background image

TOOLS YOU WILL NEED

MATERIALS YOU MAY NEED

■  Gas line shut-off valve

■  Pipe joint sealant or UL-approved pipe thread 

tape with Teflon* that resists action of natural 

and propane gases

■  Flexible metal appliance connector (1/2” I.D.). 

A 5-foot length is recommended for ease of 

installation but other lengths are acceptable. 

Never use an old connector when installing a 

new range.

■  Flare union adapter for connection to gas 

supply line (3/4” or 1/2” NPT x 1/2” I.D.)

■  Flare union adapter for connection to pressure 

regulator on range (1/2” NPT x 1/2” I.D.)

■  Liquid leak detector or soapy water.

*Teflon: Registered trademark of DuPont

Flat-blade 

screwdriver

Pipe wrenches (2)

(one for backup)

Phillips 

screwdriver

Open-end or  

adjustable wrench

Pencil and ruler

Level

Drill, awl or nail

IN THE COMMONWEALTH 

OF MASSACHUSETTS

■  This product must be installed by a licensed 

plumber or gas fitter.

■  When using ball type gas shut-off valves, 

they shall be the T-handle type.

■  A flexible gas connector, when used, must 

not exceed 5 feet.

WARNING

FIRE OR EXPLOSION 

HAZARD

If the information in this manual is not followed 

exactly, a fire or explosion may result causing 

property damage, personal injury or death.
Installation must be performed by a qualified 

installer.
Read these instructions completely and carefully.
Installation of this range must conform with 

local codes, or in the absence of local codes, 

with the National Fuel Gas Code, ANSI Z223.1/

NFPA.54, latest edition. In Canada, installation 

must conform with the current Natural Gas 

Installation Code, CAN/CGA-B149.1 or the 

current Propane Installation Code, CAN/CGA-

B149.2, and with local codes where applicable. 

This range has been design-certified by 

CSA International according to ANSI Z21.1, 

latest edition and Canadian Gas Association 

according to CAN/CGA-1.1 latest edition.
When installing a gas appliance the use of 

old flexible connectors can cause gas leaks 

and personal injury. Always use a 

NEW

 

flexible connector.
Leak testing of the appliance shall be conducted 

according to the manufacturer instructions.
The range must be electrically grounded in 

accordance with local codes or, in the absence 

of local codes, in accordance with the National 

Electrical Code (ANSI/NFPA 70, latest edition). 

In Canada, electrical grounding must be 

in accordance with the current CSA C22.1 

Canadian Electrical Code Part 1 and/or local 

codes. See Electrical Connections in this section.
Do not install this product with an air curtain 

hood or other range hood that operates by 

blowing air down on the cooktop.  This airflow 

may interfere with operation of the gas burners 

resulting in fire or explosion hazard.

FOR YOUR SAFETY:

WARNING

 Before beginning 

the installation, switch power off at 

service panel and lock the service 

disconnecting means to prevent power 

from being switched on accidentally. 

When the service disconnecting 

means cannot be locked, securely 

fasten a prominent warning device, 

such as a tag, to the service panel.

If you did not receive an anti-tip bracket with your 

purchase, visit 

cafeappliances.com

 

(In Canada, 

cafeappliances.ca

).

Anti-Tip Bracket 

Kit Included

•  A child or adult can tip the range and be killed.
•  Install the anti-tip bracket to the wall or floor.
•  Engage the range to the anti-tip bracket by sliding the 

  range back such that the foot is engaged.
•  Re-engage the anti-tip bracket if the range is moved.
•  Failure to do so can result in death or serious burns

  to children or adults.

Tip-Over Hazard

WARNING

Installation Instructions

Range

Questions? Visit cafeappliances.com. In Canada, visit cafeappliances.ca.

BEFORE YOU BEGIN

IMPORTANT —

 

Save these 

instructions for local inspector’s use.

IMPORTANT 

 Observe all governing 

codes and ordinances.

IMPORTANT 

 Remove all packing 

material and literature from oven before 

connecting gas and electrical supply to range.

 

IMPORTANT 

 To avoid damage 

to your cabinets, check with your builder 

or cabinet supplier to make sure that the 

materials used will not discolor, delaminate 

or sustain other damage. This oven has been 

designed in accordance with the requirements 

of UL and CSA International and complies 

with the maximum allowable wood cabinet 

temperatures of 194°F (90°C).

Note to Installer

 – Be sure to leave these 

instructions with consumer.

Note to consumer

 – Keep these instructions 

for future reference.

Servicer

 – The electrical diagram is in an 

envelope attached to the back of the range.
Proper installation is the responsibility of the 

installer. 
Product failure due to improper installation is 

not covered under warranty.
Before installing your range on linoleum or 

any other synthetic floor covering, make sure 

the floor covering can withstand 180°F without 

shrinking, warping or discoloring. Do not install 

the range over carpeting unless a sheet of 

1/4” thick plywood or similar insulator is placed 

between the range and carpeting.

Mobile Home - Additional Installation 

Requirements

The installation of this range must conform 

to the Manufactured Home Construction and 

Safety Standard, Title 24 CFR, Part 3280 

(formerly the Federal Standard for Mobile 

Home Construction and Saftey, Title 24, 

HUD Part 280). When such standard is not 

applicable, use the Standard for Manufactured 

Home Installations, ANSI A225.1/NFPA 501A 

or with local codes.
In Canada, the installation of this range must 

conform with the current standards CAN/CSA-

A240-latest edition, or with local codes.
When this range is installed in a mobile 

home, it must be secured to the floor during 

transit. Any method of securing the range 

is adequate as long as it conforms to the 

standards listed above.

Rating plate

SINGLE OVEN

Summary of Contents for JGB660

Page 1: ...tch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a pro...

Page 2: ...CATIONS CONVERTING TO PROPANE GAS OR CONVERTING BACK TO NATURAL GAS FROM PROPANE This range leaves the factory set for use with natural gas If you want to convert to propane gas the conversion must be...

Page 3: ...ns have been made make sure all range controls are in the off position and turn on the main gas supply valve Use a liquid leak detector at all joints and connections to check for leaks in the system W...

Page 4: ...NG Never completely remove the leveling leg as the range will not be secured to the anti tip device properly Follow instructions supplied with ANTI TIP bracket Anti Tip Bracket Kit Included INSTALLATI...

Page 5: ...r nsito Cualquier m todo para asegurar la cocina es adecuado siempre y cuando se realice conforme con los est ndares que figuran a continuaci n ADVERTENCIA RIESGO DE INCENDIO O EXPLOSI N Si la informa...

Page 6: ...derecho 6 Lado izquierdo Altura m nima hasta la pared lateral 36 30 2 5 4 9 13 14 1 2 24 4 1 2 12 1 2 Pared Lateral Suministro de gas y electricidad CONVERTIR A GAS PROPANO O VOLVER A CONVERTIR DE PRO...

Page 7: ...das las conexiones se hayan realizado aseg rese de que todos los controles de la cocina est n en la posici n de apagado y encienda la v lvula de suministro principal de gas Use un detector de p rdida...

Page 8: ...la unidad y ajuste la altura de la pata trasera de modo que quede correctamente adherida Nivel de Agua NOTA La placa de cocci n debe estar a la misma altura o m s arriba que la mesada Mesada 0 o Super...