background image

 

 

 

 

 

 

 

 

WA0239E_WSD12T-AV_User Manual_R02 

 

CAPETTI ELETTRONICA s.r.l.  -   Strada Stratta 57 
10090 CASTIGLIONE TORINESE  -  TORINO  -  ITALY 
VAT 04837130014 - Phone 011.981.98.11 -  Fax 011.981.98.210 
e-mail info@capetti.it  -  web www.capetti.it

 

 

 

1/8

 

 

WSD12T-AV 

User Manual 

1.

 

Description. 

The 

WSD12T-AV

 is a 

datalogger

 with 3 input channels to acquire outdoor temperature, voltage (

0÷10V

) and current (

4÷20mA

), with 

storage functionality of samples acquired.

 

 

 

 
 

2.

 

Datalogger preset and use mode.   

 

Wireless Mode: 

no  setup  operation  is  needed.  Typically  the  system  is  configured  from  factory  so  the 

datalogger

  is  already 

associated to the system 

basestation

. The 

datalogger

 is in 

STANDBY

 mode for which is necessary to start it with 

the 

TEST

 command (

refers to chapter 3 - Wireless Installation

). 

Otherwise, in case the 

datalogger

 is in 

FACTORY RESET

 mode, that means it's ready for connecting to an existing 

system, in order to associate it, make reference to the “

WineCapManager

” software manual. Is necessary to use 

the  "

WineCapManager

"  software  on  the  PC  connected  to  the 

basestation

  that  will  be  coupled  with  the 

datalogger

 

USB Datalogger Mode: 

for  this  operation  mode,  stand-alone  with  data  downloads  through  USB,  the  connection  with  the  PC  and  the 

WineCapManager

”  running  on  it  is  necessary  in  order  to  modify  the 

datalogger

's  operation  mode.  The 

sampling interval must be set with the 

datalogger

 in "

STAND-ALONE

" mode and automatically, the 

datalogger

's 

clock is aligned with the PC's clock, in order to assure the temporal reference of the sample. 

Sampling operations start may be selected disconnecting the USB cable or giving the proper command with the 
magnetic  key.  (

see  chapter  4  -  USB  Logger  Installation

).  More  details  on 

datalogger

's  connection/disconnection 

through the USB cable are available on the manual. 

 

On field transition from USB to Wireless datalogger: 

this  transition  is  practicable  in  field,  during  the  sampling  period,  using  the  wireless  network  association 
command. When the association is done, the 

datalogger

 becomes a wireless 

datalogger

 and, besides sending 

new  measures  to  the 

basestation

,  starts  a  download  process  towards  the  same 

basestation

  of  the  measures 

acquired during the stand alone period. 

Picture 1 - Product Image

 

Summary of Contents for WSD12T-AV

Page 1: ...on the PC connected to the basestation that will be coupled with the datalogger USB Datalogger Mode for this operation mode stand alone with data downloads through USB the connection with the PC and the WineCapManager running on it is necessary in order to modify the datalogger s operation mode The sampling interval must be set with the datalogger in STAND ALONE mode and automatically the datalogg...

Page 2: ...AV User Manual Picture 2 Datalogger positioning 3 Wireless dataloggers user interface The user interface consists of a virtual button that can be activated using the WineCapKey and of a two coloured led To give a command user must approach the WineCapKey to the datalogger s sensible area and keep it in that position the following picture Fig 3 shows datalogger s sensible points Picture 3 WineCapKe...

Page 3: ...ORY RESET The device performs the memory deleting procedure and goes in STOP status All samples configuration and wireless network data associated are LOST To reactivate the device a new association and configuration procedure is necessary ENROLL command Also in this case the FACTORY RESET command must be given twice to confirm it At the command execution the led flashes as the PROBE DATALOGGER NO...

Page 4: ...ts can help If the signal is absent or insufficient at the install point a WR12 router should be put between refer to WineCapManager User Manual The router itself must be located in a position where the signal level is at least sufficient The network will reconfigure itself automatically the signal will be good again when the datalogger synchronizes with the router The link will not be reconfigure...

Page 5: ...he datalogger If the device is shut off and left unused for a long time you can issue the STANDBY command Its corresponds to the command number 4 and must be issued twice to confirm the operation Position the WineCapKey in the spot indicated in Picture and wait for four AMBER flashes then remove the WineCapKey from datalogger Verify that the datalogger asks for confirmation of STANDBY command with...

Page 6: ...rehousing 40 C 70 C Radio frequency ISM 868MHz Radio coverage From 800m up to 12 8Km on sight Sealing IP65 Dimensions 90 x 120 x 25mm Weight 350g Case material ABS Mounting Fix on 4 points Connections Wireless USB Cable external diameter 4 7mm maximum Copper wire section 0 05 2 5mm 14 AWG Temperature Transducer type NTC10KΩ Temperature Measure range 10 C 60 C Temperature Measure accuracy 0 2 C in ...

Page 7: ...ONICA s r l Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it 7 8 WSD12T AV User Manual 10 Mechanical dimensions Picture 8 Mechanical dimensions ...

Page 8: ...e 2011 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception poi...

Reviews: