background image

QUICK START GUIDE

60 GHz cnWave™

System Release 1.1

Summary of Contents for cnWave V1000

Page 1: ...QUICK START GUIDE 60 GHz cnWave System Release 1 1 ...

Page 2: ...ngly any copyrighted material of Cambium its licensors or the 3rd Party software supplied material contained in the Cambium products described in this document may not be copied reproduced reverse engineered distributed merged or modified in any manner without the express written permission of Cambium Furthermore the purchase of Cambium products shall not be deemed to grant either directly or by i...

Page 3: ...Node 12 Mounting of 60 GHz cnWave products 13 60 GHz cnWave V1000 13 60 GHz cnWave V3000 V5000 15 Connecting 60 GHz cnWave Products 27 Installing PSU and powering the ODU 27 Installing the 60W DC power injector 28 Installing the AC DC PSU 29 Installing the V1000 power injector 30 Operation 31 Theory of operation 31 Configuration and Alignment 32 Nodes deployment 32 Glossary 33 Cambium Networks 34 ...

Page 4: ...ing Cambium Networks 60 GHz cnWave platform equipment This Quick Start Guide assists operators in acquiring a high level understanding of the 60 GHz cnWave platform hardware installation methods initial login procedures and safety warranty information ...

Page 5: ...s solutions at a significantly lower TCO than fiber infrastructure Service providers and enterprises now have access to Gigabit for business and residential connectivity backhaul for Wi Fi access Certified for Facebook Terragraph 60 GHz cnWave mesh solutions are highly efficient at handling high density deployments in cities and suburban areas V1000 V3000 Choice of two antenna sizes 40 5 dBi or 44...

Page 6: ...esponsible for l Familiarity with current applicable national regulations including radio regulations electrical installation regulations surge protection regulations and working at heights regulations l Installation following Cambium Networks instructions l Confirming that the equipment settings are compliant with national or regional regulations l Familiarity with training material available on ...

Page 7: ...ode NFPA 70 2005 and 780 2004 Installation of Lightning Protection Systems In Canada follow Section 54 of the Canadian Electrical Code These codes describe correct installation procedures for grounding the outdoor unit mast lead in wire and discharge unit size of grounding conductors and connection requirements for grounding electrodes Other regulations may apply in different countries and therefo...

Page 8: ...h bends and curves kept to a minimum l Grounding cables must not be installed with drip loops l All bends must have a minimum radius of 200 mm 8 in and a minimum angle of 90 A diagonal run is preferable to a bend even though it does not follow the contour or run parallel to the supporting structure l All bends curves and connections must be routed towards the grounding electrode system ground rod ...

Page 9: ...plied with a mounting plate and band clamp The mounting plate can be used for mounting the V1000 on a wall or it can be used with the band clamp to mount the V1000 on a pole with diameter in the range 40 mm to 77 mm 1 6 inches to 3 03 inches Figure 2 V1000 mounting plate and band clamp V1000 adjustable pole mount N000900L022A The adjustable pole mount is used to provide elevation adjustment when a...

Page 10: ...5 dBi or 44 5 dBi V3000 precision bracket C000000L125A The precision bracket Precision bracket figure below is used to mount the V3000 CN on a vertical pole with diameter in the range 25 mm to 80 mm 0 98 inches to 3 14 inches The precision bracket provides fine adjustment of up to 18 in azimuth and 30 in elevation for accurate alignment of the V3000 ...

Page 11: ...w 11 Figure 5 V3000 precision bracket C000000L125A V3000 precision bracket components Bracket body Azimuth arm Long 120 mm M8 screws and flange nuts Bracket base 40 mm M8 screws plain washers and Nyloc nuts V3000 mount ...

Page 12: ...V3000 CN or V5000 DN is mounted on a pole The tilt bracket works with poles with diameter in the range 25 mm to 80 mm 0 98 inches to 3 14 inches The tilt bracket Assembly may be used with third party band clamps to mount the ODU on larger pole with diameter in the range 90 mm to 230 mm 3 54 inches to 9 05 inches Figure 6 Tilt bracket assembly V5000 Distribution Node Figure 7 V5000 Distribution Nod...

Page 13: ...000 wall mount C000000L136A The Wall Mount Wall mount figure below is used to mount a V5000 DN on a vertical wall It does not provide azimuth or elevation adjustment The wall mount requires additional fixing hardware suitable for the type of wall Figure 9 V5000 wall mount Mounting of 60 GHz cnWave products 60 GHz cnWave V1000 V1000 pole mount The V1000 CN can be installed to a pole using the suppl...

Page 14: ...e V1000 wall mount Follow the below instructions to mount V1000 to the wall 1 Fix the mounting plate supplied with the V1000 ODU securely to a vertical wall using suitable fixings Note Fixing hardware is not supplied with the V1000 2 Slide the V1000 ODU onto the mounting plate from above ensuring that the spring clip in the mounting plate clicks into place on the radio ...

Page 15: ...elevation from boresight As long as the unit is installed with the remote node visible within this range no further adjustment is required 60 GHz cnWave V3000 V5000 V3000 precision bracket The precision bracket is used to mount the cnWave V3000 CN on a vertical pole providing fine adjustment up to 18 in azimuth and 30 in elevation for accurate alignment of the V3000 The precision bracket is compat...

Page 16: ...body The screws locate in the slots in the azimuth arm 2 Fit two flanged M8 nuts to the long screws on the back of the bracket Tighten using a 13 mm spanner 3 Insert the three medium length 40 mm M8 screws through the bracket base and the V3000 mount The screws locate in the slots in the bracket base ...

Page 17: ... circular hole in the V3000 mount 4 Fit plain washers and M8 Nyloc nuts to the screws on the back of the bracket base Tighten using a 13 mm spanner 5 Insert the two remaining long 120 mm M8 screws through the bracket body and the azimuth arm The screws locate in the slots in the bracket body ...

Page 18: ...acket body 6 Fit three sets of spacers plain washers and M8 Nyloc nuts to the screws on the underside of the bracket base Tighten using a 13 mm spanner 7 Attach the V3000 mount to the radio using the four short M6 bolts Tighten the four bolts to a torque setting of 5 0 Nm 3 7 lb ft using a 13 mm spanner or socket ...

Page 19: ...ng the clamp and the remaining flanged nuts Adjust azimuth approximately and tighten the nuts to 10 Nm 7 4 lbft using a 13 mm spanner 9 Lock the antenna alignment by tightening the five Nyloc nuts see step 5 and step 8 to 10 Nm 7 4 lbft using a 13 mm spanner or socket ...

Page 20: ...the telescope by looping the two elastic O rings over the ears of the mount ensuring that the telescope is located securely in the mount Precision bracket alignment 1 Ensure that the three Nyloc screws for securing the bracket in elevation are loose and the fine elevation adjuster is holding the weight of the unit 2 Ensure the two Nyloc screws for securing the bracket in the azimuth are loose ...

Page 21: ...hich attaches the bracket to the pole until there is enough freedom to rotate the unit in azimuth 6 From behind the unit using the sight to aim towards the remote node rotate the unit until it is approximately aligned in azimuth Tighten the clamp 7 While looking for the far node though the site rotate the fine elevation adjuster until the alignment is complete in the elevation plane One turn of th...

Page 22: ...o fix the elevation alignment and do the same for the two Nyloc screws for azimuth alignment to 10 Nm 7 4 lbft using a 13 mm spanner or socket V3000 tilt bracket assembly 1 Fix the mounting plate of the tilt bracket to the back of the radio using four of the short bolts ensuring that the arrow in the plate points towards the top of the radio Tighten the four bolts to a torque setting of 5 0 Nm 3 7...

Page 23: ...d tighten the nuts to a torque setting of 10 0 Nm 7 4 lb ft using a 13 mm spanner ensuring that the arrow in the body is pointing upwards 5 Fit the mounting plate to the bracket body by positioning the open ended slots over the short bolts Insert the remaining short bolts through the longer curved slots into the threaded holes in the bracket body Adjust the elevation angle and tighten the bolts to...

Page 24: ...lots in the bracket body Secure the bracket body to the pole using band clamps not supplied by Cambium ensuring that the arrow in the body is pointing upwards Adjust the azimuth angle and tighten the band clamps to a torque setting of 6 0 Nm 4 5 lb ft 3 Fix the mounting plate to the bracket body with four of the short bolts using a 13 mm spanner or socket Adjust the elevation angle and tighten the...

Page 25: ...ghten the four bolts to a torque setting of 5 0 Nm 3 7 lb ft using a 13 mm spanner or socket 4 Attach the pole mount bracket to the pole using the clamp and the remaining flanged nuts Adjust azimuth and tighten the nuts to 10 Nm 7 4 lbft using a 13 mm spanner V5000 alignment The V5000 distribution node has two sectors situated side by side each covering 140 degree range in azimuth giving a combine...

Page 26: ...adio using the four short M6 bolts ensuring that the arrow in the plate points towards the top of the radio Tighten the four bolts to a torque setting of 5 0 Nm 3 7 lb ft using a 13 mm spanner or socket 3 Insert the four short M8 bolts into the sides of the bracket body 4 Fit the bracket body to the mounting plate by positioning the short bolts into the open ended slots Tighten the bolts to a torq...

Page 27: ...oisture proof enclosure Do not locate the PSU in a position where it may exceed its temperature rating Attention Le bloc d alimentation n étant pas étanche placez le à l écart des sources d humidité que ce soit dans le bâtiment de l équipement ou dans une enceinte ventilée étanche à l humidité Ne placez pas le bloc d alimentation dans une position où il pourrait dépasser sa température nominale At...

Page 28: ...imentation CC dans la connexion Ethernet entre le bloc d alimentation et l ODU l Ne branchez aucun périphérique autre qu un bloc d alimentation cnWave Cambium 60 GHz dans le port PSU de l ODU Brancher tout autre périphérique sur le port PSU de l ODU peut endommager l ODU et le périphérique Installing the 60W DC power injector Connect the 5 GbE port to ODU and 5GbE LAN port to the network equipment...

Page 29: ...9 Installing the AC DC PSU l Connect the Input side of the AC DC PSU to the AC power line l Connect the Output side of DC PSU to ODU through cable joiner and DC mini adapter Figure 3 AC DC PSU N000000L179B Figure 4 AC DC powering diagram ...

Page 30: ...GHz cnWave Products 30 Installing the V1000 power injector l Connect the 56V Gigabit Data Power port to ODU and Gigabit Data port to the network equipment Figure 5 V1000 power injector Figure 6 V1000 powering diagram ...

Page 31: ...ution of traffic between the nodes and higher availability of the traffic This will also overcome non Line of sight issues Devices use TDMA TDD technology to achieve density deployment efficiency The Network and the nodes are configured controlled and monitored by a cloud based E2E controller Following terminology is used for the network deployment l Distribution node DN DN connects with other DN ...

Page 32: ...r the first PoP node must be configured manually since connectivity to the E2E controller has not yet been established After establishing communication with the E2E controller the nodes report a hash of their local configuration file and the controller automatically pushes configuration changes to the nodes upon seeing any mismatches Centralized configuration management architecture implemented in...

Page 33: ...Glossary 33 Glossary Term Definition CN Client Node DN Distribution Node E2E Controller End to End Controller ...

Page 34: ...rks around the world our PMP access network solutions prove themselves day in and day out in residential access leased line replacement video surveillance and smart grid infrastructure applications Cambium Networks solutions are proven respected leaders in the wireless broadband industry We design deploy and deliver innovative data voice and video connectivity solutions that enable and ensure the ...