background image

Page 1 of 8

CX-ED1259L 

‘RIM’ Electric Strike

INSTALLATION INSTRUCTIONS

Electrified Locks, Relays and Timers

(1) 4-PIN power connector
(1)  3-PIN door status  

connector

(2) M5 self tapping screws

(4) 14-20 x 1 1/2" screws
(2) 10-32 x 1" screw spacers
(4) 4-40 x 1/4" screws
(1) MOV

(2) 1/8" S/S Spacers Plates
(1) Cover plate
(1) Install Jig

THIS PACKAGE INCLUDES:  

1. DESCRIPTION 

Camden CX-ED1259-L Grade 1 RIM strike for pullman latches 
offers the very best strike quality and performance. The strike 
design delivers unparalleled application flexibility, with field 
selectable voltage, fail safe/fail secure operation and mechanical 
adjustment of the strike body. 

2. SPECIFICATIONS

Voltage 

12/24V AC/DC

Current Draw

280mA@12V DC 

140mA@24V DC

Static Strength

1,500 Lbs.

Dynamic Strength 

70 Ft-Lbs.

Endurance 

1,000,000 Cycles (Factory Tested) 

250,000 Cycles (UL Verified)

Latch Protection

1/2" - 3/4"

Fire Rating

UL 10C/CAN4-S104 

3 hrs. (Fail Secure Only)

Mode

Field Selectable 

Fail Safe/Fail Secure

Mech. Adjustment

Strike Body

Operation

AC-Buzz, DC-Silent

Duty

Continuous

Latch Bolt Monitor

SPDT, 100mA @ 24V DC

Dimensions (Body)

9" H x 1 3/4" W x 1/2" D 

(230mm x 45mm x 12.7mm)

3. DIMENSIONS 

UL 1034
UL 294

UL10C/
CAN4-S104,
3hr. Fire rating

1/2”

(12.7 mm)

1 3/4”

(45 mm)

9”

(230 mm)

Summary of Contents for CX-ED1259L

Page 1: ...tion flexibility with field selectable voltage fail safe fail secure operation and mechanical adjustment of the strike body 2 SPECIFICATIONS Voltage 12 24V AC DC Current Draw 280mA 12V DC 140mA 24V DC...

Page 2: ...he benefit is that once installed Camden s RIM strike will not move out of alignment and require a service call a common occurrence with competitive RIM strikes CX ED1259L is the only thick UL Fire li...

Page 3: ...4 5 Jamb Hole punch Hole punch Holes for self tapping screws Connecting wire hole 5 8 Connecting wire hole A A B Note 1 Open door slightly and remove the template Note 1 Use a Hole punch on marked po...

Page 4: ...ne shim The crash bar should only touch this shim not apply pressure when the door is closed 4 While adjusting strike allow a small gap between strike body and crash bar approx 1 8 Mark remaining scre...

Page 5: ...NOTE The products are intended to be installed in accordance with the installation wiring diagram mechanical assembly drawings provided with each product the local authority having jurisdiction AHJ an...

Page 6: ...IRES ORANGE GREY WHITE Or 2 4 V 1 2 V Step 4 Setting Fail Secure Fail Safe Product is factory set to fail secure To change from fail secure to fail safe 1 Loosen the screw at the back of the Electric...

Page 7: ...offer horizontal adjustment to compensate for doors that are misaligned with the door frame but there is a limit to the strike adjustment Check that the door is not binding on the frame An electric st...

Page 8: ...jaws of the strike will improve the operation but please be careful not to over spray Consideration for a professionally finished retrofit installation Replacing electric strikes used with cylindrica...

Reviews: