background image

please call 1-800-543-6400 for customer 
assistance. Have the serial number, 
model number, and parts list (with 
missing parts circled) before calling.

General Safety Information

CalIfornIa propoSItIon 65

 

This product or  

  its power cord may 

contain chemicals known to the State 
of California to cause cancer and birth 
defects or other reproductive harm. 
Wash hands after handling.
 

You can 

  create 

dust when you cut, sand, drill 
or grind materials such as 
wood, paint, metal, concrete, 
cement, or other masonry. This dust 
often contains chemicals known to 
cause cancer, birth defects, or other 
reproductive harm. Wear protective 
gear.

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. 
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or 
property damage! Retain instructions for future reference.

For parts, product & service information

visit 

www.chpower.com

REMINDER: Keep your dated proof of purchase for warranty purposes! 

Attach it to this manual or file it for safekeeping.

IN634800AV 8/10

See Warranty on page 8 for important information about commercial use of this product.

operating Instructions  

HX5100, HX5101

© 2010 Campbell Hausfeld/Scott Fetzer

oil-lubricated 

Compressors

Description

This oil-lubricated compressor is 
designed for do-it-yourselfers with a 
variety of home and automotive jobs. 
These compressors can power spray 
guns, impact wrenches and other tools. 
Compressed air from this unit will 
contain moisture. Install a water filter 
or air dryer if application requires dry 
air.

Safety Guidelines

This manual contains information 
that is very important to know and 
understand. This information is 
provided for SAFETY and to PREVENT 
EQUIPMENT PROBLEMS. To help 
recognize this information, observe the 
following symbols.

 

Danger indicates an  

  imminently 

hazardous situation which, if not 
avoided, WILL result in death or serious 
injury.
 

Warning indicates a  

  potentially 

hazardous situation which, if not 
avoided, COULD result in death or 
serious injury.
 

Caution indicates a  

  potentially 

hazardous situation which, if not 
avoided, MAY result in minor or 
moderate injury.
 

Notice indicates  

  important 

information, that if not followed, may 
cause damage to equipment.

Unpacking

After unpacking the unit, inspect 
carefully for any damage that may 
have occurred during transit. Make sure 
to tighten fittings, bolts, etc., before 
putting unit into service. In case of 
questions, damaged or missing parts, 

GEnEral InforMatIon

 

Do not operate unit 

  if damaged during 

shipping, handling or use. Damage may 
result in bursting and cause injury or 
property damage. 
 

Do not run 

  unattended. 

Leaving compressor in AUTO position 
may allow it to turn on inadvertently. 
To prevent this and possible damage 
from power surge, turn to OFF position 
after each use.

Record the Model No., Serial No. and date 
of purchase located on the base below the 
pump in the space below.
Model No. 

______________________

Serial No. 

______________________

Date of purchase   ______________________
Retain these numbers for future reference.

Do not rEtUrn tHE
proDUCt to tHE
rEtaIlEr!

STOP!

Breathable Air Warning

this compressor/pump is not 

equipped and should not be 

used “as is” to supply breathing 

quality air. for any application of 

air for human consumption, the 

air compressor/pump will need 

to be fitted with suitable in-line 

safety and alarm equipment. 

this additional equipment is 

necessary to properly filter 

and purify the air to meet 

minimal specifications for Grade 

D breathing as described in 

Compressed Gas association 

Commodity Specification G 

7.1 - 1966, oSHa 29 Cfr 1910. 

134, and/or Canadian Standards 

associations (CSa).

DISClaIMEr of WarrantIES
In the event the compressor 

is used for the purpose of 

breathing air application 

and proper in-line safety 

and alarm equipment is not 

simultaneously used, existing 

warranties shall be voided, and 

the manufacturer disclaims any 

liability whatsoever for any loss, 

personal injury or damage.

Summary of Contents for HX5100

Page 1: ...azardous situation which if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Caution...

Page 2: ...and electrical components for signs of damage deterioration weakness or leakage Repair or replace defective items before using 8 Check all fasteners at frequent intervals for proper tightness Motors e...

Page 3: ...sk of electrical shock by providing an escape wire for electric current This product is equipped with a cord having a grounding wire with an appropriate grounding plug Plug must be plugged into an out...

Page 4: ...flow 2 Connect air hose to outlet of regulator 3 Turn on off switch to OFF position 4 Plug in power cord 5 Turn on off switch to AUTO position and let compressor run until it reaches automatic shutof...

Page 5: ...CHANGE 1 Allow compressor to run and warm up oil Unplug unit 2 Position a pan under pump end of unit 3 Remove oil drain plug see Figure 6 Allow oil to collect in pan Tilt unit to completely drain 4 R...

Page 6: ...tch 5 Defective motor capacitor 6 Motor shorted or seized 1 Check for proper fuse Use time delay fuse Disconnect other electrical appliances from circuit or operate compressor on its own branch circui...

Page 7: ...ston and cylinder Excessive moisture in discharge air 1 Excessive water in tank 2 High humidity 1 Drain tank 2 Move to area of less humidity use air line filter Note Water condensation is not caused b...

Page 8: ...arranty 1 All Compressors a Any component damaged in shipment or any failure caused by installing or operating unit under conditions not in accordance with installation and operation guidelines or dam...

Page 9: ...ar Informa es gerais N o coloque a unidade em funcionamento caso tenha sido danificada durante o transporte manuseio ou uso O dano pode resultar em ruptura e causar avaria ou dano da estrutura N o dei...

Page 10: ...te para as m os 7 Antes de cada utiliza o inspecione o sistema de ar comrpimido e os componentes el tricos para verificar sinais de dano deteriora o debilidade ou perdas Conserte ou substitua os itens...

Page 11: ...el trico por oferecer um cabo el trico para desvio da corrente Este produto est equipado com um cabo contendo um fio de aterramento com seu respectivo conector apropriado Este fio dever ser conectado...

Page 12: ...abra a v lvula de drenagem O compressor est pronto para o uso Procedimento operacional antes de cada partida 1 Gire o bot o do regulador completamente no sentido anti hor rio para a esquerda para fech...

Page 13: ...inferior D batidas no tanque para certificar se de que toda umidade foi removida 3 Remova a poeira e a sujeira do tanque linhas de ar e cobertura da bomba enquanto o compressor estiver desligado Troca...

Page 14: ...to circuito sobrecarregado 2 Fio de espessura errada ou comprimento de cabo de extens o errado 3 V lvula de reten o com defeito 4 V lvula de descarga com defeito no pressostato 5 Condensador do motor...

Page 15: ...um vazamento for detectado o tanque deve ser substitu do por uma pe a de reposi o original 5 Substitua as v lvulas do compressor conforme necess rio 6 Recoloque o pist o e o cilindro Umidade excessiva...

Page 16: ...u opera o da unidade sob condi es que n o estejam em conformidade com as diretrizes de instala o e opera o ou danificados devido a contatos com ferramentas ou arredores b Falha da bomba ou v lvula cau...

Page 17: ...ejo o uso Los da os podr an ocasionar una explosi n y casionarle heridas o da os a su propiedad No lo haga funcionar sin supervisi n El dejar el compresor en la posici n AUTO puede causar que se encie...

Page 18: ...o 8 Chequ e todas las conexiones frecuentemente para cerciorarse de que est n bien apretadas Los motores equipos el ctricos y controles pueden ocasionar arcos el ctricos que encender an gases o vapore...

Page 19: ...ar a el riesgo de choque el ctrico al ofrecerle un cable de desv o a la corriente el ctrica Este producto tiene un cord n con un alambre y terminal de conexi n a tierra Debe conectarlo a un tomacorrie...

Page 20: ...del regulador totalmente hacia la izquierda 2 Conecte la manguera de aire a la salida del regulador 3 Coloque el interruptor de encendido apagado en la posici n OFF apagado 4 Enchufe el cable de corri...

Page 21: ...s de aire y la cubierta de la bomba mientras el compresor contin a apagado OFF cambios de aceite 1 Encienda el compresor de modo que el aceite se caliente Desenchufe la unidad 2 Coloque un recipiente...

Page 22: ...correcto circuito sobrecargado 2 Calibre del cable o largo del cord n de extensi n incorrectos 3 V lvula de retenci n defectuosa 4 V lvula de descarga defectuosa en el interruptor de presi n 5 Condens...

Page 23: ...Si detecta una fuga se deber reemplazar el tanque con una pieza de repuesto original 5 Reemplace las v lvulas del compresor seg n sea necesario 6 Reemplace el pist n y el cilindro Exceso de humedad e...

Page 24: ...ado por haber instalado u operado la unidad bajo condiciones contrarias a lo indicado en las instrucciones para instalar u operar la unidad o da os ocasionados por el contacto con herramientas o los a...

Reviews: