User Manual

CM510-62G & CM510-72F

This manual is suitable for:

Interface

Model

Terminal

CM510-62G

Terminal

CM510-72F

Xiamen Caimore Communication Technology Co.,Ltd

Add: 3F, 1st Building, 23# Wanghai Road, Xiamen

Tel

+86-592-3799895

Fax

0592-5975885 P

361009

Web

www.caimore.net

Email:oversea@caimore.com

版权所有

2003-2009

----

才茂通信 通畅天下

----

Summary of Contents for CM510-62G

Page 1: ...72F This manual is suitable for Interface Model Terminal CM510 62G Terminal CM510 72F Xiamen Caimore Communication Technology Co Ltd Add 3F 1st Building 23 Wanghai Road Xiamen Tel 86 592 3799895 Fax 0...

Page 2: ...unication technology co Ltd Trademark Caimore and other Caimore brands are possessed by Xiamen Caimore communication technology co Ltd Other brands or registered brands mentioned in this page are poss...

Page 3: ...r Supply 3 1 5 Detect The Network 3 2 1 Local Configuration 4 2 1 1 Center Server Config 5 2 1 2 PLC Connection Config 5 2 1 3 Device Net Config 6 2 1 4 Advance Config 7 2 2 Remote Configuration 8 Ann...

Page 4: ...e packed reasonably Please keep the package material when you open the box so as to use them again when before transporting in the future The components of DTU One unit CAIMORE DTU One power adapter O...

Page 5: ...he flow direction of this pin is DTU computer Input 6 TXD RS232 interface sender pin assuming DTU is connected to the computer the data flow of this pin is DTU computer Output 7 GND RS232 RS232 interf...

Page 6: ...ormer Notice When DTU changes information with base station the instantaneous current changes quickly and peak current is very large So it requires higher quality of external power supply transformer...

Page 7: ...re powering up 2 Configuration There are two configuration modes for DTU local configuration and remote configuration 2 1 Local Configuration 1 Connect your computer and DTU via DEBUG interface 2 Run...

Page 8: ...from model to model xx50 8 xx60 4 Center Server Address Set it to server s IP address or domain name If there is no static IP for server please use domain name Center Port Set it to server s port whic...

Page 9: ...is different from DTU to DTU Device SIM Num A eleven decimal number for server to identify different DTU Mobile number is used in UDP mode It is not necessarily to set mobile number as same as SIM car...

Page 10: ...econnection Interval It is interval time of trying to connect server again when DTU disconnect with center server The unit is second range is 15 360 Heart Packet Interval The interval to send heartbea...

Page 11: ...gistered packet Please set NONE in the value of custom registered packet 3 Set custom registered packet Please set corresponding string in the value of custom registered packet After setting please cl...

Page 12: ...rver s IP address AT PTSEC Configure sub server s IP address AT IPAD1 Configure 1st center s IP address AT PORT1 Configure 1st center s port AT IPAD2 Refer to 1st center s configuration AT PORT2 AT IP...

Page 13: ...time AT TCPMTU Configure packet size Commands to configure network AT APN Configure access point AT USERNAME Configure APN username AT PASSWORD Configure APN password AT CENT Configure APN center dial...

Page 14: ...ver during 60 seconds DTU will send a heartbeat packet to server to keep the connection The data format that DTU sends to server 1 Default registered packet ID PHONE_NUMB ER 0 IP_AD D ETX 4 byte 11 by...

Page 15: ...nnection The data format that DTU send to data center 1 Default registered packet Starting Mark Type Lengt h DTU Identify Code DTU IP Address Local Port Ending Mark 1 byte 1 byte 2 bytes 11 bytes 4 by...

Page 16: ...entify Code Ending Mark 1 byte 1 byte 2 bytes 11 bytes 1 byte 0x7b 0x81 0x10 0x7b Under UDP mode Xx60 does not respond the heartbeat packet by default Technical Support If there is any doubt please ac...