BVL Power Pack 

Service & Specification Manual 

 

Manufactured by BVL Controls Ltd 

Summary of Contents for BVL-056

Page 1: ...BVL Power Pack Service Specification Manual Manufactured by BVL Controls Ltd...

Page 2: ...HP R 404a 208 230 VAC WATER COOLED CWW 2 1 2 HP R 404a 120 VAC CWW 34 3 4 HP R 404a 208 230 VAC DESCRIPTION COOLING DISTANCE from cooler to faucet ECO 025 UP TO 25 of cooling line or ice tower ECO 03...

Page 3: ...83 A BTU 3120 4610 5800 5420 6700 Refrigerant R 134a R 404a R 404a R 134a R 404a Charge 18 oz 19 oz 18 oz 16 oz 21 oz Tank Capacity 12 gal 12 gal 12 gal 12 gal 12 gal Foam insulation 1 1 1 1 1 Weight...

Page 4: ...13 oz 12 oz 15 oz 10 oz 10 oz Tank Capacity 3 gal 3 gal 8 gal 3 gal 8 gal Foam insulation 0 5 1 0 5 0 5 0 5 Weight 60 lb 65 lb 95lb 97 lb 92 lb Pressure approximate 18 low 150 high 18 low 150 high 18...

Page 5: ...404a R 404a R 404a Charge see label on unit 5 lb 5 lb 5 lb 6 lb 6 lb 6 lb Tank Capacity 28 gal 28 gal 28 gal 28 gal 28 gal 28 gal Foam insulation 1 1 1 1 1 1 Weight 257 lb 277 lb 297 lb 275 lb 295 lb...

Page 6: ...Triple Motor Bath Option Used With CWA or CWW Top view for CWA 3 CWA 2 CWA 34 and also CWW units 2 PUMPS 3 PUMPS Triple Quadruple Motor Bath Option Used With CWA 100 and 175 Top view for CWA 100 and...

Page 7: ...account and will be credited upon receipt of the defective part In Canada BVL Controls Ltd 661 de la Sabliere Bois des Filion Quebec Canada J6Z 4T2 Phone 1 866 BVL CONTROLS 285 2668 Direct Line 450 9...

Page 8: ...the pump before filling the tank The pump must always run to have a constant agitation in the tank and avoid damaging the compressor 6 Replace the cover on top of the tank 7 Before plugging the power...

Page 9: ...2 gallons 2 x 4 liters for the CMV 030 and add water until just below the overflow 6 Before plugging the pump ensure that the installation and connections have been made to required specification Aft...

Page 10: ...always use the lifting handles to raise the unit and pour 3 gallons 3 X 4 liters of glycol 100 in the tank and add water until just below the overflow 6 Before plugging the pump s ensure that the ins...

Page 11: ...dles to raise the unit and pour 3 gallons 3 X 4 liters of glycol 100 in the tank and add water until just below the overflow 6 Before plugging the pump s ensure that the installation and connections h...

Page 12: ...ircuit Repeat step 3 and 4 for each pump 5 Remove the unit from the top of the tank always use the lifting handles to raise the unit and pour 3 gallons 3 X 4 liters of glycol 100 in the tank and add w...

Page 13: ...d pump in a closed circuit and always run it 24 hours a day to have a constant agitation in the tank and avoid damaging the compressor 5 Remove the unit from the top of the tank always use the lifting...

Page 14: ...every year except in very hot areas where it should be changed every six 6 months 1 Check liquid monthly a If level is low fill with water b If ice builds up remove one gallon of water and replace wit...

Page 15: ...cooler B Check applied pressure to barrel C Check equipment D Warm product lines A Adjust cooler temperature between 34 and 36 F B Adjust setting on regulator for proper pressure C Check the physical...

Page 16: ...n reservoir for liquid flow Replace pump B Replace motor C Refer to 2 D Remove from any hot water pipes or kitchen area with stove or glass washer E Remove lines from PVC thoroughly dry PVC and repair...