WARNING  

 

CAUTION  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-

JURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If  you  have  questions,  contact  the  manufacturer  at  the  ad-

dress or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel  and  lock  the  service  disconnecting  means  to  prevent 

power from being switched on accidentally. When the service 

disconnecting  means  cannot  be  locked,  securely  fasten  a 

prominent warning device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by a qual-

ified  person(s)  in  accordance  with  all  applicable  codes  and 

standards, including fire-rated construction.

4.  Sufficient air is needed for proper combustion and exhaust-

ing of gases through the flue (chimney) of fuel burning equip-

ment  to  prevent  backdrafting.  Follow  the  heating  equipment 

manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), 

and  the American  Society  of  Heating,  Refrigeration  and Air 

Conditioning  Engineers  (ASHRAE),  and  the  local  code  au-

thorities.

5.  This product may have sharp edges. Be careful to avoid cuts 

and abrasions during installation and cleaning.

6.  When  cutting  or  drilling  into  wall  or  ceiling,  do  not  damage 

electrical wiring and other hidden utilities.

7.  Ducted fans must always be vented to the outdoors.
8.  Use only metal ductwork.
9.  Do not use this fan with any solid-state speed control device.
10. As an alternative, this product may be installed with the UL-

approved  cord  kit  designated  for  the  product,  following  in-

structions packed with the cord kit.

11. This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

1.  Never  leave  surface  units  unattended  at  high  settings. 

Boilovers cause smoking and greasy spillovers that may ig-

nite. Heat oils slowly on low or medium settings.

2.  Always  turn  hood  ON  when  cooking  at  high  heat  or  when 

cooking flaming foods (i.e. Crepes Suzette, Cherries Jubilee, 

Peppercorn Beef Flambé).

3.  Clean  ventilating  fans  frequently.  Grease  should  not  be  al-

lowed to accumulate on fan or filter.

4.  Use proper pan size. Always use cookware appropriate for the 

size of the surface element.

TO  REDUCE THE  RISK  OF  INJURY TO  PERSONS  IN THE 

EVENT  OF  A  RANGE TOP  GREASE  FIRE,  OBSERVE THE 

FOLLOWING:*

1.  SMOTHER FLAMES with a close-fitting lid, cookie sheet, or 

metal tray, then turn off the burner. BE CAREFUL TO PRE-

VENT  BURNS.  If  the  flames  do  not  go  out  immediately, 

EVACUATE AND CALL THE FIRE DEPARTMENT.

EVOLUTION

TM

 3

QP3 Series Range Hoods

READ AND SAVE THESE INSTRUCTIONS

  FOR DOMESTIC COOKING ONLY  

WARNING  

 

2.  NEVER PICK UP A FLAMING PAN — You may be burned or 

spread the fire.

3.  DO NOT USE WATER, including wet dishcloths or towels - 

violent steam explosion will result.

4.  Use an extinguisher ONLY if:

A.  You  know  you  have  a  Class ABC  extinguisher  and  you 

already know how to operate it.

B.  The fire is small and contained in the area where it started.
C.  The fire department is being called.
D.  You can fight the fire with your back to an exit.

* Based on “Kitchen Fire Safety Tips” published by NFPA.

1.  For indoor use only.
2.  For general ventilating use only. Do not use to exhaust haz-

ardous or explosive materials and vapors.

3.  To  avoid  motor  bearing  damage  and  noisy  and/or  unbal-

anced  impeller,  keep  drywall  spray,  construction  dust,  etc., 

off power unit.

4.  Do  not  use  over  cooking  equipment  greater  than  60,000 

BTU/hr. as the blower motor will shut down intermittantly.

5.  Your hood motor has a thermal overload which will automati-

cally shut off the motor if it becomes overheated. The motor 

will restart when it cools down. If the motor continues to shut 

off and restart, have the hood serviced.

6.  The top of the hood MUST NOT BE LESS than 24” and at a 

maximum of 30” above cooktop for best capture of cooking 

impurities.

7.  This hood is not intended to be used as a shelf.
8.  Please  read  specification  label  on  product  for  further  infor-

mation and requirements.

NOTE  If hood is to be installed non-ducted:
 

Purchase a set of (2) non-ducted filters for 30” wide 

hoods (Model BPPF30) & 36” wide hoods (Model 

BPPF36) or a set of (3) non-ducted filters for 42” wide 

hoods (Model BPPF42) from your local distributor or 

retailer and attach them to the aluminum mesh filters.

Installer: Leave this manual 

with the homeowner.

Homeowner: Cleaning, Maintenance and 

Operating instructions on page 2.

Summary of Contents for EVOLUTION 3 QP330BL

Page 1: ...lambé 3 Clean ventilating fans frequently Grease should not be al lowed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL ...

Page 2: ...een designed and tested to provide good capture of cooking impurities and odors under all normal cooking conditions regardless of the cooking location on the cooktop Please note that cooking on the rear burners will always result in the best capture of cooking impurities regardless of the hood design CLEANING MAINTENANCE For performance appearance and health reasons clean filter fan and grease lad...

Page 3: ...an be adjusted sequentially CLOCK SETTING Press the button once the hours will begin blinking in the LED screen Use the and buttons to set the appropriate hours for the clock A small indicator will illuminate in the left corner of the LED screen to designate pm After the hours are set press the button to advance the menu to the minute se lection The minutes will begin blinking in the LED screen Us...

Page 4: ...purchased at your local electronic supply store Use 8A 120V 5 mm diameter 20 mm long fast acting cartridge type fuses To replace a fuse 1 Disconnect power at service entrance 2 Remove filters and bottom pan 3 Remove and inspect fuse If it is not open blown additional diagnostics are needed MAIN FUSE RANGE HOOD CONTROL BOARD LIGHT FUSE REMOTE CONTROL The hood is compatible with Broan RF Remote Cont...

Page 5: ... 5 8 42 hood 17 5 8 42 hood 14 5 8 36 hood 14 5 8 36 hood 11 5 8 30 hood 11 5 8 30 hood 35 8 MAKE UP AIR DAMPER ELECTRICAL CONNECTION HOLE in wall ELECTRICAL ACCESS HOLE in cabinet bottom 21 8 67 8 107 8 25 8 HOOD MOUNTING SCREWS 5 45 8 8 DIA HOLE 7 IN ROUND DUCT ACCESS HOLE 7 IN ROUND DUCT ACCESS HOLE 11 17 5 8 42 hood 17 5 8 42 hood 14 5 8 36 hood 14 5 8 36 hood 11 5 8 30 hood 11 5 8 30 hood 7 I...

Page 6: ...INSTALLATION ONLY Attach 3 x 10 Damper Duct Connector if using 3 x 10 duct or 7 Round Duct Plate if using 7 inch round duct over the knockout opening Notes To accomodate off center ductwork the 3 x 10 damper duct connector can be installed up to on either side of the hood center and the 7 round duct plate can be installed up to on either side of the hood center Install the 3 x 10 Damper Duct Conne...

Reviews: