INSTALLATION MANUAL

 

ZL90

CONTROL PANEL

FOR 24V OPERATORS

 English

EN

8(1

Summary of Contents for ZL90

Page 1: ...R Q W U R O V O L Q H Z 24 SERIES INSTALLATION MANUAL ZL90 CONTROL PANEL FOR 24V OPERATORS English EN 8 1...

Page 2: ...nsulation rating II Material ABS Protection rating IP54 operating temperature 20 55 C This product is engineered and manufactured by CAME cancelli automatici s p a and complies with current safety reg...

Page 3: ...M1 motor fuse 2 M2 motor fuse 3 Line fuse 4 Accessories fuse 5 Control unit fuse 6 Buttons for calibrating the stroke 7 Buttons for memorising the radio 8 code Control and signalling LED unit 9 Funct...

Page 4: ...ted with extra insulation as compared to the other conductive parts inside Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical...

Page 5: ...the connected devices and according to the CEI EN 60204 1 standards For connections that require several sequential loads the sizes given on the table must be re evaluated based on actual power draw a...

Page 6: ...NGLISH Power supply 230V a c 50 60 Hz Terminals for powering the following accessories 24V a c normally alternated power 24V a c continuous power when the emergency batteri es are in operation Overall...

Page 7: ...will start to blink c when the led stays on after about 5 seconds the procedure is complete d set to the dip switches back to OFF or to the previous position which depends on the functions selection...

Page 8: ...ct causes reversal until total opening is obtained partial stop N C socket input for safety devices such as photocells sensitive edges and other EN 12978 compliant devices Halts moving gate leaves and...

Page 9: ...P switch 8 to ON to activate test operation IMPORTANT when running the safety test function the N C contacts if unused should be excluded on the relative DIP switches see chapter 7 selecting functions...

Page 10: ...ter a total safety stop or during a power outage 2 ON Open stop close stop function with button 2 7 and remote control with built in radiofrequency card 2 OFF Open close inversion function with button...

Page 11: ...between the photocells that are set to the PARTIAL STOP or OBSTACLE STAND BY function Led CY Led PROG Led ALIM Led STOP Led CX TH 9 Signal LED Trimmer ACT Adjusts the waiting time when gate is open On...

Page 12: ...s to be half way open block the gearmotors again 10 1 PRELIMINARY ASSESSMENT OF THE DIRECTION OF MOVEMENT DURING OPENING Otherwise 1 if the gate leaves close invert the M N phases on either of the gea...

Page 13: ...ATIC CALIBRATION OF THE GEARMOTORS The gate leaf of the second gearmotor perform a closing run and an opening run With gate leaves fully ope the PROG LED stays on for some seconds to show the proper a...

Page 14: ...p a to notify users ENGLISH 11 Activating the remote control AF card Lock the radiofrequency card into the electronic card AFTER CUTTING OFF THE POWER SUPPLY or after disconnecting the batteries N B...

Page 15: ...AT01 AT02 AT04 CAME CAME CAME TWIN TWIN2 TWIN4 Pag 15 15 Manual code 319U16 319U16 ver 1 0 1 0 11 2011 CAME cancelli automatici s p a The data and information reported in this installation manual are...

Page 16: ...ronic card pressed The LED ashes 2 Press the transmitter button you wish to memorise The LED will stay on to show memorisation has been successful LED flashing LED on 11 4 MEMORISATION CH1 Channel for...

Page 17: ...rms that specialise in their proper disposal MANUFACTURER S DECLARATION OF CONFORMITY Pursuant to annex II A of the Directive 2006 95 CE CAME Cancelli Automatici S p A via Martiri della Libert 15 310...

Page 18: ...tion Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11345 NW...