water purity of any type of process and is similar to Distillation but distilled water is almost devoid of oxygen and tastes flat and dead reverse osmosis water process actually adds oxygen to the wat...

Page 3: ...ressure Gauge to measure pressure After the two pre filters Stage 1 Sediment pre filter this filter is a 1 micron polyspun sediment filter cartridge for mechanical removal of Grit dust Rust mud algae ect This cartridge is normally replaced every 12 months but if dirty mains water is encounted more frequent change may be required Stage 2 Carbon pre filter this filter is a high grade chloramine carb...

Page 4: ...lter system a back corner cupboard is often used the tank tube line is 1 8 metres try to have as short a tube to the tank and faucet as practicable because the shorter the tube the faster the flow will be All tube is colour coded for installation ease Blue tube connects from the mains supply to the entry point of the unit Yellow tube connects the main filter unit to the storage tank The black line...

Page 5: ... threaded part of the faucet push it in firmly about and slide nut up to thread and tighten firmly do not over tighten Storage Tank Place storage tank in a convenient position Tank can be placed on its stand either upright or on its side Activating the System For the First Time First open the Faucet turn Feed Water Valve counter clockwise until fully open Check plumbing kit assembly for leakage Ma...

Page 6: ... do this will shorten membrane life This flush valve needs to be operated when the tank is filling if you open the valve and nothing happens the system is in shut down mode release some water from the faucet to start the unit filling again and open the flushing valve again Drain the tank as part of the membrane flushing process When this valve is in the closed position it operates as a flow restri...