background image

 
 

 

 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

WWW.OILSTOVES.CO.UK 

 

ROUND BUBBLE OIL STOVE © 

USER INSTRUCTIONS ISSUE 3 

12-07-06

 © 

Summary of Contents for Round Marine

Page 1: ...WWW OILSTOVES CO UK ROUND BUBBLE OIL STOVE USER INSTRUCTIONS ISSUE 3 12 07 06 ...

Page 2: ...minimal use of space allowing easy access past it 4 The stove can be supplied with a profiled drip tray 5 The top of the stove can be used for warming and cooking 7 Lightweight stainless steel or standard deck flanges and traditional chimney extensions can used providing a suitable antidowndraught terminal is fitted and providing that the required flue vacuum readings can be achieved 8 The dry sto...

Page 3: ... 10 3 The cross sectional area of the chimney diameter 10 4 The Flue gas temperature 10 5 The availability of replenishment air ventilation 10 6 The integrity of the chimney does it leak 11 The contents of the chimney are equal to a cylinder of hot air which depending upon its temperature and volume wants to move vertically with some force 12 Stopping it moving vertically are resistance such as 12...

Page 4: ...ve fuel for wintertime running 5 The tank should have conveniently sized filler and it must be vented 6 The tank should have 6 2 An isolation valve before an easily replaceable cartridge filter and another isolation device close to the appliance to allow for easy servicing 3 0 5 OIL LINE 1 The oil feed line starts after the fuel filter and proceeds to the point of entry where the oil line goes int...

Page 5: ...the baffle support plate 3 Catalyser body With the baffle plate removed it will be possible to lift out the catalyser complete with the flame ring 4 Circular Flame ring 5 Baffle support plate On dry stoves this plate can be removed for cleaning purposes by undoing the two M6 fasteners screwed in from the underside of the plate 6 The lighting port plug The lighting port plug pushes into the side of...

Page 6: ...nough air into the burner to allow correct blue flame combustion to occur 1 2 Check that the fuel is the correct type and quality 1 3 Check that the flow rates are correct 2 Where burners are incorrectly installed and are allowed to run at high fuel flow rates on low chimney vacuums long unsatisfactory yellow flame combustion and bad sooting will occur 2 1 To rectify this problem call your service...

Page 7: ...ety equipment associated with the stove oil supply and plumbing system Remove and clean out the oil supply pipe from the valve to the pot 7 As required 7a Replace the Mica viewing panel 7b Replace the descaling device packing gland It is recommended that one of each mentioned in 7a and 7b be carried as spares W WA AR RR RA AN NT TY Y The warranty covers all parts with exception of the components d...

Reviews: