Page 1: ...Hardware operating instructions Version 1 2 DIGIVOTE III VD30 parliamentary TR30 ...

Page 2: ...s manual please contact Brähler ICS Konferenztechnik International Congress Service AG Auf der Alten Burg 6 D 53639 Königswinter Germany T 49 2244 930 100 E sales braehler com You will find further information about our products on the Internet at www braehler com 2009 BRÄHLER ICS AG Königswinter All rights reserved especially also partly the translation reprint reproduction through copying or oth...

Page 3: ... equipment Ventilation operate equipment with proper ventilation Avoid heat sources such as heating radiators etc Mains connection pass all power cables so that they will not be damaged Cable connections avoid trip traps Liquids avoid penetration of liquids into the housing Power sockets operate equipment only with power sockets that are connected to ground according to the relevant specifications...

Page 4: ...VD30 parliamentary TR30 DIGIVOTE III 4 Copyright by Brähler ICS ...

Page 5: ...em components 10 System components 11 Voting Unit VD30 parliamentary 11 Transponder Controller TR30 11 Installation hints 12 Short Instructions TR30 15 Short Instructions VD30 parliamentary 17 Technical data 18 Trouble shooting 20 Annex Cable diagrams 21 Connection cable PC USB Å Æ Transponder TR30 21 Connection cable PC RS232 Å Æ Transponder TR30 22 Connection diagram Wall Power supply 23 Warrant...

Page 6: ...nual Indicates an important note if not minded the functionality of the unit the security of your data or your health are put at risk Supplementary information remarks and tips follow this symbol Text which follows this symbol describes activities that must be performed in the order shown Texts in bolded letters require your special attention ...

Page 7: ... it s not used for several days To disconnect the cord pull it out holding the plug Never pull the cord itself Installation Allow proper air circulation to prevent internal heat accumulation Do not place the unit on a surface that may block the ventilation holes Do not install the unit in a location near heat sources or in a place exposed to direct sunlight excessive dust humidity mechanical vibra...

Page 8: ... it indicates important information This product is conforming to the rules of the following European directive 73 23 EEC 2004 108 EC and 99 5EC The warranty will expire if you cause defectives by inappropriate use or handling of the unit Although DIGIVOTE is a simple and reliable system it is recommended that the BRÄHLER ICS advisory service is consulted for planning installation and commissionin...

Page 9: ...e game shows The system offers both traditional voting modes like yes no abstain or for against using a variety of parliamentary rules and differentiated opinion formers The real strength of the DIGIVOTE III is its interaction capability For example the speaker can actively include his listeners in the presentation Surveying particular listener information can locate target groups or set focal poi...

Page 10: ...E voting system also may contain the following components Wireless voting unit VD30 parliamentary to participate in voting TK50 DVIII Storage and charging tray for 50 voting units VD30 parliamentary Transponder TR30 controller for voting procedure DIGIVOTE III Software Diverse cables also for multi transponder mode ...

Page 11: ...an respond to radio communication can be checked for battery status and e g be set all at once to a different radio channel for the next event which is much more convenient than doing this individually one by one Transponder Controller TR30 The transponder TR30 processes all DIGIVOTE III VD30 parliamentary voting units responses and communicates these to the PC software It handles more than 10 000...

Page 12: ...argeable battery respectively The connection of the power supply is done by a XLR connector lockable VD30 parliamentary voting unit TK50 DVIII Charging and storage tray Video Projector VD30 parliamentary voting unit VD30 parliamentary voting unit VD30 parliamentary voting unit or RS232 485 TR30 Transponder Windows PC DIGIVOTE III Software XGA USB The working range between the transponder and the v...

Page 13: ... as indicated by the insignias on the bottom of the battery container Operation with two Transponders TR30 Power supply VD30 parliamentary voting unit TK50 DVIII Charging and storage tray Video Projector VD30 parliamentary voting unit VD30 parliamentary voting unit VD30 parliamentary voting unit VD30 parliamentary voting unit VD30 parliamentary voting unit DIGIVOTE III Software XGA USB TR30 Transp...

Page 14: ...PWR PWR COM COM TR30 Transponder PWR COM max 9 TR30 This configuration allows a total distance about 1000 meters The inner transponders are connected by means of special adapters If required our planning department will assist you Usage of projectors To present the questions and results an adequate projector must be available for example an LCD projection panel for a well performed overhead projec...

Page 15: ...GIVOTE 1 Antenna swivel mounted 2 LED orange for status of rechargeable battery as option not relevant for single operation mode with USB connection 3 LED red for carrier detection 4 LED green for reception activity 5 LED yellow for transmission activity 6 tripod mounting screw 7 Safety eye obligation in many countries ...

Page 16: ...sed by mistake To switch off the transponder please press and hold the push button longer than 4 seconds For control LED CD RX and TX are off 9 Connection to Control PC via RS232 or RS485 XLR male 5 pin Connector for adapter cable in case of multi transponder mode 10 Connection to Control PC via USB XLR female 6 pin Connector for power supply in case of RS232 RS485 and multi transponder mode ...

Page 17: ...splay 4a Status indication of rechargeable battery 4b Status of transmission transmitting of voting confirmation of voting transmission 4c Radio contact to transponder 4d Status message e g to start voting 4e Displaying key input Yes No Abstain 5 ID Number of the voting unit 6 Charging status of rechargeable battery see manual TK50 DVIII 9 4 4a 4c 4e 4d 4b Start Voting Ja Yes1 1 depending on the l...

Page 18: ...33 MHz ISM band different RF channels selectable separate configuration channel Range The coverage is designed for up to 50 meter depending on environment conditions A room s geometry and RF propagation characteristics will influence actual range experienced Elevating the base station often results in a performance advantage Speed Over 200 keypads sec depending on voting mode and configuration Pow...

Page 19: ... delivery Software Digivote basic interactive Art Nr S4 1190 Software Digivote basic parliamentary Art Nr S4 1190 P Software Digivote interactive professional Art Nr S4 1111 NT TR30 Power Supply powers transponder when used with RS232 485 connector part no 19 0853 X6 TR30 USB 5 Connection Cable for USB connection part no 08 2410 5 TR30 232 10 Connection Cable for RS232 connection part no 08 2145 1...

Page 20: ...ction Transponder TR30 is not connected to the PC Distance to TR30 is too long Software configurations are not correct Check the connection to the PC Reduce the distance to the transponder See software manual Voting unit does not react by pressing any key Rechargeable batteries are discharged Insert the voting unit in the TK50 DVIII for charging minimum a few hours ...

Page 21: ...10 10 DIGI III VOTE Connection cable PC USB TR30 KSUSBA KKXLR6 BRÄHLER Konferenztechnik AG ICS PC USB A red grn TR30 shield 08 2400 5 5m 08 2400 10 10m Oehlbach USB cable DIGI III VOTE USB A plug Transponder cable 08 2410 5 5m 08 2410 10 10m KKXLR 6 22 1190 3 2 1 4 5 6 solder side Female connector wht blk wht grn red 1 3 2 4 5 6 ws gn rt GND blk sw nc Data Data nc UB OUTPUT Voltage 5V ...

Page 22: ...45 DIGI III VOTE Connection cable PC RS232 TR30 KKDSUB9 KSXLR5 BRÄHLER Konferenztechnik AG ICS PC RS232 female cable connector solder side view 22 9470 22 9490 gry brn wht TR30 male cable connector solder side view 22 1160 shield 13 6230 1 A5 1 DIGI III VOTE KSXLR 5 nickel DB9 plug 3 2 1 4 5 5 4 3 2 1 9 8 7 6 wht brn gry 08 2145 3 3m 08 2145 10 10m 08 2145 25 25m ...

Page 23: ...HLER ICS REV 1 00 Doku Netzteile 19 0853X6 cdr 060803 VO 19 0853 X6 wht 1 3 2 4 5 6 ws GND blk sw nc nc nc nc UB OUTPUT Voltage 5V KKXLR 6 22 1190 19 0853 3 2 1 4 5 6 solder side Female connector wht blk mains 100 240V also marked wire FRIWO 1812037 OUTPUT 5V 2 4A Mains adapter plugable depends on country ...

Page 24: ...nts due to faulty materials or manufacturing dependent on following procedure 1 The client declares that the fault is not due to empty discharged wrongly inserted or faulty batteries 2 Before sending the faulty product back to the company please obtain an RMA Return Material Authorisation number An RMA can be obtained by contacting us at the details below Phone 49 0 2244 930 100 or email sales bra...

Page 25: ..._______________________________________________ Phone __________________________________ Fax ________________________________________ Notes Comments ______________________________________________________________________________________ ______________________________________________________________________________________ _____________________________________________________________________________...

Page 26: ...VD30 parliamentary TR30 DIGIVOTE III 26 Copyright by Brähler ICS ...

Page 27: ...DIGIVOTE III VD30 parliamentary TR30 Copyright by Brähler ICS 27 Declaration of Conformity ...

Page 28: ...244 930 0 Fax 49 0 2244 930 450 http www braehler com Rental service Wahlfelder Mühle 3 D 53639 Königswinter Tel 49 0 2244 930 200 Fax 49 0 2244 930 430 E Mail rental braehler com Sales Auf der Alten Burg 6 D 53639 Königswinter Tel 49 0 2244 930 100 Fax 49 0 2244 930 450 E Mail sales braehler com For your nearest representative in 85 countries please contact our sales department Tel 49 0 2244 930 ...

Page 29: ......

Page 30: ...BRÄHLERICS Phone 02244 930 0 www braehler com BGE DIGIVOTEIII_parl doc Sep 09 04 0820 04 0850 ...