Installation Guide

Summary of Contents for Soundweb 9008

Page 1: ...Installation Guide ...

Page 2: ...etwork cables should be of type CAT 5 IMPORTANT SAFETY INFORMATION Do not remove covers No user serviceable parts inside refer servicing to qualified service personnel This equipment must be earthed It should not be necessary to remove any protective earth or signal cable shield connections to prevent ground loops Any such disconnections are outside the recommended practice of BSS Audio and will r...

Page 3: ... master for the network Off this unit is slaving to an external master clock Sync Steady indicates the presence of one or more valid network connections Flashing there is a problem with the incoming network signal check connections and or possibly the maximum cable length has been exceeded Activity Flashing Yellow indicates data transfer The flashing is not regular but dependent on the rate of tra...

Page 4: ...nd network cables and looms see the Product Overview 2000 catalogue from Direct Cable Systems Ltd Tel 020 7485 0899 www directcable co uk Neutricon Neutricon tour grade network cable P N 150001 Phoenix XLR audio cable P N 100521 Audio Output wiring convention Soundweb products provide cable shielding back from the destination to eliminate ground loop problems Therefore the shield S connection on a...

Page 5: ...he one without a connection to its Net Out socket to the first device the one without a connection on its Net In socket There must be no physical cable connection between the two end devices The connecting cable is CAT 5 network cable terminated with RJ45 connectors with all 8 cores wired straight through Note that the twisted pairs in any CAT 5 network cable must be wired to the following pin pai...

Page 6: ...nearly 3 wire mode This mode allows the use of linear pots or faders for continuous controls A pot would be wired as a potential divider with the top of the track connected to the reference output R the wiper to a control input and the bottom of the track to a common C For good performance pots with track resistance between 10K and 100KOhms are recommended LOGIC OUTPUTS Used to connect tally indic...

Page 7: ...ol Inputs and Logic Outputs connection diagram switch 2 wire mode relay LED relay 3600R 1800R 1200R unconnected ladder supply voltage 47kOhm log potentiometer 10K 100kOhm linear potentiometer switch 1k 1k 1k ladder 1k ground 4k7 3 wire mode 470R ...

Page 8: ...ted 108dB typical A weighted Maximum output level 20dBu Inter channel crosstalk 75dB Maximum network cable length 300m 1000ft Mains supply 85 270V AC 50 60Hz Power consumption 35VA Control Ports Control input voltage 0 to 4 5v Control input impedance 2 wire mode 4 7kOhms to 5V Control input impedance 3 wire mode 1MOhm Logic output voltage 0 or 5V unloaded Logic output impedance 440 Ohm Opto output...