background image

1. Read all manuals included

with this product carefully.
Be thoroughly familiar
with the controls and the
proper use of the equipment.

2. Follow all local electrical and safety

codes as well as in the US, National
Electrical Codes (NEC) and Occupational
Safety and Health Act (OSHA).

Do not operate
unit if damaged

during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.

General Safety
Information

CALIFORNIA PROPOSITION 65

This product
or its power cord

may contain chemicals known to the
State of California to cause cancer and
birth defects or other reproductive
harm. Wash hands after handling.

GENERAL SAFETY INFORMATION

Since the air compressor and other
components used (filters, lubricators,
hoses, etc.), make up a high pressure
pumping system, the following safety
precautions must be observed at all times:

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

Description

Oilless compressors are designed for
do-it-yourselfers with a variety of home
and automotive jobs. These units
operate without oil. Compressed air
from this unit will contain moisture.
Install a water filter or air dryer if
application requires dry air.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols. 

Danger indicates an
imminently

hazardous situation which, if not avoided,
will result in death or serious injury.

Warning indicates 
a potentially

hazardous situation which, if not
avoided, COULD result in death or
serious injury.

Caution indicates a
potentially

hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.

Notice indicates
important

information, that if not followed, may
cause damage to equipment.

Unpacking

After unpacking the unit, inspect
carefully for any damage that may have
occurred during transit. Make sure to
tighten fittings, bolts, etc., before putting
unit into service. In case of questions,
damaged or missing parts, please call 1-
800-543-6400 for customer assistance.

Have the date code, model number,
and parts list (with missing parts
circled) before calling.

Operating Instructions and Parts Manual

FP209800

L

IN626700AV  7/08

Breathable Air Warning

This compressor/pump is not
equipped and should not be used
“as is” to supply breathing quality
air. For any application of air for
human consumption, the air
compressor/pump will need to be
fitted with suitable in-line safety
and alarm equipment. This
additional equipment is necessary
to properly filter and purify the air
to meet minimal specifications for
Grade D breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).

DISCLAIMER OF WARRANTIES
In the event the compressor is used
for the purpose of breathing air
application and proper in-line
safety and alarm equipment is not
simultaneously used, existing
warranties shall be voided, and
Campbell Hausfeld disclaims any
liability whatsoever for any loss,
personal injury or damage.

STOP!

Record the Model No., Serial No. and
date of purchase located on the base
below the pump in the space below.

Model No. ____________________

Date Code ____________________

Date of purchase _________________

Retain these numbers for future
reference

.

Oilless Compressors

DO NOT RETURN THE
PRODUCT TO THE
RETAILER! CALL 
1-800-543-6400

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

See Warranty on page 8 for important information about commercial use of this product.

© 2008 Campbell Hausfeld/Scott Fetzer

For parts, product & service information

visit 

www.chpower.com

MANUAL

Summary of Contents for Oilless Compressors FP209002L

Page 1: ...icates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury Notice indicates important information that if not followed may cause damage to equipment Unpacking After unpacking the unit inspect carefully for any damage that may have occurred during transit Make sure to tighten fittings bolts etc before putting unit into service In case of questions damaged o...

Page 2: ...sture or depressurizing the compressor system 15 Indoor use only 16 To reduce the risk of electrical shock do not expose to rain Store indoors SPRAYING PRECAUTIONS Do not spray flammable materials in vicinity of open flame or near ignition sources including the compressor unit 17 Do not smoke when spraying paint insecticides or other flammable substances 18 Use a face mask respirator when spraying...

Page 3: ...flow of air completely Pressure Gauges There are two gauges located next to the regulator These gauges read air pressure in pounds per square inch psi The larger gauge shows pressure at the outlet Make sure this gauge reads ZERO by adjusting the regulator BEFORE changing air tools or disconnecting hose from outlet The small gauge shows pressure in the tank indicating compressor is building pressur...

Page 4: ...pe compressor requiring no lubrication THERMAL OVERLOAD PROTECTOR This com pressor is equipped with an automatic reset thermal overload protector which will shut off motor if it becomes overheated If thermal overload protector shuts motor OFF frequently look for the following causes 1 Low voltage 2 Lack of proper ventilation If the thermal overload protector is actuated the motor must be allowed t...

Page 5: ...5 FP209800 www chpower com Notes ...

Page 6: ...ted area where temperature will not exceed 100 F 5 Check all electrical connections 6 Replace ON OFF switch 7 Replace pressure switch 8 Replace pump motor assembly 1 Move compressor to a clean well ventilated area where temperature will not exceed 100 F 2 Decrease usage or purchase unit with higher air delivery SCFM 1 Close tank drain valve 2 Check all connections with soap and water solution If a...

Page 7: ...5102AV 1 9 Motor isolator 2 10 Pressure switch FP209530AV 1 11 Check valve FP209532AV 1 12 Power cord FP209534AV 1 12a Ground screw 1 12b Strain relief 1 13 Housing screw 4 14 Nut 4 15 Drain valve D 1403 1 16 Rubber foot 4 17 Foot bolt 4 18 Wire pressure switch to power switch FP209523AV 1 19 Pump motor assembly FP209039AV 1 19a Exhaust tube assembly FP202839AV 1 20 Wire clip FP202823AV 1 21 Screw...

Page 8: ...tc F Gasoline engines and components are expressly excluded from coverage under this limited warranty The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product G Additional items not covered under this warranty 1 All Compressors a Any component damaged in shipment or any failure caused by installing or operating unit under conditions not in acc...

Page 9: ...eiller à serrer tout raccord boulon etc avant de mettre ce produit en service En cas de dommage ou de parties manquantes S V P composer le 1 800 543 6400 pour demander conseil Prière d avoir le numéro de série numéro de modèle et liste de parties avec les parties manquantes encerclées avant d appeler S il vous plaît lire et conserver ces instructions Lire attentivement avant de monter installer ut...

Page 10: ...ut être dangereux Lâcher l air lentement en purgeant l humidité ou pendant la dépressurisation du système du compresseur 15 Utilisation d intérieur seulement 16 Pour réduire le risque de choc électrique ne pas exposer à la pluie Ranger à l intérieur PRÉCAUTIONS DE PULVÉRISATION Ne pas pulvériser les matériaux inflammables dans un endroit de flamme ouverte ni près d une source d ignition y compris ...

Page 11: ... du régulateur se tourne dans le sens horaire à droite pour augmenter la pression d air à la sortie Le bouton du régulateur se tourne dans le sens antihoraire à gauche pour réduire la pression d aire à la sortie Pour couper le débit d air tourner le bouton complètement dans le sens antihoraire Manomètre s Il y a deux types de manomètres près du régulateur Ces manomètres indiquent la pression d air...

Page 12: ... pas sortir l air en tirant sur l anneau ou si elle ne se ferme pas automatiquement il FAUT la remplacer PURGER LE RÉSERVOIR Avec le compresseur hors circuit et la pression dissipée purger l humidité du réservoir en ouvrant le robinet de purge sous le réservoir NETTOYAGE Mettre hors circuit OFF et nettoyer la poussière et la saleté du couvercle de la pompe du réservoir et des canalisations d air I...

Page 13: ...isage 4 Vidanger le réservoir de toute condensation en ouvrant le robinet de vidange au fond du réservoir La pression du réservoir doit être sous 69 kPa quand on vidange le réservoir 5 Le tuyau doit être débranché du compresseur et suspendu avec les bouts ouverts face en bas pour laisser couler toute humidité 6 Le compresseur et le tuyau doivent être rangés dans un endroit frais et sec Notes Entre...

Page 14: ...asse pas 38 C 100 F 5 Vérifier toutes les connexions électriques 6 Remplacer l interrupteur ON OFF 7 Remplacer le pressostat 8 Remplacer le montage de pompe moteur 1 Déplacer le compresseur dans un endroit propre bien ventilé où la température ne dépasse pas 38 C 100 F 2 Réduire l utilisation ou acheter un appareil plus puissant SCFM 1 Fermer le robinet de vidange du réservoir 2 Vérifier toutes le...

Page 15: ... de pied 4 18 Fil pressostat avec interrupteur FP209523AV 1 19 Montage de pompe moteur FP209039AV 1 19a Trousse de tuyau de ventilation FP202839AV 1 20 Atache de fils FP202823AV 1 21 Vis 1 22 Couvercle de moteur 1 23 Accessoires FP204008AV 1 24 Tuyau de rappel de 7 62 m 25 pi MP268100AV 1 25 Base de plastique 1 26 Trousse de tuyau de manostat FP209535AV 1 27 Réservoir 1 28 Capuchon de plastique 4 ...

Page 16: ...acheteur doit observer la garantie du fabricant de moteur qui est fournie avec le produit G Articles supplémentaires qui ne sont pas couverts sous cette garantie 1 Pour tous les Compresseurs a Toutes pièces détachées endommagées pendant l expédition n importe quelle panne causée par un montage ou fonctionnement du modèle sous des conditions qui ne conforment pas aux directives de montage et de fon...

Page 17: ...para verificar si se han producido daños durante el transporte Asegúrese de apretar todos los accesorios pernos etc que estén sueltos antes de poner la unidad en servicio En el caso de que haya daño o partes que faltan haga el favor de llamar al 1 800 543 8622 para obtener ayuda Tenga a mano el número de serie el número del modelo y la lista de partes con las partes que faltan marcadas con un círc...

Page 18: ...nque o liberar la presión del sistema 15 Uso de interior solamente 16 Para reducir el riesgo de choque eléctrico no exponer a la lluvia Guarde bajo techo PRECAUCIONES PARA ROCIAR Nunca rocíe materiales inflamables cerca de llamas al descubierto o fuentes de ignición incluyendo el compresor 17 No fume mientras esté rociando pintura insecticidas u otras substancias inflamables 18 Use una máscara res...

Page 19: ...la izquierda la presión de aire a la salida disminuye Al girar la perilla completamente en sentido antihorario el suministro de aire se cierra completamente Manómetros Hay dos tipos de manómetros ubicados cerca del regulador Estos manómetros indican la presión de aire en libras por pulgada cuadrada bar El manómetro más grande indica la presión a la salida Asegúrese de que este manómetro indique CE...

Page 20: ...A APAGUE la unidad y limpie la tapa del cabezal el tanque y las líneas de aire IMPORTANTE El compresor debe colocarse lo más lejos posible del área de pulverización según lo permita la longitud de la manguera para evitar que el exceso de pulverización atasque el filtro de aire LUBRICACION Este compresor no requiere lubricación PROTECTOR TERMICO Este compresor está equipado con un protector automát...

Page 21: ...21 Sp FP209800 Notas ...

Page 22: ...peratura no exceda los 100ºF 5 Verifique todas las conexiones eléctricas 6 Reemplace el interruptor ON OFF 7 Cambie el interruptor de presión 8 Reemplace el ensamble de la bomba motor 1 Mueva el compresor a un área limpia y bien ventilada donde la temperatura no exceda los 100ºF 2 Disminuya el uso o compre una unidad que ofrezca una entrega de aire mayor SCFM 1 Cierre la válvula de drenaje del tan...

Page 23: ...enaje D 1403 1 16 Patas de caucho 4 17 Perno de pata 4 18 Cable interruptor de presión a interruptor de corriente FP209523AV 1 19 Ensamblaje de bomba motor FP209039AV 1 19a Tubo de escape FP202839AV 1 20 Sujetador del cable FP202823AV 1 21 Tornillo 1 22 Cubierta del motor 1 23 Accesorios FP204008AV 1 24 Manguera de retroceso de 7 62 m MP268100AV 1 25 Base plástica 1 26 Juego de tubo del Presostato...

Page 24: ...eguir las cláusulas de la garantía otorgada por el fabricante del motor de gasolina que se suministra con el producto G Artículos adicionales no cubiertos bajo esta garantía 1 Para todos los Compresores a Cualquier componente dañado durante el envío o cualquier daño ocasionado por haber instalado u operado la unidad bajo condiciones contrarias a lo indicado en las instrucciones para instalar u ope...

Reviews: