USER GUIDE
Operation Indicator Sounds and Lights
Sounds
Lights
Meaning
Successful Operation
Successful Programming
Operation Error
Low Battery Power
Default Setting Restored
In Programming Mode
1 Beep
2 Long Beeps
3 Beeps
5 Beeps
10 Rapid Beeps
Restore Default Settings
Press
R
Note:
Press the button for more than 5 seconds; the
programming is reset back to the original factory
codes once you hear 3 long beeps.
After restoring default settings, you must run the
door handing identifying process (#1) again before
programming any other functions.
R
Reset
button
Do not use any chemical liquid or lubricating oil with additives
to clean the lock body.
It will damage the surface or even mainboard.
The manufacturer warrants the product to be free from defects in material and workmanship for a period of 12
months from the original date of purchase. If you discover a defect in the product covered by this warranty, we will
repair or replace the item at our option using new or refurbished components.
EXCLUSIONS
This warranty covers defects in manufacturing discovered while using the products as recommended by the
manufacturer rather than occurred by the act of God, and damages caused by misuse, abuse, and unauthorized
modification.
LIMITED LIABILITY
The manufacturer will not be held liable for incidental or consequential losses or damages from any act of God.
Operational Interface
Battery Lid
Slide the lid to change the batteries.
Battery Holder
Four AA (1.5 V) alkaline batteries.
R Button (Reset)
Restore default settings.
Turn-piece
To lock/unlock the lockset from inside.
Programming Button
Lock Buttons
Cylinder
Washer
Prevents water from permeating into lockset.
Programming button is for setting function.
.
To lock/unlock the lockset
from outside.
Lock Button is for lock and unlock function
by key
Operating Instructions
10
Trouble shooting
After installing the lockset and batteries,
the door can’t be locked and three short
beeps are emitted when you press the
lock button.
The door-handing
identification process isn’t
yet complete.
Refer to step1.
When you are in the door-handing
identifying process, you get the red light
flashing three times, and three short
beeps.
Wrong door-handing or
change of the door-handing
in the memory.
Press the R button to restore the system
to factory default setting and re-execute
door-handing identifying process
(
step 1)
Refer to
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
You’ve installed the lockset and batteries,
but you still get no response when you
press any button.
Check to see if the battery polarities
have been reversed or if the battery is
dead.
If so, re-install or change the battery.
If not, please check to see if the cable is
properly connected.
Low battery.
Replace with new alkaline batteries.
Although you succeeded in the first
execution of the door-handing identifying
process, the latch still doesn’t work.
(i.e. You can feel the motor attempting to
run.)
The door can be locked normally, but
when you try to unlock it, you hear three
short beeps and the lock won't unlock
when you enter the user code and press
the lock button.
Warranty
Delete an Existing User Code
Delete All User Codes at Once
Default programming code (PC): 0000
Default user code (UC): 1234
Your new programming code (PC) ____________
Your new user code (UC) ___________________
The same programming code and user code cannot be accepted.
The lock will cease operation if unauthorized codes are entered
over 5 times.
The system will unfreeze after 45 seconds.
Door Handing Identification Process
The lock needs to learn if your door is a right-
or left-handed.
handed
Toggle Auto-Lock On/Off
Set Auto-Lock Time Delay
Create a One-Time User Code 4–10 Digits Long
1
4
5
6
7
8
9
Add New User Code
Change Programming Code
2
3
TOUCHPAD
ELECTRONIC DEADBOLT LOCK
Keep the door open while programming to avoid being locked out accidentally
.
The lock contains one factory-preset user code but can be programmed to store
up to a total of thirty additional unique user codes.
Codes can be added and deleted at any time. For first-time programming, use
factory default programming code. It’s recommended to change the default
programming code and default user code right after you install the lock.
Every programming step should be done within 6 seconds.
Code Input Error;
System Shuts Down
3 Long Beeps
Lock button flashes slowly
Note:
4–10 digits in length.
Up to 30 sets of user codes can be saved. User codes should be
Note:
user codes are deleted.
The lock can only be operated by key during that time.
Auto-locking and keypad locking functions will be invalid when
DO THIS FIRST
!
0
Enter PC
4
Enter PC
Enter
New PC
1
Enter PC
Enter
New UC
2
Enter PC
Enter
the UC you
want to
delete
3
Enter PC
Note:
user codes are disabled. The lock can only be operated by key
during the time. Repeat the steps to enable the user codes again.
Auto-locking and keypad locking functions will be invalid when
Note:
The one-time user code will automatically cancel after it is used
one time.
Note:
following instructions #7.
Repeat the steps in #6 to cancel the auto-locking function.
The preset delay-time is 30 seconds, you can change the time by
Note:
10–99 seconds delay-time available.
5
Enter PC
6
Enter PC
Enter
Seconds
(10~99)
7
Enter PC
8
Enter PC
Enter
One Time
Code
Batteries were installed
incorrectly and cable
connect incorrectly.
The functioning of the
micro-switch is abnormal.
Call our customer service department.
PL2S-2
(1) The depth of the latch
bolt hole is insufficient.
(2) The latch bolt is not
aimed at the opening
of the strike.
While the door is locked, you hear the
latch bolt coming out when you press the
to lock the door; however, three short
beeps are emitted.
Conversely, while the door is open, no
beeps are emitted when locking the
latch bolt.
(1) Dig the latch bolt hole for the strike
(2) Adjust the strike to the appropriate
position.
deeper.
The minimum depth is 1" (2.5 cm).
Enable/Disable All User Codes