C&J DGT5000 

Suite ‘Shelf’ or ‘Slab’ Burner 

 

Owner's Book 

(THIS APPLIANCE IS FITTED WITH ALKALINE BATTERIES) 

 

INCLUDES USER, INSTALLATION & MAINTENANCE 

INSTRUCTIONS

 

 
 
 
 

Please read these instructions carefully before you start using the 

appliance 

 
 

Keep this booklet handy for future reference 

 
 

This appliance is 

for use in GREAT BRITAI or IRELAD only 

 

A QUALITY PRODUCT FROM C&J FIRES

 

 
 

Summary of Contents for DGT 5000

Page 1: ...LKALINE BATTERIES INCLUDES USER INSTALLATION MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This ap...

Page 2: ...ce opening dimensions 14 Hole in the Wall installations 14 Clearance to Shelf 15 Clearance to Side of Fire 15 Ventilation 15 SECTION NINE To Install the Appliance 16 Examine Flue Chimney 16 Preparing...

Page 3: ...To keep dust to a minimum these materials should be securely wrapped in polythene and be clearly labelled RCF waste These materials are not classified as hazardous waste and should be disposed of at a...

Page 4: ...rging if rechargeable batteries have been used Important Batteries should be changed or recharged as soon as possible as the appliance will not light if the battery power gets to low The appliance inc...

Page 5: ...Before cleaning ensure that the appliance is turned off and cold In some instances you may experience ignition problems even when the appliance is new This may be due to the aeration hole in the pilo...

Page 6: ...liance will automatically go to the maximum or minimum settings On the other hand if the button is not released gradual adjustment is made until the button is released or until the maximum or minimum...

Page 7: ...as appropriate WARNING batteries will overheat if fitted incorrectly when fitting the batteries ensure that they are fitted as per the marking on the rear of the holder i e minus of battery against s...

Page 8: ...the pilot head clear of granules to ensure good cross lighting FUEL BED LAYOUT COAL OPTION One or two packs of 17 coals can be used to enhance the fuel bed on the DGT 5000 burners The first pack of co...

Page 9: ...of 17 coals can be obtained to lay around the burner unit grille as shown Leave plenty of air gaps between the coals to ensure that the cooling air flow to the underside of the burner is not impeded...

Page 10: ...les on top of the burner area of the fire FUEL BED LAYOUT EXTRA PEBBLE OPTION An extra pack of 17 pebbles can be obtained to lay around the burner unit grille as shown Leave plenty of air gaps between...

Page 11: ...Regulations 1998 as amended The chimney or flue should be checked annually to ensure clearance of combustion products Ventilation in the United Kingdom This appliance does not normally require purpose...

Page 12: ...n optional extra together with a dedicated rechargeable system Data Label Location Behind trim Gas Connection 8 mm OD Tube SECTION SIX Regulations and Warnings THIS APPLIANCE MUST ONLY BE INSTALLED IN...

Page 13: ...re a small fireplace opening together with a larger diameter flue to give the limited flue height sufficient draw to clear the products of combustion successfully A smooth gather into the flue liner o...

Page 14: ...ing an internal canopy to the fireplace can be one option to reduce the frontal opening area and to improve the spillage Ventilation must also be checked to ensure it is adequate for products of combu...

Page 15: ...erial shelf mounted in position temporarily and check the temperature rise does not exceed 80 degrees C above the ambient room temperature at any time in up to six hours of burning N B A minimum clear...

Page 16: ...Remove the battery compartment by lifting it out of the firebox Remove the top grille from the fire by removing the 4 securing screws Remove the burner unit by lifting it out right hand side first Re...

Page 17: ...as supply The flue is also accessible from above the appliance Therefore the simplest way to discretely secure the firebox is to fix it in position using silicone adhesive sealant or similar under the...

Page 18: ...d with the fan running If there is a connected room with an extractor fan the test should be repeated with all the doors to that room opened and the extractor fan running COMPLETION OF INSTALLATION De...

Page 19: ...terial The loose fuel bed components are delicate and they should be handled with great care They may be removed for cleaning They can be brushed very gently with a soft brush to remove dust or any de...

Page 20: ...ion from the electronic control box 4 Remove ignition lead from pilot assembly 4 Remove the two screws securing the oxy pilot to the burner 5 Before replacing ensure the code number for Oxy Pilot repl...

Page 21: ...which is located on a swing tab under appliance Retailer Name ___________________________________________ Address ________________________________ ___________________________________________ ________...

Page 22: ...LT5032 01 05 08 22 Blank Page...

Page 23: ...4QJ YOUR DETAILS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model C J DGT 5000 Serial No Date of Purchase This information c...

Page 24: ...ire Box Labels Spillage Text Data Badge Burner Tray Box Assembly Warning Label Fire Guard Granules Set x 2 black white Vermiculite bag x 1 Restrictor Elbow and PTP Battery 9V PP3 Remote Control Hand S...