background image

64000 SERIES

RESIDENTIAL USE ONLY

INSTALLER:  LEAVE THIS MANUAL WITH HOMEOWNER.

HOMEOWNER:  USE AND CARE INFORMATION ON PAGE 10

V03515 rev C

INSTALLATION INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

®

::

rangehoods

.

com

                               

Call 1-800-667-8721 anywhere in the US and Canada

  -

www.rangehoods.com

U      N      L      I      M      I      T      E      D

Broan at

::

rangehoods

.

com

  

is a division of 

kitchen

::

accessories

Summary of Contents for rangemaster 64000 series

Page 1: ...OMEOWNER USE AND CARE INFORMATION ON PAGE 10 V03515 rev C INSTALLATION INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS rangehoods com Call 1 800 667 8721 anywhere in the US and Canada www rangehoods com U N L I M I T E D Broan at rangehoods com is a division of kitchen accessories ...

Page 2: ...SE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS IF THE FLAMES DO NOT GO OUT IMMEDIATELY EVACUATEAND CALLTHE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels This could cause a violent steam explosion 4 Use an extinguisher ONLY ...

Page 3: ...ior blower Model 418 10 Rd adjustable elbow Adapter and damper supplied with hood Standard 3 1 4 x 10 duct Rough in kit supplied with P5 and P8 blowers Model P5 single blower 500 cfm 64000 SERIES HOOD 64000 SERIES RANGE HOOD SYSTEM Model 647 7 Rd wall cap Model 634 or 644 roof cap Model 643 8 Rd wall cap Flow deviator vertical exhaust only supplied with hood rangehoods com Call 1 800 667 8721 anyw...

Page 4: ...LLATION Dimensions for the most common installations are shown below We recommend you to install the hood at a minimum of 20 from an electric range and 24 from a gas range For optimal performance the hood should not be installed more than 30 from cooktop Hood Cabinets 30 maximum clearance Standard 36 h cook top Backsplash Hood Cabinets 20 minimum clearance 24 for gas Standard 36 h cook top Backspl...

Page 5: ... be installed before the hood shell because the hood shell covers the backsplash top mounting screws In order to be able to install the backsplash make sure you have at least 18 clearance between bottom of hood and range control panel or cooktop See instructions packed with backsplash 5 SELECT BLOWER OPTION EXTERIOR OR INTERIOR INTERIOR BLOWER Follow all subsequent steps of this manual EXTERIOR BL...

Page 6: ...w Note The deviator will not slide entirely into the hood you will notice 1 8 will remain 8 INSTALL THE ADAPTER Using 2 1 2 screws secure the adapter to the top or back of the hood Tape the adapter to the hood using duct tape to seal it rangehoods com Call 1 800 667 8721 anywhere in the US and Canada www rangehoods com U N L I M I T E D Broan at rangehoods com is a division of kitchen accessories ...

Page 7: ...ire clamp to secure the cable Place the hood under the cabinet and slide it in position Make sure the adapter damper assembly enters the ducting Secure the hood by tightening the screws completely 10 CONNECT WIRING Connect cable to wiring box using wire connectors Connect BLACK to BLACK WHITE to WHITE and GREEN under ground screw Reinstall wiring cover DO NOT FORGET TO CONNECT THE GROUND rangehood...

Page 8: ... the large part of the keyhole Slide the blower to its position screws in the small part of the keyhole Tighten the screws Reinstall impeller s and cover FOR DUAL BLOWER UNIT MAKE SURE THE IMPELLERS ARE CORRECTLY INSTALLED THE HOOD WILL NOT WORK CORRECTLY IF REVERSED Both impeller s are different in the dual blower one rotates clockwise and the other counterclockwise Each wheel and motor have an a...

Page 9: ...l the lights by rotating clockwise 14 INSTALL FILTERS It is recommended to install side filters first and finish with center one s 1 Insert upper end of filter into the hood tap end 2 Raise lower end toward the inside of hood 3 Position lower end of filter into channel and pull 4 While pulling the filter slide it under the inner retaining piece Baffle filters are available as an option see instruc...

Page 10: ...ach the hood During construction renovation cover the hood to make sure no dust sticks to stainless steel surface Avoid when choosing a detergent Any cleaners that contain bleach will attack stainless steel Any products containing chloride fluoride iodide bromide will deteriorate surfaces rapidly Any combustible products used for cleaning such as acetone alcohol ether benzol etc are highly explosi...

Page 11: ...if food warming shelves are not used CAUTION DO NOT PLACE HIGHLY FLAMMABLE MATERIAL ON WARMING SHELVES HEAT SENTRY Your hood is equipped with a Heat Sentry thermostat This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface 1 If blower is OFF it turns blower ON to HIGH speed 2 If blower is ON at a lower speed setting it turns the bl...

Page 12: ...o not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN S OBLIGATION TO REPAIR OR REPLACE AT BROAN S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow th...

Page 13: ...LINE BLACK HEAT LAMP 175W NEUTRAL WHITE HALOGEN LAMP 50W PAR20 HALOGEN LAMP 50W PAR20 HALOGEN LAMP 50W PAR20 GANG SPST ROCKER SWITCH SPST ROCKER SWITCH SPST ROCKER SWITCH SPST ROCKER SWITCH WITH NEON THERMAL CUTOFF 206 F ACT SMC1270PT SOLID STATE CONTROL MOTOR SOCKET FEM 2 POSITIONS TERMINAL BLOCK 8 POSITIONS SUPPLY PLUG MALE 3 POSITIONS HEAT LAMP 175W HEAT LAMP 175W NEUTRAL WHITE LINE BLACK range...

Page 14: ...FOR THERMAL CUTOFF RANGEMASTER SPEED CONTROLLER SPST CARLING SINGLE SWITCH SPST CARLING DOUBLE SWITCH SPST CARLING LIGHTED SINGLE SWITCH RANGEMASTER SPEED CONTROL BUTTON RANGEMASTER TERMINAL STRIP RANGEMASTER 10 POWER CORDS 10 RANGEMASTER CORDS FOR HEAT LAMP RANGEMASTER 10 CONTROL WIRE RANGEMASTER 10 LIGHTED SWITCH WIRE LOCK NUT 8 32 SCREW 8 32 X 1 2 QDRX MACHINE SCREW 8 32 X 1 4 LOCK NUT 6 32 SCR...

Page 15: ...R 165W CW BLOWER IMPELLER 7 094 x 3 375 CW CAPACITATOR 15 MFD MOTOR GROMMET G 431 1 MOTOR MOUNT WIRE LOOM IMPELLER RING WASHER 3 16 DI X 3 4 DE 8 TIE RAP METRIC SCREW M4 X 6MM PAN QDRX WIRE 18 TEW BROWN X 10 SCREW 8 X 3 8 T B 8 HEAD MACHINE SCREW 6 32 X 1 4 LOCK NUT 6 32 SCREW 10 32 X 3 8 T F GREEN 36 BLOWER POWER CORD STRAIN RELIEF FOR BLOWER POWER CORD POWER CORD 120 VOLTS STRAIN RELIEF FOR POWE...

Page 16: ...LOWER IMPELLER HOOD 7 094 X 3 375 CCW CAPACITOR 15 MFD MOTOR GROMMET G 431 1 MOTOR MOUNT WIRE COVER IMPELLER RING WASHER 3 16 DI X 3 4 DE 8 TIE RAP METRIC SCREW M4 X 6MM PAN QDRX WIRE 18 TEW BROWN X 10 SCREW 8 X 3 8 T B 8 HEAD MACHINE SCREW 6 32 X 1 4 LOCK NUT 6 32 SCREW 10 32 X 36 T F GREEN 36 BLOWER POWER CORD STRAIN RELIEF FOR BLOWER POWER CORD POWER CORD 120 VOLTS STRAIN RELIEF FOR POWER CORD ...