DIGITAL MULTIMETER
OPERATION MANUAL
CONTENTS
T8229
5 in 1 DMM
CABAC
8 Distribution Place,
Seven Hills, NSW, 2147.
www.cabac.com.au
Page 1: ...DIGITAL MULTIMETER OPERATION MANUAL DIGITAL MULTIMETER CONTENTS T8229 5 in 1 DMM CABAC 8 Distribution Place Seven Hills NSW 2147 www cabac com au...
Page 2: ...any damages have been incurred 1 1 4 Test leads must be kept in good condition Check whether the insulation on test leads has been damaged and any wire has been exposed 1 1 5 Use the test leads suppl...
Page 3: ...sy Overload protection and low battery indication are provided It is an ideal multi function instrument with scores of practical applications for professional workshop school hobby and home use he met...
Page 4: ...istance frequency duty capacitance diode and continuity COM Input Jack common input connection for current voltage resistance frequency duty capacitance diode continuity temperature measurement 9 DIGI...
Page 5: ...4V 1mV 40V 10mV 400V 100mV 1000V 1V 0 7 of reading 2 digits Input Impedance 10M Overload protection 400mV range 250V DC or rms AC 4V 1000V ranges 1000V DC or 750V rms AC Max input voltage 1000V DC or...
Page 6: ...z 10 z 199 9kHz z 100 z 2 0 of reading 5 digits 200kHz for reference only b Hz range Measurement range 0 200kHz Input voltage range 0 5V 10V rms AC higher input voltage at higher frequency Overload pr...
Page 7: ...ux 10Lux 40000 10Lux 5 0 of reading 10 digits at color temp 2856K calibrated to standard incandescent lamp Re eatability 2 3 2 13 Diode Test Range e esolution Function 1mV displaying approximate forwa...
Page 8: ...TRUCTION 3 The meter will enter the manual range mode after the REL button is pressed REL mode is not available for Hz Duty range because it is an automatic range 4 Press the REL button again to cance...
Page 9: ...ds contact the circuit the true reading will be shown 29 DIGITAL MULTIMETER OPERATING INSTRUCTION 2 nder the manual range mode when only OL or OL is shown on the LCD it means the measurement has excee...
Page 10: ...the COM jack When the current to be measured is under 400mA plug the red test lead into the mA jack when the current to be measured is over 400mA but under 10A plug the red 33 DIGITAL MULTIMETER OPERA...
Page 11: ...ATING INSTRUCTION 4 19 6 Read the resistance on the main indicator of the LCD NOTE If the test leads are open or the resistance of the circuit is over 400 OL will appear on the LCD 4 20 MEASURING RELA...
Page 12: ...A windscreen should be placed in front of the microphone in such circumstances 4 24 MEASURING LUMINANCE WARNING To avoid damage to the meter do not connect the input plug to any electric signal 4 24 1...
Page 13: ...ies with new ones 5 1 4 Put the battery cover back and fix it again to its origin form NOTE Do not reverse the poles of the batteries 5 2 REPLACING FUSE 5 2 1 Fuses rarely need replacement Almost all...
Page 14: ...6 ACCESSORIES 1 Test leads electric rating 1000V 10A 1 pair set 2 Thermocouple K type TP01 1 set 3 Operation Manual 1 copy 48 Ordering Information Part No T8229...