background image

 

 

TECHNICAL MANUAL 

 City M

 

 

www.camfil.com 

City M/Manual, 

 

 

 Ver. 001 

 

September 2014

 

    

1

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for CITY M

Page 1: ...TECHNICAL MANUAL City M www camfil com City M Manual Ver 001 September 2014 1 ...

Page 2: ...G DRAWING 6 9 SAFETY INSTRUCTIONS 7 8 10 DESIGN 8 10 1 CONSTITUENT STANDARD COMPONENTS 8 11 TRANSPORT AND UNPACKAGING 8 10 2 AIR FLOW DETAILS 9 12 STARTING UP YOUR AIR PURIFIER 10 12 1 POSITIONING 10 12 2 SYSTEM INTEGRATION 10 12 3 ELECTRICAL CONNECTION 11 14 PRODUCT AND THE ENVIRONMENT 13 14 1 FILTERS AND THE ENVIRONMENT 13 15 MAINTENANCE 13 16 INSTRUCTIONS FOR REPLACING FILTERS 13 14 16 1 FILTER...

Page 3: ...After these there are illustrated texts about the various parts that make up this product The user manual also includes details of safety procedures associated with the use of the machine 3 Version history Version Date Signature Altered 001 See approval Initial version 4 Identification plate All Camfil City M air purifiers have the identification plate at the power supply to the unit 5 Guarantees ...

Page 4: ... air purifier Important Before using your high quality air purifier it is important that you as the user 1 read this User Manual 2 read the fan instructions and 3 follow the safety instructions in both documents 7 Technical specifications External dimensions vertical model Height 703 mm Width 329 mm Depth 338 mm Weight 16 kg including new filters Filter weight 4 3 kg 2 filters are needed 7 1 Fan s...

Page 5: ...ospitals and schools 9 Safety instructions Read the technical manual and follow the instructions The machine s power supply has to be disconnected during installation servicing maintenance and filter replacement CAUTION Pull out the electrical connector or use the safety switch when working on the product The machine is not to be regarded as de energised until 5 minutes after disconnection from th...

Page 6: ...ust not be used in environments where burning smouldering objects can get into the machine 9 The unit must be used indoors only 10 The unit must be used in the 25 C 60 C temperature range only 11 The unit must not be drenched with water The highest permitted humidity is 85 if a carbon filter is used 12 Follow the filter handling and replacement instructions very carefully Incorrect handling can da...

Page 7: ...bjects are used to unpack the product be careful not to damage the machine s cables and design finish Take special care when handling the filters See the filter replacement section Check that the product has not been damaged during transport Report any transport damage to the carrier Check also that the delivery is complete 10 2 Air flow details ...

Page 8: ...see figure below how to operate Controller card description Press increase the airflow the blue led indicators will guide you to what airflow you have chosen Press minus to lower the airflow A red warning light will be lit at the filter change symbol when it s time for filter replacement When the red warning light have been lit and filter are replaced you need to calibrate the unit by press an at ...

Page 9: ...rnal electrical systems must only be carried out by appropriately qualified persons using equipment supplied by Camfil The unit must only be connected to the network voltage stated on the machine plate identification plate 14 Product and environment The air purifier is made from lead free components It can be recycled Used models must always be sent to a recycling station for correct recycling and...

Page 10: ...the manufacturer of the respiratory protection Used filters may contain harmful substances and particles With incorrect handling these can escape to the environment and present risks of sickness and ill health Filters should be replaced on a continuous basis See Camfil AB s recommendations concerning the frequency of filter replacements 16 1 Filter replacement Always use protective gloves and resp...

Page 11: ...wards you Put the filter in a plastic bag Do the same procedure on the other filter and put it in a plastic bag 5 Take a new HEPA filter out of its box NB Do not touch the filter s surface Hold the handle only Put the filter in its positioning press it down and against the pattern of holes The black gasket must be towards the hole pattern of the unit Do steps 1 5 in reverse order ...

Page 12: ...achinery Directive 2006 42 EC the Low Voltage Directive 2006 95 EC and the EMC Directive 2004 108 EC Note that correct observance of the installation and safety instructions is a precondition for the compliance of all operating properties For more details of technical specifications the standards that have been complied with and Camfil s patents please contact Camfil 19 ...

Page 13: ...nother A calibrated particle counter can be used to examine the quantity of particles in the air By subscribing to this service you as our customer will always have a particle counter on location that is connected to a computer monitoring the indoor environment When an abnormal particle distribution is identified or in cases of other suspected problems we perform an analysis with a scanning electr...

Page 14: ...nuclear power stations Camfil Farr is a global company with 29 subsidiaries 23 production plants and an extensive network of agents in Europe the Americas and the Asia Pacific region CamCleaner CamCleaner is synonymous with high efficiency purification energy savings and almost silent operation Unlike all other air purifiers on the market our HEPA filters offer a degree of purification that can el...

Reviews: