LP50100DC

LoProfile DC 

Ventilation Fan

 

INSTALLATION GUIDE 

READ AND SAVE THESE INSTRUCTIONS 

Installer: leave this guide with homeowner.

Easy installation

 

Table of Contents

Warnings and Cautions 

2

Typical Installation 

2

Installation

3-6

Operation

7

Cleaning and Maintenance 

7

Troubleshooting

7

© 2019 Broan-NuTone LLC

Summary of Contents for LoProfile LP50100DCF

Page 1: ...DE READ AND SAVE THESE INSTRUCTIONS Installer leave this guide with homeowner Easy installation Table of Contents Warnings and Cautions 2 Typical Installation 2 Installation 3 6 Operation 7 Cleaning and Maintenance 7 Troubleshooting 7 2019 Broan NuTone LLC ...

Page 2: ... to the outdoors 7 Acceptable for use over a tub or shower in the ceiling only when connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 8 This unit must be grounded Typical Installation CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 When installed in a wall or sloped ceiling the duct connector must point up 3...

Page 3: ... insulation stripper Wire cutter Materials needed 4 round metal ducting recommended for best performance Use of other ducting is acceptable but may impact performance Roof cap or wall cap built in damper recommended Tape to seal duct connections Drywall screws sheet metal screws or wire Electrical wiring and supplies per local code requirements 1 Remove from Packaging ...

Page 4: ...tallation 3 Install Ducting 2 Install in Wall or Ceiling UP Wall Ceiling OR 1 2 Insert tab into slot in housing 1 2 Tape 4 Ducting Wire 3 places Screw through housing on opposite side Tighten Screw into housing to secure mounting 1 2 3 2 1 4 É ...

Page 5: ...onnectors to secure wiring to the Knockout Plate Connect wires as shown in wiring diagram Attach cable clamp to Knockout Plate Knockout Plate may be oriented as desired Connect wires ON OFF SWITCH purchase separately KNOCKOUT PLATE RECEPTACLE 120 VAC LINE IN SWITCH BOX BLACK WHITE GROUND green or bare Do not use a speed control RED not used 3 2 1 4 ...

Page 6: ...duct REMOVE MASK BEFORE IN STALLIN G GRIL LE Utiliser ce couvercle pour empêcher la poussière de construction le plâtre ou la peinture d endommager l intérieur du pro duit ENLEVER LE COUVERCLE AVANT D INSTALLER LA GRIL LE Utilice esta cubierta para pre venir daños al interior del pro ducto debidos a polvo de construcción ro ciado en el panel de yeso o pintura RETIR E LA CUBIE RTA ANTES DE IN STALA...

Page 7: ...ssive or unusual noises replace the Blower Assembly Troubleshooting Symptom The fan does not run Check for an open fuse or circuit breaker in the building s service panel Check that the plug in connections for the Motor Control Motor and Speed Selection Switch are seated firmly in place Check that the Blower Wheel spins freely Symptom The fan runs erratically Check that the Blower Wheel is firmly ...