background image

   

 

PIR Sensor 

Detects movement within the unit’s detection range, 
allowing load control in response to changes in occupancy. 

IR Receiver 

Receives control and programming commands from an  
IR (infrared) handset. 

Light Level Sensor 

Measures the overall light level in the detection area  

Status LED 

The LED flashes 

R

ed to indicate the following:

 

Walk Test LED active 

        

when movement is detected

 

Valid setting received 

 

 

PIR lens 

which covers... 

 

IR Receiver 

Light Level Sensor 

Status LED 

Overview 

The EBMINT series of miniature PIR (passive infrared) 
presence detectors provide automatic control of lighting 
loads with optional manual control using an infrared 
handset. It is specifically designed for mounting onto a 
lamp or louvre (using the louvre fitting bracket). 
Three models are available: premium, direct dim, and 
analogue dim all of which will switch incandescent, 
fluorescent, compact fluorescent and LED lighting. The 
direct dim variant controls DALI or DSI digital dimming 
ballasts whilst the analogue dim variant controls 1-10V 
dimming ballasts. 
The unit detects movement using a PIR sensor and turns 
the load on. When an area is no longer occupied the load 
will switch off after an adjustable time out period. 
All models come pre-wired with a 1m silicon cable. 
All functionality is fully programmable using an IR handset. 

Features 

Integrated PIR detectors 

EBMINT 

Product Guide 

Cable to luminaire control gear 

Fixing for louvre fitting bracket 

Summary of Contents for EBMINT

Page 1: ...al control using an infrared handset It is specifically designed for mounting onto a lamp or louvre using the louvre fitting bracket Three models are available premium direct dim and analogue dim all...

Page 2: ...ection diagram Range Walk towards Walk across Height Range Diameter 7m 10m 2 8m 5m Height Range Diameter 7m 16m 2 8m 9m Note illustration shows an average of the walk across and walk towards figures b...

Page 3: ...er s datasheet for details As the EBMINT DD AD are able to dim the lamps using DALI DSI or 1 10V the products provide a facility to disable this for a given period of time Operation By setting the Bur...

Page 4: ...ube The cable must not touch the any part of the lamp 1 2 3 4 1 2 3 4 1 2 Louvre fitting Compact reflector fitting 1 2 3 4 Select correct clip for lamp T5 or T8 Panel mounting using lugs Use the lugs...

Page 5: ...knockout or between gear tray and housing of luminaire Connect the Neutral Disconnect the Live to the ballast Using the supplied terminal block connect the Live switched output Black from detector to...

Page 6: ...ive supply to the circuit is good Check that the load is functioning by bypassing the sensor e g link L and L Out HINT The Walk Test LED function can be used to check that the unit is detecting moveme...

Page 7: ...g Note the Lux Off Level value must always be greater than the Lux On Level value Load Type DD only DALI 2 DALI 7 DSI 2 DALI on Sets the ballast control protocol to be used by the output channel Sensi...

Page 8: ...e On Delay to allows the first channel to switch on after the second channel A typical application for this would be where a detector is controlling lighting and air conditioning in an area When the o...

Page 9: ...then it is 10 Max Value 100 0 to 100 Maximum dimming output level Min Value 0 0 to 100 Minimum dimming output level Memorise N Yes or No If this is set to Yes the last manual lux level set will be me...

Page 10: ...AD On 344mW Off 268mW Cable specification 1m silicon insulation and sheath PRM 3 x 0 75mm2 AD DD 3 x 0 75mm2 2 x 0 50mm2 Temperature 10 C to 50 C Humidity 5 to 95 non condensing Material Flame retarda...

Reviews: