Instruction Manual
TPSE201 (181422) - BOSS
TM
Universal Programmer
TPSE101 (569565) - BOSS
TM
Universal Timeswitch
Thank you for purchasing this product. If installing for someone else, please ensure that the
instructions are handed to the householder.
Please read this manual prior to installation or use. Retain for future reference.
Always isolate the mains supply before removing the unit from the backplate.
Please leave these instructions with the end user where they should be kept in a safe place for
future reference
Installation
The TPSE201/TPSE101 is easily installed using the backplate supplied. This can be mounted directly to
the wall or a single gang recessed box using the holes provided; cable entry is from the rear.
Specification
Power supply
230V/50Hz
Switch rating
6(2)A
Switch type
Single pole, double throw (SPDT)
Operating temperature
0°C - 50°C
Storage conditions
-20°C - 60°C
Frost protection temperature
5°C
Programme
5/2, 7 day or daily selectable by jumper
3 setting per day
Time display
12 or 24 hour
Memory
Internal memory back-up
Backlight
Green LED
Switches/Jumpers
The installer should select the jumper positions required if changing from the factory pre-sets, these
jumpers are found on the rear of the unit. Always enable the internal memory back up battery before
installing the unit,
Switch/Jumpers
Function
Program type
3x2 pins jumpers for 5+2 days (factory default setting),
7 days program or daily
P/G (TPSE201 only)
3x1 pin jumper for fully pumped and controlled system
(factory default setting) or gravity-fed hot water system.
Internal backup battery
3x1 pin jumper to enable/disable the internal backup
battery (disabled is the factory default setting)