background image

1

Instruction Manual

 

TPSE201 (181422) - BOSS

TM

 Universal Programmer

TPSE101 (569565) - BOSS

TM

 Universal Timeswitch

Thank you for purchasing this product. If installing for someone else, please ensure that the 
instructions are handed to the householder.

Please read this manual prior to installation or use. Retain for future reference.

Always isolate the mains supply before removing the unit from the backplate.

Please leave these instructions with the end user where they should be kept in a safe place for 
future reference

Installation

The TPSE201/TPSE101 is easily installed using the backplate supplied. This can be mounted directly to 
the wall or a single gang recessed box using the holes provided; cable entry is from the rear.

Specification

Power supply 

230V/50Hz

Switch rating

6(2)A

Switch type

Single pole, double throw (SPDT)

Operating temperature

0°C - 50°C

Storage conditions

-20°C - 60°C

Frost protection temperature

5°C

Programme

5/2, 7 day or daily selectable by jumper 
3 setting per day

Time display

12 or 24 hour

Memory

Internal memory back-up

Backlight

Green LED

Switches/Jumpers

The installer should select the jumper positions required if changing from the factory pre-sets, these 
jumpers are found on the rear of the unit. Always enable the internal memory back up battery before 
installing the unit, 

Switch/Jumpers

Function

Program type

3x2 pins jumpers for 5+2 days (factory default setting), 
7 days program or daily

P/G (TPSE201 only)

3x1 pin jumper for fully pumped and controlled system 
(factory default setting) or gravity-fed hot water system.

Internal backup battery

3x1 pin jumper to enable/disable the internal backup 
battery (disabled is the factory default setting)

Summary of Contents for TPSE101

Page 1: ...on Power supply 230V 50Hz Switch rating 6 2 A Switch type Single pole double throw SPDT Operating temperature 0 C 50 C Storage conditions 20 C 60 C Frost protection temperature 5 C Programme 5 2 7 day or daily selectable by jumper 3 setting per day Time display 12 or 24 hour Memory Internal memory back up Backlight Green LED Switches Jumpers The installer should select the jumper positions require...

Page 2: ... of circuit earth wires only 8 The backplate has 6 holes through which to fix to the surface of your choice Please note that when fitting the controller to the backplate some pressure downwards is required to lock the pins in the unit to the connectors in the backplate Secure the controller to the backplate with the captive screws at the bottom taking care not to over tighten 9 Enable the memory b...

Page 3: ...ternal Wiring Wiring diagrams TPSE201 Alternative wiring connections for other BOSSTM room thermostats Wireless thermostat receiver unit MUST have permanent mains power from fused spur to operate correctly ...

Page 4: ...tral Heating Adv CH Advance to next program for Central Heating Mode HW Only for TPSE201 Operating mode selection for Hot Water Hr HW Only for TPSE201 Temporary override for Hot Water Adv HW Only for TPSE201 Advance to next program for Hot Water Increase set Temperature Decrease set Temperature Turn on backlight for 10 seconds Activate de activate holiday override Set Press to begin confirm progra...

Page 5: ...M indicator N A Date 2016 Jan 1 Daylight Saving On Program Default factory setting Program Number indicator Depends on program SET indicator Off PROG indicator Off Mode indicator s Auto CH HW indicator s Depends on program Output Relay Depends on program After reset the TPSE201 TPSE101 will operate in Auto mode Default Program Settings after reset Same for both 5 2 and 7 days programmes Program Ou...

Page 6: ...ly Press and release Select press or to increase or decrease the minute respectively Press and release Select to set the Year y xx is displayed press or to increase or decrease the year respectively The year can set between 20 16 and 20 99 inclusive Press and release Select to set the Month of Year m xx is displayed press or to increase or decrease the month respectively The month can set between ...

Page 7: ...e set between 3 00 am and 2 50 am on the next day to allow you to programme the CH HW to stay on past midnight if required The PROG display indicates the program number The CH HW display indicates whether CH or HW is being programmed No CH HW indicator is displayed in TPSE101 The selected item will be flashing and can be adjusted by or key Program time is changed in 1 minute steps Press and hold o...

Page 8: ... 1 ON hour minute Program 1 OFF hour minute Program 2 ON hour minute Program 2 OFF hour minute Program 3 ON hour minute Program 3 OFF hour minute and then cycle back to Program 1 ON Press Set at any time to confirm the setting and return for program set selection 7 days program selected Central Heating and Hot Water have independent programmes set 3 different time settings can be programmed for ea...

Page 9: ...ute Program 1 OFF hour minute Program 2 ON hour minute Program 2 OFF hour minute Program 3 ON hour minute Program 3 OFF hour minute and then cycle back to Program 1 ON Press Set at any time to confirm the setting and return to program selection Daily program selected Central Heating and Hot Water have independent programmes 3 different time settings can be programmed for all days Total 3 settings ...

Page 10: ...s to be reviewed or adjusted in the sequences below Program 1 ON hour minute Program 1 OFF hour minute Program 2 ON hour minute Program 2 OFF hour minute Program 3 ON hour minute Program 3 OFF hour minute and then cycle back to Program 1 ON Press Set at any time to confirm the setting and return to program selection Operating Mode Selection In normal operating mode press Mode to step through the f...

Page 11: ...ce Auto On Once Auto Off On Once Auto Off In a poorly controlled gravity circulation hot water system whenever the boiler comes on to service the heating there will inevitably be some circulation though the hot water storage tank which will then heat up Therefore whenever the HEATING is ON the HOT WATER is also ON It is therefore NOT possible to have independent programmes for heating and hot wate...

Page 12: ...entral heating and or h1 is displayed on the right side for hot water For TPSE101 1h is displayed on the right side only For TPSE201 with P selected for hot water press Hr to activate the Hr program override For TPSE201 with P selected for central heating press Hr to activate the Hr program override For TPSE201 with G selected for central heating press Hr to activate the Hr program override For TP...

Page 13: ...yed with the Mode indicator s flashing to indicate that the override mode is activated CH or HW with override activated will return to the previous operating mode at the end of the set duration and the corresponding Mode Indicator will stop flashing When the Hr Program Override mode is activated and the clock is displayed press Hr to review the current settings SET is displayed but there is no cha...

Page 14: ... program 1 On to Program 3 Off 06 00 turn on 22 00 turn off Now user presses Hr twice to begin 2 hours boost mode Now the Once program will extend 2 hours i e turning off is delayed from 22 00 to 24 00 3 In Off mode The clock is at 11 00 No channel is on The user presses Hr twice to begin 2 hours boost mode Now the channel is turned on and will remain on for 2 hours i e the relay is turned on at 1...

Page 15: ...reaches start time of Program2 On Now the relay is kept On but ADV icon is NOT shown i e Advance override is finished 2 In Once mode Case 1 Device is in channel ON state At 11 00 device is in Program 2 On and the channel is ON The user presses Adv The relay switches OFF and the ADV icon is shown At 22 00 the relay is kept OFF but the ADV icon is NOT shown i e Advance override is finished At 06 00 ...

Page 16: ...s to start counting down SET will disappear and both CH and HW will be turned off immediately Press for 3 seconds again to de activate the Holiday Override mode The Programmer returns to the normal mode The Programmer counts each pass through midnight as a day LCD Backlight LCD backlight is activated when or any key is pressed The backlight will be turned off 10 seconds after the last key press LC...

Page 17: ...out mains power should last up to one year If the time and date need to be reset after a power failure this is an indication that the battery needs to be replaced To replace the battery open the back of the Thermostat case using a screw driver Remove the screw marked by a red tab see image and carefully lift off the top circuit board Remove the old battery from its clip Insert a new battery type C...

Page 18: ...ation LED output indicator is illuminated whenever the output is on TPSE101 TPSE201 BOSS is a registered trademark of the Travis Perkins Group Registered Office Travis Perkins plc Lodge Way House Lodge Way Harlestone Road Northampton NN5 7UG ...

Reviews: