Please ensure you read the EZiSYSTEM
user manual before using this product.
This Quick Start Guide is NOT a
substitute for the User Manual.
1 Battery Level Indicator 5 Display Panel
2 LED Mode Indicator
6 On / Off Trigger
3
F
unction / Mode Select Key
4 LED Bar Display
7 Battery Compartment
Controls
:
Switch on the EZiCAT™ by lifting and holding the
On/Off trigger
Switching on activates a start-up test which checks
the display LEDs, speakers and batteries.
The battery light starts to flash when approximately
20% battery life remains. Change all batteries at
the same time using quality alkaline replacements.
The EZiCAT™
always
starts in POWER mode and
at maximum sensitivity for the safety of the
operator.
Pressing the
F
unction key changes the EZiCAT™
mode between Power, Radio, 8kHz and 33kHz
Generator modes. The selected mode is indicated
by the illuminated LED.
The central LED bar indicates signal strength and
the display will rise as a service is detected, giving
a peak reading when directly over the service.
Sweep Search
:
Mark out the site to be scanned.
In POWER mode cross the site from left to right,
keeping the EZiCAT™ upright.
DO NOT SWING
.
Mark any responses with marker paint, flags or
similar. CAUTION: Never drive pegs into the
ground over the service
Turn through 90° and repeat across the site.
Change to RADIO mode and repeat the process in
both directions.
1
2
3
4
7
5
POWER Mode
RADIO Mode
Sweep Search
Quick Start Guide
6