background image

B4-1KB 

B4-1KB

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UPS + AVR 

Uninterruptible Power System 

 

T HE BRITISH 

POWER CONVERSION 

COMPANY

 

 

User’s Manual 

 

 

 

PowerStar Series 

(1200/1700/2200) 

 

 

 

 

 

 

 

 

 

 

100%

80%
60%
40%
20%

Replace Battery 

A l a r m   O f f  
C h a r g i n g  

B u c k  ?  

Boost  ?  

BATTERY LEVEL 

SPECIAL STATUS 

NORMAL 
BACK UP 
LOW BATT.  
OVER LOAD

 

Summary of Contents for PowerStar series 1200

Page 1: ...uptible Power System THE BRITISH POWER CONVE RSIONCOMPANY User s Manual PowerStar Series 1200 1700 2200 100 80 60 40 20 Replace Battery Alarm Off Charging B u c k Boost BATTERY LEVEL SPECIAL STATUS NORMAL BACK UP LOW BATT OVER LOAD ...

Page 2: ...ge 5 4 INSTALLATION AND OPERATION Page 5 6 4 1 Installation 4 2 Operation 4 3 Audible alarm 5 INDICATION AND CONTROL Page 7 8 5 1 Battery level LEDs 5 2 Special status LEDs 5 3 Auto self test function 5 4 Status LED and Alarm indication 5 5 Reset the UPS 6 COMMUNICATION INTERFACE Page 9 7 TROUBLE SHOOTING Page 10 8 SPECIFICATIONS Page 11 9 IMPORTANT SAFETY INSTRUCTIONS Page 12 MEMO 1 ...

Page 3: ...f battery voltage level LEDs of UPS special status LED of operation status Control button 2 1 3 4 2 1 4 NORMAL BACK UP LOW BATT OVER LOAD BATTERY LEVEL SPECIAL STATUS Replace Battery Alarm Off Charging B u c k Boost 100 80 60 40 20 3 13 2 ...

Page 4: ...ated by any individuals without any previous experience The socket outlet shall be installed near the equipment and easily accessible With the installation of this equipment it should be prevented that the sum of the leakage current of the UPS an the connected consumer does not exceed 3 5mA Attention hazardous through electric shock Also with disconnection of this unit from the main hazardous volt...

Page 5: ... cm 38 x 20 x 18 44 x 20 x 18 51 x 20 x 18 SHIPPING DIM L x H x W cm 48 x 33 x 30 54 x 33 x 30 61 x 33 x 30 WEIGHT N W G W kgs 15 16 21 50 22 50 25 26 1 INTRODUCTION 1 1 Overview The PowerStar series UPS is an advanced high performance stand by Uninterruptible Power System UPS designed to protect your computer from utility line failure In the event of utility failure blackout the UPS will rapidly ...

Page 6: ...rated for at least 20 Amps Connecting your equipment to the UPS To ensure that your computer equipment will be protected during a utility failure it is important to make sure that the maximum power need of the equipment is not over the rated capacity of the UPS When blackout happens LED of operation status will become red and alarm will beep if the load is over the rated value Meantime if the over...

Page 7: ...e of self test about 3 4 sec If test results are O K the green LED will be on 4 2 2 Pushing the button for 3 seconds the UPS will turn off the power But the red LED will remain blinking when the AC power cord is connected To turn off the power completely please pull out the power cord For turning on the UPS again please connect back power cord and push the button 4 2 3 During blackout push the but...

Page 8: ... connecting a low utility voltage The loads receive normal power The Buck LED would be on when the UPS is connecting a high utility voltage The loads receive normal power 5 3 Auto self test function In normal mode of UPS turn on your computer and push the button on the front panel for self test The UPS will simulate a power outage and transfer your load to the UPS s battery If low battery warning ...

Reviews: