Solar storage-to-boiler thermostatic connection kit

H0000850

www.caleffi.com

262 series SOLARINCAL-T
263 series SOLARINCAL-T

Plus

Installation 

Before installing a kit with mixing valve, make sure the system’s operating parameters fall within the mixing valve’s working parameters, for example
in terms of supply temperature and pressure etc..
The  kit  with  mixing  valve  must  be  installed  by  a  qualified  technician  in  accordance  with  established  legislation  and  the  instructions  given  in  this
manual.
The system in which the kit with mixing valve is going to be installed must be flushed and cleaned to remove any dirt that may have accumulated
during installation. Failure to remove impurities may affect valve performance and void the manufacturer’s warranty.
In case of highly aggressive water, it must be treated before entering the kit with mixing valve.
It is essential that access to the valve is not obstructed, in order to allow maintenance to the valve or fittings if required. The pipes must not be used
to support the weight of the valve
During the installation, observe all current legislation regarding the maximum distance between the valve outlet and each user taps.
The kit with mixing valve can be installed in any position, whether vertical or horizontal. 
The hot and cold water inlets to the valve must be connected as shown on the valve body itself.
The thermostatic mixing valves must be installed complete with shut-off valves, strainers and check valves at the hot and cold water inlets.
The shut off valves are required to enable the valve to be isolated for maintenance.
The strainers are essential to prevent impurities from entering the mixing valve.
The check valves are necessary to prevent undesired circulation and backflow.
The kit with mixing valve is supplied complete with strainers and check valves at the hot and cold water inlets.
If the kit with mixing valve is not installed according to these instructions, it may operate incorrectly and endanger the user.

Installation diagram 

Installation positions 

The  kits  can  be  installed  in  any  position,  vertically  or  horizontally.
An installation close to the boiler is recommended.

Bracketing

Anti-scald safety function

In  case  of  hot  or  cold
water  supply  failure  at
the  inlet,  the  obturator

shuts  off  the  water  flow,  thus
closing  the  mixed  water  oulet.
This performance is guaranteed
only 

when 

there 

is  a  minimum  temperature
difference between the inlet hot
water  and  the  mixed  water
outlet of 10°C.

INSTRUCTIONS  FOR  INSTALLATION,  COMMISSIONING  AND  MAINTENANCE

262 series

263 series

©  Copyright  2016  Caleffi