background image

 

 

M O D E L  

M 2 1 8  

 

( F O R M E R L Y    
H P   E 2 2 7 0 A

)

 

U S E R

’ S   M A N U A L  

1 6 - C H A N N E L    

F O R M   A   S W I T C H    

M - M O D U L E    

 

 

Document Part No: 11029534 

C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, Texas  78681 <> www.chtech.com

Summary of Contents for M218

Page 1: ...F O R M E R L Y H P E 2 2 7 0 A U S E R S M A N U A L 1 6 C H A N N E L F O R M A S W I T C H M M O D U L E Document Part No 11029534 C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78...

Page 2: ...Hewlett Packard Agilent User Manual s with their expressed written permission The information and or drawings set forth in this document and all rights in and to inventions disclosed herein which mig...

Page 3: ...mendments to the manual If any amendments are provided for this manual they are printed on colored paper and will be provided with the module and manual Manual updates may also be found on out web sit...

Page 4: ...available in many formats such as Ethernet VME VXI PXI cPCI and the PC Contained within this manual are the physical and electrical specifications installation and startup procedures functional descri...

Page 5: ...4 PREPARATION FOR RESHIPMENT 6 3 0 FUNCTIONAL DESCRIPTION 7 3 1 OVERVIEW 7 3 1 1 M Module Interface 7 3 1 2 Module Control 7 3 1 3 ID EEPROM 8 3 1 4 Row and Column Drivers 8 3 1 5 Driver Power Switch...

Page 6: ...Schematic 9 Figure 4 M218 I O Registers 11 Figure A 1 Front Panel I O Signals A 1 LIST OF TABLES Table I Specifications 2 Table II I O Address Map Command Summary 10 Table III M MA Module PROM IDENT W...

Page 7: ...dule uses latching relays that retain their last programmed state whenever power is removed closed relays will remain closed until opened via your test program CAUTION This module DOES NOT have provis...

Page 8: ...VDC VACrms VAC peak Current non inductive Per Switch DC Per Switch AC Per Module DC Per Module AC 2 2 8 8 A A peak A A peak Power Per Switch DC Per Switch AC Per Module DC Per Module AC 50 50 200 200...

Page 9: ...A not supported Triggers not supported Identification IDENT Manufacturer ID 0FFF16 See note below Model Number 068616 VXI Model Number 025B16 Note C H obtained the manufacturing rights from Hewlett Pa...

Page 10: ...4 C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com...

Page 11: ...static controlled workstation whenever possible At a minimum avoid work areas that are potential static sources such as carpeted areas Avoid unnecessary contact with the components on the module 2 3 I...

Page 12: ...ling the bag keep trapped air volume to a minimum The shipping container should be a rigid box of sufficient size and strength to protect the equipment from damage If the module was received separatel...

Page 13: ...ntrol VCC DGND RST ROM ID EEPROM Figure 2 M218 Functional Block Diagram 3 1 1 M Module Interface The M Module Interface allows communication between the M218 and the carrier module The interface is an...

Page 14: ...and lines from Module Control into the bipolar buffered drive signals COL_DR 4 1 The COL_DR 4 1 signals provide either current source from the 5VDR supply relay reset or current sink to ground relay s...

Page 15: ...7_COM 31 42 Channel 8 Channel 9 Channel 10 Channel 11 9 CH8_NO 24 CH8_COM 10 CH9_NO 25 CH9_COM 11 CH10_NO 26 CH10_COM 12 CH11_NO 27 CH11_COM Channel 12 Channel 13 Channel 14 Channel 15 13 CH12_NO 28 C...

Page 16: ...ter Type FIFO able Register Y N 00h Status Register Read Only N 02h Control Register Read Write N 04h 0Eh Reserved NA N 10h Row 0 Set Register Read Write Y 12h Row 0 Reset Register Read Write Y 14h Ro...

Page 17: ...0 Write Reserved TM DPE STE INTE RST Read Reserved TM Timer Mode proper operation is guaranteed only for the time 8ms 0 0 8ms 0 1 2ms 1 0 4ms 1 1 64ms DPE Driver Power Enable 1 enables power to relay...

Page 18: ...R2C0 Reg 1C Row 3 Set Register Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Write Unused R3C3 R3C2 R3C1 R3C0 Read Unused R3C3 R3C2 R3C1 R3C0 Reg 1E Row 1 Reset Register Bit 15 14 13 12 11 10 9 8 7 6 5 4...

Page 19: ...odule Characteristics 2 0868 4 7 Reserved 0000 8 15 M Module Specific 0000 16 VXI Sync Code ACBA 17 VXI ID 0FFF 3 18 VXI Device Type 3 F25B M218 19 31 Reserved 0000 32 63 M Module Specific 0000 Notes...

Page 20: ...FIFO see note below then the module asserts an interrupt only after the completion of the fourth operation Note The module asserts an interrupt after the relay drive time is complete relay drive time...

Page 21: ...initialized 1 To guarantee break before make relay operation write to the Row n Reset registers before writing to the Row n Set registers 2 It is important to use the FIFO status bits when writing to...

Page 22: ...s an interrupt only after the completion of the fourth operation Note The module asserts an interrupt after the relay drive time is complete relay drive timer and no other operations have been stored...

Page 23: ...hat may be applied to the M218 M219 or M220 is Per Switch 2 ADC 2 AAC peak Per Module 8 ADC 8 AAC peak Pin Use Pin Use Pin Use 1 CH0_NO 16 CH0_COM 31 Chassis 2 CH1_NO 17 CH1_COM 32 Chassis 3 CH2_NO 18...

Page 24: ...A 2 C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com...

Page 25: ...N O T E S C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com...

Page 26: ...C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com...

Page 27: ...oever You may of course continue to use the information which you supply Please refrain from using this form for technical questions or for requests for additional publications this will only delay th...

Page 28: ...r or not your comments were being incorporated NOTE This form may not be used to request copies of documents or to request waivers deviations or clarification of specification requirements on current...