background image

BURG-WÄCHTER UK

Eurocam Technology Park
Chase Way, Bradford BD5 8HW

burg.biz/uk

Electronic c

ombination

with finger

scan

Summary of Contents for SecuTronic TRSE 12H

Page 1: ...BURG WÄCHTER UK Eurocam Technology Park Chase Way Bradford BD5 8HW burg biz uk Electronic combination with fingerscan ...

Page 2: ...display shows when this is possible see section 3 Fingerprint sensor Fingerprints can be stored via the fingerprint sensor or used to open the safe 1 Design en SecuTronic Operating instructions Dear customer Thank you for choosing a BURG WÄCHTER safe with an electronic SecuTronic locking system These locks are certified according to ECB S Class B You have purchased a product that meets extremely h...

Page 3: ...o open the safe during this time even with a valid user or administrator code BURG WÄCHTER UK 2 A valid pin code must also be entered to open the door with a fingerprint Background All fingerprints do not receive full validity in the current software version Full validity must be achieved in order to obtain an opening authorisation Consequently a valid pin code of another user is also required Whe...

Page 4: ...actory set code and the user code must be carried out with the safe door open After the locking system has been changed to a new code it must be tried several times with the door is open to ensure it works BURG WÄCHTER UK Input options Number keys The numbers 1 0 are used for input e g when entering the code Func key The Func key adapts its function to the situation You change to the previous menu...

Page 5: ...etting 1 2 3 4 5 6 Please turn the knob appears in the display Turn the knob and open the door 4 Code entry FUNC M Please turn the knob Code change Language Sprache Administrator Info FUNC 1 2 M A I N M E N U Code entry FUNC M Opening with fingerprint Switch on the lock using the key Move a programmed finger from the top to bottom centrally over the sensor The message Validity not achieved appears...

Page 6: ...ser Create Create code Create fingerprint Assign Assign code Assign fingerprint Delete Time functions Set time Set date Automatic ST WT Delay time Programming Database update Firmware update Reorganise Processes Display Save Setup Register FP reset Generate AES key Info System info System check ...

Page 7: ...t code Switch on the lock using the key Then press Main menu appears Confirm with You can use the keys 1 or 2 to scroll until the administrator user is selected for which you wish to change the code for Confirm with Enter the old or factory code that was previ ously set using the keyboard and press Enter the new code using the keyboard and confirm with Repeat your entry and confirm it again with C...

Page 8: ...h User appears Confirm with Enter the administrator code to acquire the authorisation for programming The next free memory cell is displayed e g USER 0002 CD Enter the 6 digit code and confirm it with Use key 1 or 2 to scroll through the possible combinations If you have not selected a combination confirm 3x with If you have selected the combination FP you will create your fingerprint as described...

Page 9: ... Create Code Create Finger 1 FUNC U S E R Menu Administrator User Create continued Sub menu Administrator User Assign Create code Switch on the lock using the key Then press The main menu appears Scroll with the 1 or 2 key until the Administrator menu item is highlighted Confirm with Administrator appears Confirm with User appears Scroll with the 1 or 2 key until the Assign menu item is highlighte...

Page 10: ...gerprint menu item is highlighted Confirm with Enter the administrator code to acquire the authorisation for programming Assign appears You can use the keys 1 or 2 to scroll until the user is marked whose fingerprint is supposed to be assigned Confirm with Create fingerprint appears Move the finger from the top to bottom centrally and a number of times over the sensor The display will either promp...

Page 11: ...for programming You can use the keys 1 or 2 to scroll until the user is marked whose code is supposed to be deleted Confirm with Dataset has been deleted appears Press any key Menu Administrator Restructure Switch on the lock using the key Then press Main menu appears Scroll with the 1 or 2 key until the Administrator menu item is highlighted Confirm with Administrator appears Scroll with the 1 or...

Page 12: ...2 key until the menu item Administrator is highlighted Confirm with Main menu Administrator appears Scroll with the 1 or 2 key until the menu item Time functions is highlighted Confirm with Administrator Time functions appears Confirm with Enter the administrator code to acquire the authorisation for programming The time 24 hour rhythm can be set via the keyboard Confirm with Data has been saved a...

Page 13: ...any key Automatic changeover between Central European Summer Winter Time Switch on the lock using the key Then press The Main menu appears Scroll with the 1 or 2 key until the menu item Administrator is highlighted Confirm with Administrator appears Scroll with the 1 or 2 key until the menu item Time functions is highlighted Confirm with Time functions appears Scroll with the 1 or 2 key until the ...

Page 14: ...tions appears Scroll with the 1 or 2 key until the menu item Delay time is highlighted Confirm with Enter the administrator code to acquire the authorisation for programming Where a delay time has already been set it must first be run through The delay time 0 99 minutes can be set via the keyboard Confirm with Data has been saved appears Press any key Menu Administrator Programming Menu Administra...

Page 15: ...r In the event of a complete system failure the electronic control panel may have to be registered again with the locking mechanism Switch on the lock using the key Then press Main menu appears Scroll with the 1 or 2 key until the Administrator menu item is highlighted Confirm with Administrator appears Scroll with the 1 or 2 key until the Register menu item is highlighted Confirm with Enter the a...

Page 16: ...sing Enter appears Confirm with Thereafter there is no need to do anything further in the process The message Do not interrupt power appears The message on the display disappears for some time When the update is complete the message Firmware update completed appears Switch on the lock using the key The press The Main menu appears Scroll with the 1 or 2 key until the menu item Administrator is high...

Page 17: ...esses Save Please insert a FAT 32 formatted microSD card into the microSD card slot Switch on the lock using the key The press The Main menu appears Scroll with the 1 or 2 key until the menu item Administrator is highlighted Confirm with Administrator appears Scroll with the 1 or 2 key until the menu item Processes is highlighted Confirm with Processes appears Scroll with the 1 or 2 key until the ...

Page 18: ...in the Code Change menu In the event of a complete system failure the electronic control panel may have to be registered again with the locking mechanism Switch on the lock using the key The press The Main menu appears Scroll with the 1 or 2 key until the menu item Administrator is highlighted Confirm with Administrator appears Scroll with the 1 or 2 key until the menu item Setup is highlighted Co...

Page 19: ...e the key to return In this menu you can have several pieces of infor mation of the system displayed Menu info System info Switch on the lock using the key The press The Main menu appears Scroll with the 1 or 2 key until the menu item Info is highlighted Confirm with Info appears Confirm with Enter the administrator code to acquire the authorisation for programming The system information is displa...

Page 20: ...er across the sensor so that more area of your fingerprint can be read Position in the mid dle and repeat Position your finger in the middle of the sensor Incorrect code Enter a valid code No access An unsaved fingerprint has been used Repeat with a fingerprint that has already been created Error messages Technical details Number of administrator codes 1 Number of user codes 9 max Number of finger...

Page 21: ...ectronics This will require a Torx T8 screwdriver BURG WÄCHTER UK Let the lid slide out together with the batteries Remove the old batteries and dispose of them according to the disposal instructions Replace the batteries with four new 1 5 V AA Mignon batteries and according to the correct polarity For this purpose illustrations are shown on the battery holder Please use branded batteries and no r...

Page 22: ...ted to your dealer together with the original documentation For returns all undamaged device parts must furthermore be in the factory setting due to your right of revocation Failure to comply with this will invalidate the warranty 21 Disposal of the device Dear customer Please help us avoid unnecessary waste Should you intend to dispose of this device at any time please remember that many componen...

Page 23: ...Notes BURG WÄCHTER UK 22 ...

Page 24: ...BURG WÄCHTER UK Eurocam Technology Park Chase Way Bradford BD5 8HW Tel 44 0 1274 395 333 E mail ukcs burg biz burg biz uk ...

Reviews: