HVLP AIR CAP AND FLUID NOZZLE CHART
MODEL
NO.
AIR CAPS
Press /
Siphon
*MAX GUN
INLET PRESS.
FOR HVLP
FAN
CONTROL
SCFM @
MAX GUN
INLET
AIR CAP
RING
AVAILABLE FLUID
NOZZLES TIPS
NEEDLES /
marking on needle
23-1008
pressure
40**
13.5
33-0208 0.8mm (.022")
40-1308 (308)
23-1010
pressure
40**
13.5
33-0210 1.0mm (.040")
40-1310 (310)
23-1012
pressure
40**
13.5
33-0212 1.2mm (.046")
40-1312 (312)
23-1013
pressure
40**
13.5
33-0213 1.3mm (.052")
40-1313 (313)
23-1014
pressure
40**
13.5
33-0214 1.4mm (.055")
40-1314 (314)
23-1015
pressure
40**
13.5
33-0215 1.5mm (.059")
40-1315 (315)
23-1017
pressure
40**
13.5
33-0217 1.7mm (.070")
40-1317 (317)
23-1019
pressure
40**
13.5
33-0219 1.9mm (.075")
40-1319 (319)
23-1022
pressure
40**
13.5
33-0222 2.2mm (.086")
40-1322 (322)
Actual fluid nozzle and air cap combinations are determined by application (see application chart page 4)
*Note: Air cap test gages are available to confirm HVLP compliance.
*Gun inlet pressures may vary as required by application
**When using optional gun regulator, inlet pressure changes to 45psi
Included
L300H
60-1502 (#2)
L
L
L
L
Lynx 300H
ynx 300H
ynx 300H
ynx 300H
ynx 300H
PRESSURE FEED SPRAY GUN
PRODUCT INFORMATION
Coating Atomization Technologies 337 South Arthur Avenue, Louisville CO 80027 Phone: 888.820.4498, Fax: 303.438.5708