background image

USER INSTRUCTIONS 

PRE- PURCHASE INFORMATION

INSTALLATION INSTRUCTIONS

CHIMNEY HOOD

MODEL: K7088ASC - 

70,

90,100 &120CM

Summary of Contents for K7088ASC - 70

Page 1: ...USER INSTRUCTIONS PRE PURCHASE INFORMATION INSTALLATION INSTRUCTIONS CHIMNEY HOOD MODEL K7088ASC 70 90 100 120CM ...

Page 2: ... When installed between adjoining wall cabinets the wall cabinets must not overhang the hob hotplate The following applies when ducting out If the room where the cooker hood is to be used contains a fossil fuel burning appliance such as a gas or oil central heating boiler then its flue must be of the room sealed or balanced flue type This hood is not suitable for use in a room where any open flue ...

Page 3: ...internal house wiring and the terminations labelled LOAD are for connection for the appliance WARNING THIS APPLIANCE MUST BE EARTHED Important The wires in this mains lead are coloured in accordance with the following code Green Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminal...

Page 4: ...ves the best extraction performance Warning Any ducting used must be fire retardant Unpacking the hood On some models components are packed inside the polystyrene protection pieces Do not throw away the box and packaging until installation is fully completed Installation ATTENTION The appliance should be installed by a qualified electrician or competent person 1 Before fixing the hood install the ...

Page 5: ...rs generated by the cooking process When the sensor detects vapours etc the hood automatically switches itself on to the first speed Every 10 seconds the internal microprocessor monitors the data being received from the sensor and changes speed if necessary When the hood no longer detects vapours etc the hood continues to operate for a further few minutes to ensure all residual odours are eliminat...

Page 6: ...motor speed and is also used to turn the hood off Button D is also used to reset the Filter Alarm and start the countdown for the next 30 hours of operation After cleaning the grease filters simply press Button D whilst the central segment of display window C is illuminated or is flashing and this will reset the filter alarm E Button E is used to turn the hood on at the last speed set and to incre...

Page 7: ...6 1 2 3 4 5 6 7 8 ...

Page 8: ...stic use only 4 Any service work will generally entail removal of the telescopic flue assembly to access key components including the motor If the flue assembly has been boxed in by means of a bridging shelf or any type of furniture this must be removed prior to our engineer s visit Before calling for service please check the following 1 Is there a power failure Turn on the appliance to check the ...

Reviews: