1.

Important Informa�on

2.

Included Parts

3.

Filter Head Assembly Instruc�ons

4.

Installa�on Instruc�ons

4.1. Auxiliary Tap Connec�on

5.

Plumbing in Your System

6.

Replacing the Filter Cartridge

7.

Warranty Informa�on

1. Important Informa�on

-

For correct opera�on of this appliance, it is essen�al to strictly observe these installa�on and opera�ng instruc�ons.

-

Do not use this product with water that is microbiologically unsafe or water of unknown quality without adequate disinfec�on before or
a�er this system.

-

Installa�on must comply with any exis�ng State or Local Plumbing codes. Some Plumbing Codes require the installa�on of water filter
systems to be carried out by a licensed plumber.

-

For COLD water use only. Maximum temperature 38°C. Minimum temperature 2°C.

-

For internal use only.

-

The inlet water pressure to this water filter housing must not exceed 900kPa (130psi).

-

A cer�fied pressure limi�ng valve not exceeding 650kPa (95psi), dual check backflow preven�on valve must be installed on the inlet line
immediately preceding this water filter housing. This valve is included with this system (see Item 10 in Parts Sec�on).

-

We also recommend the installa�on of a water hammer protec�on device to protect the water filter housing and its installa�on. Where
water hammer problems exist, a water hammer protec�on device must be installed. Symptoms of water hammer can be noisy, shuttering
and banging pipes when water consuming appliances are opera�ng or taps are turned off. Should the system not be used for 2 days or more,
flush 1-2 litres of water through the system before consuming the water.

-

To ensure the high level of performance and protec�on provided from this water filter system, only use Bombora replacement cartridges
which have a maximum cartridge life of 12 months.

-

A�er installa�on, check the output water with a test strip and then test every 6-8 weeks a�erwards to establish your filter life based on your
average use. The TH reading should be below low range (less than 80PPM). If you get a higher reading than this on installa�on, call us to
discuss adjus�ng your bypass setting or restric�ng water flow further. Suggested filter cartridge change is 12 months or when the so�ening
capacity is diminished (over 80 PPM TH), whichever comes sooner.

Summary of Contents for C150KIT-FINEST

Page 1: ...si dual check backflow preven on valve must be installed on the inlet line immediately preceding this water filter housing This valve is included with this system see Item 10 in Parts Sec on We also recommend the installa on of a water hammer protec on device to protect the water filter housing and its installa on Where water hammer problems exist a water hammer protec on device must be installed ...

Page 2: ...nlet and outlet sides of the Filter Head Assembly c with 3 4 revolu ons of tape 2 Attach the first 3 8 Female Fitting to 3 8 Quick Connect Fitting c i to inlet side of the Filter Head Assembly c with your hand un l ght and then complete the last half turn with a shi er NOTE Do not over ghten This may cause fittings to snap 3 Attach the second 3 8 Female Fitting to 3 8 Quick Connect Fitting c iii t...

Page 3: ...r flows through the filter corresponding with arrows on the head of the filter C Allow approximately 40mm clearance under the water filter cartridge for ease of removal 4 The first step of the installa on procedure is to obtain a water supply for the filter system Check the plumbing configura on under your sink select which of the following installa on methods is best suited to your plumbing insta...

Page 4: ... No tools or sealing materials are required It is important that tube is cut to length if required with straight square cuts and pushed firmly into fi ings to seal To install tubing immerse the end of the tubing in cold water to lubricate prior to pushing into the fitting 5 Measure a length of Poly Tube e to run from the bottom of the Faucet Connect Fitting h on the faucet to the outlet connec on ...

Page 5: ...he quick connect fitting and pull gently on the tubing to remove Make sure end of tube is cut square and not distorted Refit and test 7 Warranty Informa on The C150KIT FINEST Water Filter System is designed to operate at a maximum pressure of 900kPa 130psi and at a maximum temperature of 38 C Bombora Supplies warrants this system to be free from defects in material and workmanship for a period of ...