Page 1: ...tion Unit Operation and Maintenance Manual P N 900000136 REV B 1 Frequency Distribution Unit FDU 160i Operation and Maintenance Manual P N 900000136 REV B For Brandywine Communications products with t...

Page 2: ...tended to alert the user to the presence of un insulated dangerous voltage within the product s enclosure The dangerous voltage may be of sufficient magnitude to constitute a risk of electrical shock...

Page 3: ...FDU 160i FDU 160i Frequency Distribution Unit Operation and Maintenance Manual P N 900000136 REV B 3 Revision History Revision Date Initial Release 8 06 13 A 4 15 15 B 10 30 15...

Page 4: ...1 ACCESSING FUNCTIONS ON THE FDU 160I 8 4 1 1 VIEWING THE CURRENT STATUS OF THE FDU 160I SYSTEM 9 5 CHANGING THE SETTINGS ON THE FDU 160I 11 5 1 SELECTING A REFERENCE 11 5 1 1 CHANGING THE REFERENCE...

Page 5: ...nnel basis User control of the unit is via a built in Web Browser with user friendly graphical interface or via SNMP for system applications Applications for the FDU 160i include secure communications...

Page 6: ...Ethernet port J21 Connect the other end of the Ethernet cable to the network with an Ethernet hub or switch 2 1 4 Frequency Inputs Connect a frequency input sources to the frequency input connectors...

Page 7: ...he on position The system will display its power on cycle on the front panel The system will use LED lamps D7 through D17 to indicate each octet of the device s IP Address Network Mask and Gateway add...

Page 8: ...s bar of the web browser on a PC Smartphone or Tablet Figure 3 FDU 160i Web Page Interface Use the dropdown menu to select different functions of the FDU 160i to view the status of the system and to a...

Page 9: ...NU button select General from the status menu This shows information such as the current output time UTC time up time the current input reference the current output format current system state alarm s...

Page 10: ...rsal Time Coordinate UTC Up Time The length of time that the FDU 160i has been powered on Hour Meter This is the accumulated number of operating hours since the FDU 160i was first built Reference The...

Page 11: ...anual P N 900000136 REV B 11 5 Changing the Settings on the FDU 160i Figure 5 Reference Settings Page 5 1 Selecting a Reference From the menu select Reference from the settings submenu From the Select...

Page 12: ...or is out of threshold however once the primary source is restored the unit will immediately switch back Reversionary with Delay The system will automatically switch to the secondary source in the eve...

Page 13: ...Settings Figure 6 Output Settings From the main menu select Output from the settings submenu This lets the user change the Output levels of each individual frequency output The units dropdown selects...

Page 14: ...36 REV B 14 5 3 Changing the IP Address From the main menu select IP from the settings submenu From here the IP Address Subnet Mask and Gateway address of the unit can be selected In addition it is po...

Page 15: ...tings submenu From here the Read Community Write Community and Trap IP Address can be set Figure 9 SNMP Settings 5 4 1 Monitoring the FDU 160i using SNMP To monitor the FDU 160i via Simple Network Man...

Page 16: ...ntenance Manual P N 900000136 REV B 16 5 5 Changing The Location Setting From the main menu select Location from the settings submenu This setting tells the user where the unit is physically located w...

Page 17: ...select Password from the settings submenu From here the access password for the unit to prevent other users from changing settings can be set The current Username and Password are required in order t...

Page 18: ...160i by sending HELP command terminated by CR The FDU160i will display the HELP MENU as below FDU160i System Setup 925000120 1 01 05 Jul 9 2013 SN 36770 Hardware Ver A COMMAND Description HELP Show th...

Page 19: ...R Sets IP Mask and displays the above Help Menu IPGATEWAY SetGateway Address Set Get the Gateway Address decimal number Gateway4 Gateway 3 Gateway 2 Gateway 1 and Store into NVM Example IPGATEWAY CR N...

Page 20: ...PIC32 Boot loader Application program to upgrade main application through Ethernet Follow the below commands 1 Run the PIC32UBL exe 2 Check the Ethernet Enable checked box Make sure the IP Address 192...

Page 21: ...roducts come with a one year warranty If the unit is still exhibiting problems not covered by the above troubleshooting guide please contact us for technical support at support brandywinecomm com or c...