background image

Customer Care Australia P: 133 122 F: 1300 303 310 E: sales@cabac.com.au W: cabac.com.au 

A: 8 Distribution Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 8 0077 6969 F: 8 0088 6969 E: sales@cabac.co.nz W: cabac.co.nz

1

 

Version 1 

CABAC UNINTERRUPTIBLE POWER 

SUPPLY 

   

   

   

USER’S MANUAL 

UPS600DV3   

UPS1000DV3   
UPS1500DV3   

Summary of Contents for UPS1000DV3

Page 1: ...ales cabac com au W cabac com au A 8 Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 1 Version 1 CABAC UNINTERRUPTIBLE POWER SUPPLY USER S MANUAL UPS600DV3 UPS1000DV3 UPS1500DV3 ...

Page 2: ... co nz W cabac co nz 2 2 of 21 Contents General Safety Instructions 3 Conditions of Use 3 Electrical Safety 4 Safe Operating Practices 5 Battery Information 7 Introduction 8 Performance 8 Installation Instructions 10 Physical Appearance 11 Front Panel Operational Indicators 12 Operation 13 Specification 14 Maintenance 15 Software Installation 16 Load configure reference 20 Troubleshooting 21 ...

Page 3: ...ain hazardous voltages internally that may cause electric shock There are no user serviceable parts inside For service please contact your nominated service agent Conditions of Use This equipment is designed for domestic use only The manufacturer neither recommends nor knowingly sells this product for use in critical life support applications 1 Intended for installation in a controlled environment...

Page 4: ...e UPS cover It may contain hazardous voltages internally that may cause electric shock There are no user serviceable parts inside For service please contact your nominated service agent 1 The Cabac UPS will provide a 220 240VAC 1φ single phase rate power source Please verify that this model matches your AC mains load voltage requirements 2 The Cabac UPS must be earthed at all times during operatio...

Page 5: ...unication port are kept separated by at least 25 mm from the power cords to and from the UPS input and output Safe Operating Practices This pluggable type A equipment has factory installed batteries and hence may be operated by anyone that has read and understood this manual During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the conne...

Page 6: ...d P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 6 6 of 21 disconnected 5 Turn off and unplug your UPS from the outlet and contact your nominated service agent if o The power cord or plug damaged o Liquid has been spilled on the UPS o The fuse blows frequently o The UPS does not operate even when user follows the operating instructions ...

Page 7: ...to the skin and eyes 3 A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles 4 NOTE The batteries used in your Cabac UPS are maintenance free This means that you DO NOT need to check the battery fluid levels Trying to do so may c...

Page 8: ...er is used as the main controller that renders the product an intelligent UPS capable of self protection and fault diagnosis A built in AVR function automatically adjusts itself to maintain a power supply of stable voltage when the utility power is of high or low voltage High performance surge suppression protects your computer from electrical noise and damaging power surges Performance Your Cabac...

Page 9: ...ection When the UPS is turned ON it immediately performs an inspection of the battery capacity Automatic Voltage Regulation Corrects over and under voltages without draining the battery This preserves battery resources and ensures your UPS will provide the optimum runtime and optimum voltage source during a power blackout Surge Protection Protects hardware from damage due to unexpected power surge...

Page 10: ... temperature and humidity is outside the specified limits in the Specifications Table 3 Connect to Mains Power Connect the AC input power cord to a socket outlet to power up the UPS The battery in the UPS will lose some charge during shipping and storage It will recharge completely after approximately 8 hours of normal operation Do not expect full battery run time during this initial recharge peri...

Page 11: ... cabac co nz W cabac co nz 11 11 of 21 Physical Appearance Front Panel Rear Panel Item Description 1 On Off Power Switch 2 LED 1 GREEN AC Normal Status LED 3 LED 2 YELLOW Battery Charging LED 4 LED 3 RED Battery State of charge LED 5 AC Power socket outlets 6 Phone Fax line Surge Suppressor 7 USB Communications Port 8 Input AC Fuse 9 Input Power Socket with Spare Fuse 1 2 3 4 5 6 7 8 9 ...

Page 12: ...ndicators Front Panel Indicator Buzzer Status Operational Description LED 1 Green LED2 Yellow LED 3 Red OFF ON OFF OFF UPS OFF Mains Normal Batteries Charging ON ON OFF 2 second Interval Beeping UPS ON Mains Mode OFF OFF BLINK Beeping every 5 seconds Mains not present Battery Backup mode OFF OFF ON 2 beeps per second i Low battery Voltage 4 beeps every 2 seconds ii Overload Continuous iii Short ci...

Page 13: ...ss the power switch to stop the beeping The alarm stops when the UPS returns to normal utility mode of operation Low Battery Beeping 2 times every 1 second In Backup mode when the battery energy runs low the UPS beeps rapidly until the UPS shuts down due to complete battery discharge Overload Beeping 4 times every 2 seconds When the UPS is overloaded all three LED s turn on and the buzzer beeps ev...

Page 14: ... 750W Input Characteristics Rated Input Voltage 230 240V Input Voltage Range 165 275 V Rated Input Frequency 50 Hz 10 Output Characteristics Rated Output Voltage 230V 10 Output Frequency 50 Hz 10 Output Waveform Modified Square Wave Power Factor 0 6 Change Over Time Typ 0 4ms Max 10ms Battery Information at 25 C Rating 1 x 12Vdc 7Ah 2 x 12Vdc 9Ah 2 x 12Vdc 9Ah Type Sealed Lead Acid Maintenance Fre...

Page 15: ...5mm x 124mm x 382mm Operating Temperature 10 C to 40 C Maximum Operating Relative Humidity 95 Relative Maintenance 1 With normal use a UPS battery will last 2 to 3 years depending on the number of discharges and operating ambient temperatures 2 Charge the UPS s battery every 3 months during extended storage 3 Disconnect the power during extended storage to avoid overcharge of the battery 4 Avoid o...

Page 16: ...les cabac co nz W cabac co nz 16 16 of 21 Software Installation In order to utilise the UPS to its full potential the monitoring software must first be installed Please install the software according to the following steps For information on how to operate the software refer to the On CD manual When the software CD is inserted The Autorun screen will come up Click Install Click NEXT ...

Page 17: ...istribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 17 17 of 21 3 Enter details as requested on this screen Your product serial number will be on the CD envelope Click NEXT 4 Choose the installation directory Click Next ...

Page 18: ... sales cabac com au W cabac com au A 8 Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 18 18 of 21 5 Select language English is Default Click NEXT 6 Software will Now Install ...

Page 19: ...A 8 Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 19 19 of 21 7 Installation is now complete Click FINISH 8 The program is now running For information on how to operate the software refer to the On CD manual ...

Page 20: ... No LED s on i Battery Discharged Sleep Mode Press the POWER button ON ii PCB failure Contact Service Agent UPS always at battery mode Power cord lose Re plug the power cord Line voltage too high too low or black out Normal condition PCB failure Contact Service Agent sBuzzer continuously sounding i Short Circuit Remove the non critical loads ii UPS Faulty Contact Service Agent UPS does not provide...