Summary of Contents for ME10

Page 1: ...Electric Mini Tank Water Heaters USE CARE MANUAL Series Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475...

Page 2: ...ure Pressure Relief Valve Filling the Water Heater Electrical Connections Instructions for Use Maintenance Instructions Troubleshooting Warranty Schematic Disassembly Parts List 2 3 4 5 6 6 6 7 7 8 9...

Page 3: ...close supervision is necessary when used by children 7 Do not operate this water heater if it has a damaged cord or plug if it is not working properly or if it has been damaged or dropped 8 This wate...

Page 4: ...150 12 1 12 1 2 5 120 1440 150 14 4 12 1 4 0 120 1440 150 18 2 12 1 6 0 120 1440 150 25 4 12 1 Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475 Indicator...

Page 5: ...0 3 8 15 1 2 Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475 Schematic construction Wiring diagram Dimensions A B C K L G E N T R V Grounding Wire Elemen...

Page 6: ...et CAUTION The thermostats on this water heater have been set at the factory to 125 F 52 C or lower to reduce the risk of scald injury Locate the front panel and temperature adjustment knob on the wat...

Page 7: ...Description There are 4 Camplux Mini Tank models with 1 3 2 5 4 0 and 6 0 gallon capacity The pressure vessel water tank is welded glass lined steel and is equipped with an anode rod The water heater...

Page 8: ...inlet pipe to the inlet nipple marked with a blue ring and the hot water outlet pipe to the outlet nipple marked with a red ring IMPORTANT If water pipes are copper or bronze use dielectric connectio...

Page 9: ...is purpose in the water heater and Orient it or provide tubing so that any discharge from the valve exits only within 6 inches above or at any distance below the structural foor and does not contact a...

Page 10: ...Install a 125 psi pressure relief valve in the cold water supply line Make sure the discharge Of this valve is directed to an open drain and protected from freezing Contact your local water Utility o...

Page 11: ...errupt the power supply in the event of a thermostat failure This water heater is designed for only 120V electrical service Do not connect to any other voltage Failure to use proper voltage may result...

Page 12: ...the snowflake position to guard against freezing This position will keep the internal water temperature above the freezing point See the photo below Maintenance Instructions Do not attempt to repair...

Page 13: ...o drain remaining water out of the heater Removing the heating element 1 Unplug water heater power cord and drain see above 2 Remove cover 3 Remove all the line wires from the heating element 4 Unscre...

Page 14: ...nplug water heater power cord from the electrical outlet 2 Drain and remove the water heater see page 12 3 Remove six screws retaining the bottom panel of the water heater and remove the panel 4 Remov...

Page 15: ...not tamper with the reset button to override overheating shut down 1 Unplug water heater power cord from the electrical outlet 2 Drain and remove the water heater see page 12 3 Remove six screws retai...

Page 16: ...here is no crossover then replace the heating element see page 13 Problem Indicator light not on 1 If the light does not come on but water gets hot check for faulty bulb 2 Check reset button follow st...

Page 17: ...ble water Camplux will furnish the Owner with a replacement of the defective part s 3 Verification of Date Original Installation When the owner can not verify or document the original date of installa...

Page 18: ...ualified personnel 5 The owner and not the manufacturer or his agent representative shall be liable for and shall pay for all field charges for labor or other expenses incurred in the removal and or r...

Page 19: ...service request is made be sure to include Proof of Purchase the water heater model number and the date of manufacture date of installation dealer s name and the watts and voltage 4 When returning the...

Page 20: ...sket Temp Control Knob Red Circle QTY 1 1 1 1 6 1 1 1 1 2 2 1 1 1 1 1 1 Name of Part Front Cover Back Cover Power Cord Screw Blue Circle Power Cord Sheath Power Cord Sheath Press Cross Screw Connect P...

Page 21: ...www camplux com 20 Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475...

Page 22: ...Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475...

Page 23: ...Chauffe eau lectrique Mini R servoir MANUEL D UTILISATION ET D ENTRETIEN Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475 Series...

Page 24: ...844 538 7475 Consignes de s curit importantes Donn es techniques Informations g n rales Description technique Instructions pour l installation Connexion de tuyauterie Soupape de d charge de pression...

Page 25: ...eptacle n est disponible c t du chauffe eau contactez un lectricien qualifi pour en faire installer un correctement 6 Comme pour tout appareil une surveillance troite est n cessaire lorsqu il est util...

Page 26: ...IT TRE COMPL TEMENT PLEIN D EAU ET AVOIR DE L EAU QUI S COULE DU ROBINET D EAU CHAUDE AVANT D ACTIVER L ALIMENTATION AU CHAUFFAGE POUR LA PREMI RE FOIS SINON DES DOMMAGES SERONT OCCASIONN S Donn es te...

Page 27: ...0 3 8 10 3 8 15 1 2 Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475 A B C Fiche d alimentation lectrique Sortie d eau Soupape de limitation de pression A...

Page 28: ...protection Overheating Thermostat Voyant lumineux l ment chauffant Fiche d alimentation lectrique Informations g n rales Les chauffe eaux mini r servoir Camplux peuvent tre utilis s dans la plupart de...

Page 29: ...N Camplux n est pas responsable des dommages caus s par une installation inad quate ou par le non respect des instructions de ce manuel Veuillez suivre les instructions du manuel d installation avant...

Page 30: ...il est ouvert AVERTISSEMENT L installateur doit revoir le contenu de ce manuel avec le propri taire la fin de l installation Le manuel doit rester avec le propri taire et tre plac dans un endroit pro...

Page 31: ...urni au mur Utilisez des vis adapt es au mat riau du mur et au poids du chauffe eau rempli sa capacit ME10 24 lbs ME25 41 lbs ME40 57 lbs ME60 76 lbs Accrochez le chauffe eau au support et tirez le ch...

Page 32: ...raccord union filet avant de visser le raccord au r servoir N appliquez pas de chaleur directement sur les connexions d entr e ou de sortie Soupape de d charge de pression et de temp rature ATTENTION...

Page 33: ...ou une d faillance du joint de l l ment peut tre en raison de la dilatation thermique dans un syst me d alimentation en eau ferm Le compteur d alimentation d eau contient un clapet anti retour un dis...

Page 34: ...avec de l eau et que tout l air est limin Avant de brancher l alimentation remplissez le r servoir et le syst me d eau avec de l eau et v rifiez s il y a des fuites Pour vous assurer que tout l air e...

Page 35: ...er une autre tension Le non respect de la tension appropri e peut entra ner des blessures corporelles et ou des dommages mat riels Si le c ble d alimentation lectrique fourni est endommag ou n est pas...

Page 36: ...e position maintiendra la temp rature de l eau au dessus du point de cong lation Consignes d entretien N essayez pas de r parer le chauffe eau vous m me Appelez un technicien plombier ou lectricien po...

Page 37: ...auffant 4 D vissez les crous de retenue de l l ment chauffant 5 Retirez l l ment D tartrage de l l ment chauffant Les d p ts de tartre peuvent affecter la capacit de chauffage de l l ment Le tartre lo...

Page 38: ...ire de soulever le bouton de l axe du thermostat Retirez maintenant le panneau avant 5 D branchez les connecteurs de fils push pull sur le thermostat en notant quel connecteur va quelle borne Les born...

Page 39: ...fonctionne 2 Si la lumi re ne s allume pas v rifiez que le bouton de r initialisation est enfonc suivre les tapes de la section pr c dente 3 Si le voyant lumineux est allum mais que la temp rature de...

Page 40: ...auffe eau au Propri taire ci apr s Propri taire du chauffe eau l emplacement d origine de l installation contre les d fauts de mat riaux et de fabrication pendant les p riodes sp cifi es ci dessous P...

Page 41: ...rales y compris mais sans s y limiter les garanties ou la qualit marchande et l ad quation un usage particulier 2 Camplux ne sera pas responsable des dommages ou d penses accessoires cons cutifs sp ci...

Page 42: ...chauffe eau Camplux doit tre install de telle mani re qu en cas de fuite le d bit d eau qui en r sulte n endommage pas la zone dans laquelle il est install Comment le propri taire peut il obtenir une...

Page 43: ...nexion int rieur Vis crois e Couverture int rieure Couvercle de bouton Couvercle de indique la lumi re La puissance indique la lumi re Soutien 1 Soutien 2 Plaque de presse fil l ment chauffant Limite...

Page 44: ...Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475...