1. GENERAL DESCRIPTION

The all-new Camden CX-WC17VR-PS Restroom Control Kit now comes with 

the CM-221 Hands-Free Switch, which uses active infrared microburst sensor 

technology and is designed to be used in ADA-compliant automatic door control 

applications and access control. The CM-221 switch eliminates the spread of 

germs by avoiding physical contact and provides greater convenience when 

moving through the premises. For smooth operation, the CM-221 has an 

adjustable time delay of 0.5 to 20 seconds and an adjustable range of 2” to 8”  

(5cm to 20cm).
 

The CX-WC17VR-PS Restroom Control Kit is controlled by Camden’s advanced 

relay logic controller, the CX-33. Camden’s CX-33 is a ‘state of the art’ logic relay 

designed to support virtually any automatic door application.

The designation “PS” in the part number reflects that this kit now comes pre-

wired in a metal enclosure with a power supply that is ready to accept all field 

wiring.

Operation at a Glance

The CX-WC17VR-PS has two modes: Mode 7 and Mode 8. The first mode refers 

to the “Normally Unlocked” condition, when the exterior PUSH to OPEN column 

switch is pressed or waved, it triggers the door operator to open the door. 

However, the second mode refers to the “Normally Locked” condition, when the 

exterior PUSH to OPEN column switch is pressed or waved, it first unlocks the 

strike and triggers the door operator to open the door.
Inside the restroom, if the PUSH to LOCK column switch is pressed or waved, it 

keeps the door locked in either mode and disables the exterior PUSH to OPEN 

column switch. The LED light ring on the column switches turns red, indicating 

the restroom is occupied. The user can either press or wave PUSH to UNLOCK 

column switch as they exit the restroom. The LED light ring on the column 

switches turns green, indicating the restroom is now available to be used.

Note:

 While exiting, the user can also use a crash bar, paddle, or doorknob 

to unlock the door; in this case, the system will reset to its initial condition (mode 

7 or mode 8), and the red light will turn green, allowing other users to use the 

restroom.

2. MODE SETTING

CX-WC17VR-PS SERIES RESTROOM KIT

INSTALLATION INSTRUCTIONS

Mode Selection

Mode selection depends on the user requirements;
•  If the user wants restroom to be unlocked during idle state, use Mode 7.
•  If the user wants restroom to be locked during idle state, use Mode 8.

Note:

 The default mode for the CX-WC17PS is Mode 7 

(normally 

unlocked).

There are three LED displays that will allow you to see what mode you 

have selected when advancing through the modes. To change the mode of the 

CX-WC17PS, simply press the MENU button once and use the UP button to 

advance to the desired mode. 

Mode Editing

Camden builds in typical times for lock release and door operator activation 

is ready to use without changing any parameters. If you need to change the 

timing or delay for an output, it can be done by pressing the “MENU” button 

within the mode you selected. Once the option is selected, you can use the 

“UP or DOWN” buttons to select the timing needed. The first option (H & 1 

flashing) will be how long relay 1 will be activated for (0-50 seconds). The 

second option (d & 1 flashing) will be how long to wait before activating relay 

2 (0-15 seconds). The third option (H & 2 flashing) will be how long relay 2 

will be activated for (0-50 seconds). The fourth option (d & 2 flashing) will be 

how long to wait before activating relay 3 (0-15 seconds). The fifth option (H 

& 3 flashing) will be how long relay 3 will be activated for (0-50 seconds). See 

the table 2.1

Factory Reset (Defaulting the CX-33)

To return the CX-33 back to its factory default settings, you will need to 

remove the power, then hold down the “MENU” button while powering 

up the CX-33. Once started, you will see the firmware version listed then a 

number “1” will be displayed. Reconnect your power and press the “MENU” 

button once, then use the “UP” or “DOWN” button to advance to the desired 

mode.  
For proper functionality, fully test the operation of the CX-WC11PS.

Display (M)

Description (Mode you are in)

Parameters (1-15 )

H, then 1

Relay 1 Hold Time

0.0 to 50 seconds

d, then 1

Relay 2 Delay Time

0.0 to 15 seconds

H, then 1

Relay 2 Hold Time

0.0 to 50 seconds

d, then 1

Relay 3 Delay Time

Depends on Mode

H, then 1

Relay 3 Hold Time

0.0 to 50 seconds

d

Sets the display ON or OFF during operating mode

ON or OFF

A

Input delay on Activate. If other than 0.0 is selected, the input must 

be held in for the time period chosen before the CX-33 will activate.

0.0 to 10 seconds

1

Set Dry Input 1 to activate on normally open or normally closed contact.

N/O OR N/C

2

Set Dry Input 2 to activate on normally open or normally closed contact.

N/O OR N/C

3

Set Dry Input 3 to activate on normally open or normally closed contact.

N/O OR N/C

4

Set Dry Input 4 to activate on normally open or normally closed contact.

N/O OR N/C

5

Set Dry Input 5 to activate on normally open or normally closed contact.

N/O OR N/C

Page 1 of 9

Page 2 of 9

Table 2.1 Different Modes for WC17VR-PS

3. CM-7536VR COLUMN SWITCH INSTALLATION

Code Requirements: If installed according to these instructions the CM-7536VR Column switch will meet the requirements of the California Building Code (Section 

1117B.6, Date: 2009), and Section 3.8.3.3.17(b) of the Ontario Building Code.

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS

DRAWING IS THE SOLE PROPERTY OF

CAMDEN DOOR CONTROLS.  ANY

REPRODUCTION IN PART OR AS A

WHOLE WITHOUT THE WRITTEN 

PERMISSION OF CAMDEN DOOR

CONTROLS IS PROHIBITED.

5502 Timberlea Blvd.

Mississauga, ON  Canada

L4W 2T7

Tel: (905) 366-3377

www.camdencontrols.com

CM-7536 With Touchless 

Sensor CM-221

01/12/23

Angelo R.

CUST

CM-7536VR

3758''

 [955.04mm]

6''

 [151.13mm]

134''

 [44.28mm]

2012''

 [520.70mm]

24''

 [609.60mm]

3534''

 [909.32mm]

338''

 [85.17mm]

Installation Steps:

1. Take out pre-assembled unit from the box. To mount the switch, it 

is required to disassemble a few components. Firstly, remove two 

Phillips screw holding the top End Cap in place. Once both screws are 

removed, take out the cap. Then, carefully pull out actuation bar and 

place it aside so as to protect it from any surface damage.

D

C

B

A

A

B

C

D

1

2

3

4

5

6

7

8

8

7

6

5

4

3

2

1

NEXT ASSY

USED ON

APPLICATION

MATERIAL

DRAWN

CHECKED

ENG APPR.

MFG APPR.

Q.A.

COMMENTS:

DATE

NAME

TITLE:

SIZE

B

DWG.  NO.

REV

SCALE: 1:1

UNLESS OTHERWISE SPECIFIED:

SHEET 1 OF 1

DO NOT SCALE DRAWING

DIMENSIONS ARE IN INCHES

TOLERANCES:

FRACTIONAL

± 1/64

ANGULAR: MACH

±0.5

   BEND

±

TWO PLACE DECIMAL

± 0.010

THREE PLACE DECIMAL

± 0.005

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS

DRAWING IS THE SOLE PROPERTY OF

CAMDEN DOOR CONTROLS.  ANY

REPRODUCTION IN PART OR AS A

WHOLE WITHOUT THE WRITTEN 

PERMISSION OF CAMDEN DOOR

CONTROLS IS PROHIBITED.

5502 Timberlea Blvd.

Mississauga, ON  Canada

L4W 2T7

Tel: (905) 366-3377

www.camdencontrols.com

End Cap

Actuation Bar

2. Determine/Mark the optimum height and mounting location from the 

finished floor to mount the column switch.  See the illustration below 

for the dimensions of the column switch.

3. Center the touchless switch over the box for wire connection, while 

lining up the top edge with your mark (If installing through an in-wall 

electrical box), drill a Ø 0.25” hole for wire connection (If installing 

without an in-wall electrical box).

Figure 3.1 End Cap and Actuation Bar removal

Figure 3.2 Dimensions

Summary of Contents for CX-WC17VR-PS Series

Page 1: ...eturn the CX 33 back to its factory default settings you will need to remove the power then hold down the MENU button while powering up the CX 33 Once started you will see the firmware version listed then a number 1 will be displayed Reconnect your power and press the MENU button once then use the UP or DOWN button to advance to the desired mode Forproper functionality fully testtheoperationoftheC...

Page 2: ... WITHOUT THE WRITTEN PERMISSION OF CAMDEN DOOR CONTROLS IS PROHIBITED 5502 Timberlea Blvd Mississauga ON Canada L4W 2T7 Tel 905 366 3377 www camdencontrols com A OLISA 24 03 22 CUST Wave Switch wire Cut out Drill a Ø 0 250 Hole Wall In wall Electrical Box Wall Mounting without in wall electrical box Mounting with in wall electrical box 2 1 2 64 77mm CM 7536VR Hands Free Column switch CM 7536VR Han...

Page 3: ...stor is provided to protect strike from spikes Connect varistor between input wires Fail Safe Changing Fail Secure 24VDC Red 24V Black Blue Green Ground How to modify fail safe to fail secure or vice versa 1 Loosen the screw as per the product diagram below 2 Rotate the set plate 180 and slide the plate until it is properly seated 3 Tighten the screw Note For UL 294 UL 1034 compliance the door str...

Page 4: ... magnet 120 VAC N C Model 60 40E033 AC AC Outside Push To Open Inside Push To Open Push To Lock DPS NC DPS COMM WET INPUT Lock Strike Strike Door Operator Green LED Red LED VDC VDC PUSH TO OPEN MOV Door Operator PUSH TO OPEN PUSH TO LOCK 12 to 24 V DC 0 V DC Ground Green LED Red LED Relay Normally Open Relay Common Relay Normally Closed CM221 Mode Pins OPEN Default position Internal mode LED color...

Page 5: ...ed LED Relay Normally Open Relay Common Relay Normally Closed CM221 Mode Pins OPEN Default position Internal mode LED colors will be controlled by the IR Sensor SHORTED Extermal mode LED colors will be controlled by Yellow and White wires Distance Adjustment 2 to 8 5 to 20 cm Turn clockwise to increase range Time Adjustment 0 5 to 20 seconds For ToggleTurn clockwise to increase time delay CM 7536V...

Page 6: ...UIRED BUT NOT INCLUDED WITH THE CX WC17VR PS 6 DOOR OPERATOR SUPPLIED BY OTHERS 3 B A C 6 A 1 CX WC17VR PS OPERATION A THE DOOR IS NORMALLY CLOSED AND UNLOCKED B OPERATING THE EXTERIOR ACTIVE SWITCH OPENS THE DOOR C ONCE INSIDE AND THE DOOR IS CLOSED PRESSING THE COLUMN SWITCH WITH THE LOCK SYMBOL AND PUSH TO LOCK LOCKS THE DOOR THE LIGHT RING AROUND THE VALUEWAVE HANDS FREE SWITCH TURNS FROM GREE...