background image

MODELS

L100L • L150L • L200L • L250L • L300L

Page 1

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If

you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service panel

and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a qualified

person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting of

gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage elec-

trical wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be marked

as appropriate for the application and be connected to a GFCI
(Ground Fault Interrupter) - protected branch circuit.

9. Never place a switch where it can be reached from a tub or

shower.

10. This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

1. Never leave surface units unattended at high settings. Boilovers

cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.

2. Always turn hood ON when cooking at high heat or when cooking

flaming foods.

3. Clean ventilating fans frequently. Grease should not be allowed

to accumulate on fan or filter.

4. Use proper pan size. Always use cookware appropriate for the

size of the surface element.

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal

tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.

2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent

steam explosion will result.

4. Use an extinguisher ONLY if:

A. You know you have a Class ABC extinguisher and you al-

ready know how to operate it.

B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.

LOSONE SELECT

®

VENTILATORS

In-Line • 120V

READ AND SAVE THESE INSTRUCTIONS

TABLE OF CONTENTS

This manual is divided into sections as follows:

• “TYPICAL INSTALLATION”

This section shows a common installation in new and existing,
frame construction.
- Mounting (new construction)
- Mounting (existing construction)
- Wiring
- Ducting (straight through blower discharge)

• “MOUNTING OPTIONS”

• “WIRING OPTIONS”

- Wiring Plate Position

• “DUCTING OPTIONS”

- Blower Discharge Positions
- Ducting (right angle blower discharge)

• “USE AND CARE”

• “SERVICE PARTS”

• “WARRANTY”

Installer: Leave this manual with
the homeowner.

Homeowner: Use and Care
information on page 3.

CAUTION

1. For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2. To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off power
unit.

3.

If ventilator is installed in an unconditioned space (such as
an attic):

 Surround the ventilator with thermal insulation - to

minimize possible condensation.

4. Please read specification label on product for further informa-

tion and requirements.

Summary of Contents for LOSONE SELECT L100L

Page 1: ...s 2 Always turn hood ON when cooking at high heat or when cooking flaming foods 3 Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fi...

Page 2: ...ROUND DUCT FINISHED CEILING MATERIAL CEILING JOIST 16 centers shown 2 X 4 FRAMING wide side down MOUNTING BRACKETS Attached to opposite sides of housing upside down DUCTING Horizontal blower discharge Two ways to connect ductwork to a factory shipped unit Ventilator can be wired from outside of housing Use UL approved connectors to wire per local codes ROOF CAP ROUND ELBOW ROUND DUCT WALL CAP IMPO...

Page 3: ...top of housing HORIZONTAL POWER CABLE CONNECTION VERTICAL POWER CABLE CONNECTION Blower and duct connector in straight through dis charge position Factory shipped DUCT CONNECTOR DUCT CONNECTOR Blower and duct connector in right angle discharge position BLOWER BLOWER Change blower duct connector positions for right angle discharge DUCTING Right angle blower discharge Typical ductwork connection to ...

Page 4: ... FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse n...

Page 5: ...uedanincendiar 3 Limpieconfrecuencialosventiladores Nodebepermitirquelagrasaseacumule en el ventilador ni en el filtro 4 Utilice un sartén de tamaño adecuado Siempre utilice el utensilio adecuado al tamañodelelementodesuperficie PARA REDUCIR EL RIESGO DE LESION A PERSONAS RESULTADO DE UN INCENDIO DEBIDO A GRASA ACUMULADA EN LAS HORNILLAS PRO CURE LO SIGUIENTE 1 AHOGUE LAS LLAMAS con una tapa ajust...

Page 6: ...ONAL DE 1 3 8 cm MONTAJE Estructura existente Ventilador enviado de fábrica en posición de descarga derecho por del ventilador Unidad enviada de fábrica instalada en una estructura existente CONDUCTO REDONDO MATERIAL DE TERMINADO DEL CIELO RASO VIGUETA DEL TECHO se muestran centros de 16 40 6 cm ESTRUCTURA DE 2 X 4 5 08 x 10 2 cm con el lado del cableado hacia abajo ABRAZADERAS DE MONTAJE conectad...

Page 7: ...Cambie la posición del conector del ventilador y del conducto para una descarga derecho por del ventilador Conector del ventilador y del conducto en posición de descarga ángulo recto ajuste de fábrica VENTILADOR VENTILADOR Conexión típica de los conductos al ventilador cambiado a descarga ángulo recto TAPA DEL TECHO ADVERTENCIA Para reducir el riesgo de sufrir una descarga eléctrica antes de dar s...

Page 8: ...AY OTRAS GARANTIAS EXPLICITAS O IMPLICITAS INCLUYENDO PERO NO LIMITADAS A GARANTIAS IMPLICITAS DE COMERCIALIZACION O APTITUD PARA UN PROPOSITO PARTICULAR Durante este período de un año Broan NuTone reparará o cambiará a su opción y sin cobro cualquier producto o pieza que se encuentre defectuosa bajo uso y servicio normal ESTA GARANTIA NO SE EXTIENDE A ARRANCADORES DE LAMPARAS FLUORESCENTES Y TUBO...

Page 9: ...ent les ventilateurs d aération On ne doit tolérer aucune accumulation de graisse sur le ventilateur ou sur le filtre 4 Utiliser une casserole de grosseur appropriée Toujours utiliser une batterie de cuisineproportionnelleàl élémentdesurface AFIN DE DIMINUER LES RISQUES DE BLESSURES POUVANT SURVENIR LORSQU UN FEU SE DÉCLENCHE SUR LASURFACE DE CUISSON SUIVEZ CES DIRECTIVES 1 ÉTOUFFEZ LES FLAMMES av...

Page 10: ...S DE FIXATION Soufflerie préassemblée en position de décharge dans ligne Supports préassemblés pour plafonds de po 1 27 cm d épaisseur MONTAGE construction terminée CONDUIT CIRCULAIRE SOLIVE DE PLAFOND 16 po 40 6 cm centre CHARPENTE 2 x 4 côté large en bas SUPPORTS fixés aux autres côtés du boîtier et à l envers pour que le boîtier soit au ras du plafond fini CHARPENTE SUPPLÉMENTAIRE DE 1 po 3 81 ...

Page 11: ...ord de soufflerie et de conduit pour une décharge droit angle Raccordement de conduit typique à un ventilateur converti en décharge droit angle CHAPEAU DE TOIT AVERTISSEMENT Pour diminuer les risques de décharge électrique débrancher la source d alimentation avant toute opération d entretien Pour nettoyer la soufflerie Retirer la panneau de access débrancher la soufflerie du boîtier retirer les éc...

Page 12: ...ières ou la main d oeuvre pour une période d unanàcompterdeladated achatoriginal ILN YAPASD AUTRESGARANTIES EXPRIMÉESOUIMPLICITES INCLUANTMAISNONPASLIMITÉAUXGARANTIESIMPLICITES POURFINDECOMMERCIALISATIONETDECONVENANCEDANSUNBUTPARTICULIER Pendantcettepérioded unan Broan NuTone àsonchoix répareraouremplacera gratuitement toutproduitoupiècequis avèredéfectueuxsousutilisationetservicenormaux CETTEGARA...