background image

 

Form No. PDS 361A.75.2

 

OIL-FIRED FURNACES

 

361AAN, 362AAN &

363AAP

 

Sizes 075 thru 210

 

 

361AAN

Upflow/Horizontal

362AAN

Low-Boy

363AAP

Upflow/Horizontal

(Large Capacity)

  

®

A

N

IN

D

EP

EN

DENT LABO

R

A

T

O

R

Y

T

E

S

T

IN

G

FOR PUBLIC

SA

F

E

T

Y

  

ama

  

Summary of Contents for 361AAN

Page 1: ... 75 2 OIL FIRED FURNACES 361AAN 362AAN 363AAP Sizes 075 thru 210 361AAN Upflow Horizontal 362AAN Low Boy 363AAP Upflow Horizontal Large Capacity A N I N D EPENDENT LABOR A T O R Y T E S T IN G FOR PUBLIC SA F E T Y ama ...

Page 2: ...The constant low speed blower switch provides air circulation during off cycles for indoor air filtration DURABLE CABINET The casing is constructed of prepainted steel for years of attractiveness Filter and filter rack are provided with each furnace SPECIFICATIONS Capacity and AFUE in accordance with U S Government DOE test procedures Permissible limits of the voltage range at which the unit will ...

Page 3: ...num 2 2 Horizontal Warm Air Duct Within 6 ft of Furnace 2 3 BOTTOM 0 0 FLUE PIPE Horizontally or Below Pipe 4 4 Vertically Above Pipe 8 8 FRONT 8 24 UNIT SIZE BLOWER MOTOR HP SPEED EXTERNAL STATIC PRESSURE IN WC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 036075 1 3 PSC High 1530 1475 1410 1340 1255 1170 1075 970 855 705 Medium 1240 1200 1150 1110 1065 1000 920 830 705 555 Low 870 850 830 805 765 720 ...

Page 4: ...d The constant low speed blower switch provides air circulation during off cycles for indoor air filtration DURABLE CABINET The casing is constructed of prepainted steel for years of attractiveness Filter provided with each furnace Capacity and AFUE in accordance with U S Government DOE test procedures Permissible limits of the voltage range at which the unit will operate satisfactorily Length sho...

Page 5: ...PIPE Horizontally or Below Pipe 4 Vertically Above Pipe 8 FRONT 8 UNIT SIZE BLOWER MOTOR HP SPEED EXTERNAL STATIC PRESSURE IN WC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 036105 1 3 PSC High 1795 1735 1675 1605 1550 1485 1425 1350 1275 1220 Medium 1365 1335 1305 1275 1255 1215 1155 1105 1050 985 Low 995 965 945 925 900 870 825 775 725 670 048125 1 2 PSC High 1905 1845 1770 1695 1630 1565 1490 1425 1...

Page 6: ...tion easy HEAVY DUTY BLOWER Blower motors are PSC type and 3 speed The direct drive blowers eliminate belt adjustments in the field The constant low speed blower switch provides air circulation during off cycles for indoor air filtration DURABLE CABINET The casing is constructed of prepainted steel for years of attractiveness Filter and frame are provided with each furnace Capacity and AFUE in acc...

Page 7: ...um and Warm Air Duct Within 6 ft of Furnace 1 1 BACK 2 2 TOP Furnace Casing or Plenum 2 2 Horizontal Warm Air Duct Within 6 ft of Furnace 2 3 BOTTOM 0 0 FLUE PIPE Horizontally or Below Pipe 9 9 Vertically Above Pipe 9 9 FRONT 24 24 UNIT SIZE BLOWER MOTOR HP SPEED EXTERNAL STATIC PRESSURE IN WC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 060210 3 4 PSC High 2485 2395 2305 2250 2145 2075 1975 1885 1780 ...

Page 8: ...ussed in this manual including Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product theory and skills programs is available using popular video based formats and materials All include video and or slides plus companion book Classroom Service Training plus hands on the products in our labs can mean increased confidence that really pays dividends in ...