Page 1: ...INSTALLATION AND OPERATION G4040E G4040IE AUTOMATIC BARRIERS FA00132 EN English EN...

Page 2: ...ARRIER MUST BE CONNECTED TO AN EFFECTIVE REGULATION GROUNDING SYSTEM THE MANUFACTURER DECLINES ANY LIABILITY FOR USING NON ORIGINAL PRODUCTS WHICH WOULD RESULT IN WARRANTY LOSS ALL MAINTAINED ACTION C...

Page 3: ...hed stainless steel set up for accessories Intended use The automatic barrier is designed for private and public parking facilities Any installation and or use other than that specified in this manual...

Page 4: ...om attachment cover 5 Protective casing shear proof 6 Cabinet 7 Anchoring pin 8 Control panel 9 Boom setting mechanical stop 10 Lever arm 11 Gearmotor with encoder 12 Inspection hatch 13 Anchoring bra...

Page 5: ...e electric cables to pass through making sure they are protected from any mechanical damage Tools and materials Make sure you have all the tools and materials you will need for installing in total saf...

Page 6: ...mpletely fastened Preparing the fastening plate If the flooring does not allow for a sturdy fastening of the entry unit you will have to set up a cement slab Dig a hole for the foundation frame Set up...

Page 7: ...atch Warning The barrier is set up for installing on the left When installing on the right invert the boom s opening direction as follows remove the anchoring pin from the lever arm release the gearmo...

Page 8: ...te and motor shaft plate with a screw Leave the screw loose to then facilitate fitting the boom To mount with the G03750 boom you will need to fit the G03756 reinforcement Attachment plate Mid plate B...

Page 9: ...ny time and without notice Fit the boom into the boom attachment cover and fasten it using the screws Cut the groove cover profiles to measure and fit them into the grooves on both sides of the boom F...

Page 10: ...ease the gearmotor and position the boom vertically Lock the gearmotor again Tighten the eyelet rod under the spring The spring should be screwed to the anchoring pin PASSAGE CLEARANCE 8 max 3 75 m Th...

Page 11: ...t notice Fasten the counter nut and lock the gearmotor again Check the proper working state of the spring With the boom raised vertically the spring is not taut With the boom lowered horizontally the...

Page 12: ...rd connector 13 AF card connector 14 Antenna terminal 15 Terminals for control and safety devices 16 Terminals for paired alternate CRP connections 17 Keypad selector terminal 18 Terminals for transpo...

Page 13: ...pply Terminals for powering up accessories a 24 V AC normally a 24 V DC when the emergency batteries are operating Overall allowed power 40 W Transformer Red White Blue Orange 24 V DC gearmotor with e...

Page 14: ...ed select 0 Deactivated from function F1 OPEN CLOSE INVERT function step step from control device NO contact Keypad selector Transponder or card reader Fit the R700 decoding card for recognition of th...

Page 15: ...devices C9 immediate closing with obstruction wait when closing Closing the boom after a vehicle has passed through the operating area of the safety devices During the closing phase the devices also p...

Page 16: ...16 16 Manual code FA00132 E N E N v 2 2 08 2016 CAME Cancelli Automatici S p A The data and information in this manual may be changed at any time and without notice Sleep Mode The Sleep mode function...

Page 17: ...the stop with a counter nut Establishing the endstop points Close the inspection hatch and power up the system Activate the barrier to check whether the boom is parallel to the road surface when close...

Page 18: ...ENTER also for the submenus use the arrow keys to select To increase or reduce the value use the arrows to exit the menu wait 10 seconds or press ESC the press ENTER to confirm Browsing the menu then...

Page 19: ...ctions F 50 Saving data in memory roll F 51 Reading memory roll data F 52 Transferring parameters from Master to Slave F 60 Sleep Mode function F 61 Pre flashing function U 1 Type of command to associ...

Page 20: ...ing and closing The cycle lamp stays on from the moment in which the barrier starts opening until it closes completely including the automatic closing time In case the automatic closing is not inserte...

Page 21: ...avel Percentage adjustment of the boom s total travel from the beginning of the opening slow down point Warning The percentage varies depending on the boom type for jointed booms of 2 m and 4 m set th...

Page 22: ...oom type The choice of boom type limits certain speed slow down and calibration limits This is to safeguard the entire barrier A 2 Motor test 0 Disable 1 Activate To verify the boom s proper rotating...

Page 23: ...s ENTER to confirm that the barrier has cali brated itself automatically Travel calibration Before doing a travel calibration establish the boom type check that the boom is balanced and that the maneu...

Page 24: ...NTER to confirm 2 Select a command to associate to the user The commands are step step open close 1 open 3 partial opening pedestrian 4 The partial pedestrian command appears only of function F 49 is...

Page 25: ...Memory Roll Card To memorize user data and configure the system to then reuse them with another control board even on another system RELEASING THE BOOM This procedure must be done with the main power...

Page 26: ...MASTER control panel Important Deactivate function F 19 automatic closing time on the SLAVE barrier s control panel Configuring the MASTER operator Select function F 49 Press ENTER to con rm Select 1...

Page 27: ...the MASTER barrier ALTERNATE CONNECTION Important Start by performing the following procedures on both operators t the RSE card with DIP switches sent to OFF onto the control panel connector of both b...

Page 28: ...e power supply and fuses The barrier does not perform automatic closing 11 12 13 4 The NC contacts are open The barrier does not work with the transmitter 2 14 16 6 Deactivate the MASTER SLAVE functio...

Page 29: ...ion in this manual may be changed at any time and without notice Periodic maintenance Before doing any maintenance cut off the power supply to prevent any hazardous situations caused by accidental boo...

Page 30: ...__________________ Fitter s stamp Name of operator Job performed on date Technician s signature Requester s signature Job performed ____________________________________________________________________...

Page 31: ...e disposed of as solid urban waste and simply separated from other waste for recycling Always make sure you comply with local laws before dismantling and disposing of the product DO NOT DISPOSE OF IN...

Page 32: ...3079 Sesto al Reghena Sesto al Reghena Pordenone Pordenone Italy 39 0422 4940 39 0422 4941 39 0434 698111 39 0434 698434 E n g l i s h E n g l i s h Manual code FA 0 013 2 E N FA 0 013 2 E N v 2 2 08...

Reviews: