BM22s, BM25s, 

BM25a

 & BM27s 

USER'S MANUAL 

 
1) PRODUCT DESCRIPTION 

Note: Top of the line model is used as representative for illustration 
purposes.  Please  refer  to  your  respective  model  for  function 
availability.

 

 

1) LCD display 
 
2) Rotary Selector to Select additional functions (

Models 27s & 22s 

only

), and to turn the Power On or Off (

Model 22s only

). 

Model 25s

 

& 25a 

does not have a physical Rotary Selector. 

 
3) Push-button to Select additional functions (all models), and to 
switch the Power On or Off (

Models 27s, 25s

 & 25a 

only

 
4) Input for all functions, or otherwise specified. Red test lead for 
positive (+) polarity and Black test lead for Ground reference (-) 
 

2) SAFETY 
Terms in this manual 

WARNING

  

identifies conditions and actions that could result in serious injury or even death to the user. 

CAUTION 

identifies conditions and actions that could cause damage or malfunction in the instrument. 

 
This  manual  contains  information  and  warnings  that  must  be  followed  for  operating  the  instrument  safely  and 
maintaining the instrument in a safe operating condition. If the instrument is used in a manner not specified by the 
manufacturer, the protection provided by the instrument may be impaired. The meter is intended only for indoor 
use. 

With  test  lead  tip  insulation  CAP,

  the  meter  is  protected,  against  the  users,  by  double  insulation  per 

IEC/UL/EN61010-1 Ed. 3.0

IEC/EN61010-2-030 Ed. 1.0

IEC/EN61010-2-033 Ed. 1.0, IEC/UL/EN61010-031 Ed. 

1.1 

and 

CAN/CSA-C22.2 No. 61010-1-12 Ed. 3.0

  to CAT III 300V & CAT II 600V (CAT II 450V for 

Model 25s

 & 

25a

). 

In case of removing test lead tip insulation CAP, to CAT II 600V (CAT II 450V for Model 25s

 & 25a

) only. 

 
Measurement  Category  III  (CAT  III)

  is  for  measurements  performed  in  the  building  installation.  Examples  are 

measurements on distribution boards, circuit-breakers, wiring, including cables, bus-bars, junction boxes, switches, 
socket-outlets in the fixed installation, and equipment for industrial use and some other equipment, for example, 
stationary motors with permanent connection to the fixed installation. 

Measurement  Category  II  (CAT  II)

  is  for  measurements  performed  on  circuits  directly  connected  to  the  low 

voltage installation. Examples are measurements on household appliances, portable tools and similar equipment. 
 

WARNING

  

To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. To avoid electrical shock 
hazard, observe the proper safety precautions when working with voltages above 60 VDC or 30 VAC rms. These 
voltage levels pose a potential shock hazard to the user. Do not touch test lead tips or the circuit being tested 
while power is applied to the circuit being measured. Keep your fingers behind the finger guards of the test leads 
during measurement.  Inspect  test  leads  and  probes  for  damaged  insulation  or  exposed  metal  before  using  the 
instrument. If any defects are found, replace them immediately.  

Summary of Contents for BM22s

Page 1: ... 1 Ed 3 0 IEC EN61010 2 030 Ed 1 0 IEC EN61010 2 033 Ed 1 0 IEC UL EN61010 031 Ed 1 1 and CAN CSA C22 2 No 61010 1 12 Ed 3 0 to CAT III 300V CAT II 600V CAT II 450V for Model 25s 25a In case of removing test lead tip insulation CAP to CAT II 600V CAT II 450V for Model 25s 25a only Measurement Category III CAT III is for measurements performed in the building installation Examples are measurements ...

Page 2: ...25s 25a is present the meter displays the appropriate voltage value in DC or AC whichever larger in peak magnitude Overload Alert Feature When above rated 600V 450V for Model 25s 25a is present the meter displays OL with a warning beep tone Disconnect the test leads from the signal immediately to avoid hazards Note Range Lock Feature When a measurement reading is being displayed in AutoCheckTM mod...

Page 3: ...s DCV is the default function Press SELECT button momentarily to select ACV The AC annunciator turns on Press momentarily again to activate the Line Level Hz function Note Line Level Hz input sensitivity varies automatically with ACV range selected when Line Level Hz is selected AC 6V range has the highest and AC 600V range has the lowest sensitivity Measuring the signal in ACV function WHILE sele...

Page 4: ...ily AGAIN selects Capacitance function Frequency function Model 22s only Rotate the rotary selector to the Hz position selects Frequency function Unlike the Line Level Hz Frequency function for Model 27s only as stated this Common Hz Frequency function is set only at the highest input sensitivity mainly for measuring small electronic signals of below 20VAC rms 4 3 OTHER FEATURES Power On Off For M...

Page 5: ...ect test leads from live circuits Loosen the screw from the case bottom Lift the end of the case bottom nearest the input test leads until it unsnaps from the case top Replace the battery Observe battery polarities with positive faces up towards the case bottom Replace the case bottom and ensure that the snap on the case top near the LCD side is engaged Re fasten the screw Note for Models 27s 25s ...

Page 6: ...del 22s Data Hold and 30ms MAX Hold Model 25a 25s 27s AutoCheckTM Automatic V Selection and EF Detection Accessories Battery installed and User s manual Optional Accessories BH 20R protective holster and BSC 20 soft carrying pouch Electrical Specification Accuracy is given as of reading digits number of digits or otherwise specified 23o C 5o C and less than 75 R H DC Voltage Models 25a 25s 27s RAN...

Page 7: ...nge accuracy is not specified 2 Accuracies with film capacitor or better 3 Updates 1 minute on large values 4 Specified with battery voltage above 2 8V half full battery Accuracy decreases gradually to 12 at low battery warning voltage of approx 2 4V Ohms Models 25a 25s 27s RANGE1 Accuracy 600 0 2 0 6d2 6 000k 1 2 6d2 60 00K 600 0K 1 0 4d 6 000M 2 0 4d Open Circuit Voltage 0 4VDC typical 1 AutoChe...

Page 8: ...s warranty does not apply to accessories fuses fusible resistors spark gaps batteries or any product which in BRYMEN s opinion has been misused altered neglected or damaged by accident or abnormal conditions of operation or handling To obtain warranty service contact your nearest BRYMEN authorized agent or send the product with proof of purchase and description of the difficulty postage and insura...