6. Squeeze the O-rings to free them
from the grooves in the faucet spool.
NOTE - Wash all parts, the air filter,
and the hoppers by hand! The use
of automatic dishwasher chemicals
may damage the plastic. Do not
immerse the hopper lid
assemblies. Rinse thoroughly
before lubrication & assembly.
DISASSEMBLY & CLEANING
Empty all product from the hoppers before proceeding!
2. Pull the auger from the cooling
drum.
3. Disassemble the auger for
cleaning by spreading apart the
latches and removing each piece.
4. Spread the sides of the dispense
handle and pull it off to remove the
faucet pieces.
5. Push the metal pin out through the
faucet. Unscrew the plastic cap, and
push the faucet spool and spring out
the bottom.
LUBRICATION & ASSEMBLY
Lubricate after cleaning & before reassembly.
(Refer to product literature for Bunn approved lubricant.)
1. Squeeze some lubricant into hand.
6. Install the seal on the auger shaft.
7. Roll the O-rings off of the faucet
spool.
8. Remove the black plug from the
faucet spool for cleaning. Do not use
tools to remove this.
2. Apply a thin film of lubricant to the
cooling drum seal.
3. Install the seal over the flange at
the rear of the cooling drum as
shown.
4. Press the seal firmly into place.
12. Slide the O-rings onto the spool.
7. Align the auger shaft with the flat
fin of the auger. Push the auger as
far as it will go and rotate it so the
flat fin is pointing up.
8. Install the hopper over the cooling
drum with auger. Slide it into place
and push it down as far as it will go.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Whether liquid concentrate or granulated powder, all product must be
thoroughly mixed BEFORE adding it to the hoppers.
OPERATIONS
All switch rockers towards the center of the drawer is the typical operating
position for an ice product in each hopper.
At night, simply place the DAY/NIGHT switch in the night position
AUGER ASSEMBLY
(For early augers only.)
There are six pieces that snap together to make up the auger assembly.
They should be taken apart for cleaning and then reassembled for use.
BE CAREFUL, DON’T GET PINCHED!
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
1. Snap one of the auger sections to
the long auger latch.
2. Snap another auger section in
place.
3. Snap the third auger section in
place.
4. Snap the auger nose onto the last
section installed.
5. With the long auger latch on top,
place the short auger latch inside the
augers and snap it onto the
assembly.
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
1. Lift the hopper up
slightly, then use a hard
plastic utensil to pry it up. Pull
forward to remove.
5. Apply a thin film of lubricant to
the inside of the auger shaft seal.
9. Set the lid on the hopper. Slides
front-to-back or lifts off for filling.
11. Apply a thin film of lubricant to
the faucet spool O-rings.
13. Reinstall
the plastic cap,
spring, spool, and metal pin. Spread
the dispense handle and reinstall it.
14. Plug-in the hopper lid lamp
cable.
9. Pull down, then out on the air filter
at the rear of the dispenser.
10. Reinstall the black plug into the
faucet spool. Do not lubricate the
plug.
15. Assemble the drip tray.