CanProx Proximity/Keypad 
Reader  

INSTALLATION INSTRUCTIONS 

 

 

 
 

 
 

 

 

 

 
 

 
 

 
 

 

July 2018 

Summary of Contents for P-620-HA

Page 1: ...CanProx Proximity Keypad Reader INSTALLATION INSTRUCTIONS July 2018...

Page 2: ...Party Controllers 7 Programming 8 P 640 HA P 620 HA 26 bit Wiegand Output 8 P 640 HA37 P 620 HA37 Cansec 37 bit Wiegand Output 8 Special Configuration Card For Cansec H1000 Controller 9 Proximity Key...

Page 3: ...0 HA37 8 bit burst default Cansec 37 bit Wiegand Frequency 125 KHz Range up to 7 varies with reader voltage and credentials Operating Temp 40 C to 65 C 40 F to 149 F Dimension HxWxD 117mm x 76mm x 19m...

Page 4: ...HA37 8 bit burst default Cansec 37 bit Wiegand Frequency 125 KHz Range up to 5 varies with reader voltage and credentials Operating Temp 40 C to 65 C 40 F to 149 F Dimension HxWxD 155mm x 45mm x 23mm...

Page 5: ...l for applications requiring an access credential and or personal identification number PIN NOTE Keypad data is transmitted in either Cansec 37 bit P 640 HA37 P 620 HA37 or standard 26 bit P 640 HA P...

Page 6: ...CanProx Proximity Keypad Reader Installation Instructions August 2018 Rev 1 6 Page 6 of 14 Wall Mounting...

Page 7: ...llers Trim off Ensure no contact to other wires Cansec Controller Important For illustration purposes only Pin placement is not in order as shown and does not match the layout of many Cansec controlle...

Page 8: ...4 Press the key reader will beep four times to indicate success 5 Press the key reader should beep four times to indicate 26 bit mode is enabled P 640 HA37 P 620 HA37 CANSEC 37 BIT WIEGAND OUTPUT APP...

Page 9: ...hen using the Keypad Options modes available in Hurricane software Card only Card plus PIN and PIN only or Card PIN Card PIN or Keypad Card ID options in First Access software See H1000 Integrated Key...

Page 10: ...neration utility are not required for MAP1 or MAP2 panels NOTE Must program keypad to output 8 bit Wiegand See Appendix for 8 bit burst mode The reader keypad alone does not provide the Card PIN featu...

Page 11: ...ode the mode can be changed to Card Only mode by opening the orange wire using a dry contact relay from an access control system a programmable timer key switch etc This allows for example the reader...

Page 12: ...which is algorithmically derived from the System Facility Code and ID number of the card they presented followed by key If the correct PIN is entered on the keypad the System Facility Code and ID data...

Page 13: ...reader in a different location or move any other electronic devices away from the reader 4 You are using an incorrect type of card Make sure you are using an access card that is compatible with the r...

Page 14: ...t burst mode However if it was programmed to output standard 26 bit Wiegand or Cansec 37 bit Wiegand then follow the steps below to enable 8 bit burst 1 Cycle power to the reader 2 Present the Wiegand...