Contact Caple on 0117 938 7420 or for spare parts www.caple.co.uk

Wall chimney hood instruction manual

SP611 / SP911

SP611BK-SP911BK - Instruction Manual.indd   1

22/03/2016   15:02

Summary of Contents for SP611

Page 1: ...Contact Caple on 0117 938 7420 or for spare parts www caple co uk Wall chimney hood instruction manual SP611 SP911 SP611BK SP911BK Instruction Manual indd 1 22 03 2016 15 02 ...

Page 2: ...CONTENTS Introduction 3 Safety precautions 5 Environmental protection 9 Instructions for installation 11 Operating instructions 16 Care and maintenance 18 Troubleshooting 21 Guarantee and servicing 22 Caple Service contact details 24 SP611BK SP911BK Instruction Manual indd 2 22 03 2016 15 02 ...

Page 3: ... co uk and register here This instruction manual is designed to provide you with all the required information related to the installation use and maintenance of the appliance This hood is designed to extract unpleasant odours from the kitchen it is not intended to extract steam In order to operate the unit correctly and safely please read this instruction manual carefully before installation and u...

Page 4: ...y To protect against fire electrical shock and injury to persons do not immerse cords or plugs in water or any other liquid Never touch the appliance with wet or damp hands Never pull the power cable as you could damage it If the appliance is faulty do not attempt to repair it Isolate it from the mains electric supply and contact Caple Service either by phone 0117 938 7420 or email service caple c...

Page 5: ...enance except by suitably qualified personnel SAFETY PRECAUTIONS Never let children operate the machine The cooker hood is for home use only not suitable for barbecuing restaurants or other commercial purposes The cooker hood and its filter should be cleaned regularly in order to keep in good working condition Clean the cooker hood according to the instruction manual to reduce the risk of fire Whe...

Page 6: ...r hood Never leave frying pans unattended during use as over heated fats and oils may catch fire To ensure the best performance we recommend switching on the extractor 15 minutes before cooking and leave it running 15 minutes after This will ensure that the air in the kitchen is being circulated before cooking commences and the air is being cleaned after cooking has finished The performance of you...

Page 7: ...ppliance in water This product is not designed for commercial use it is a household appliance only It is not intended to be used in Staff kitchen areas in shops offices and other working environments Bed and breakfast type environments By clients in hotels motels and other residential type environments To avoid all risk if the power cable is damaged it must only be replaced by a Caple appointed en...

Page 8: ...this unit into a properly earthed outlet If in doubt seek advice from a suitably qualified engineer Failure to follow these instructions can result in death fire or electrical shock This appliance must be connected to the mains by a competent person We recommend that the appliance is connected by a qualified electrician who is a member of the N I C E I C who will comply with the I E E and local re...

Page 9: ...onsequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The symbol on the product indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment Disposal must be carried out in accordance with local e...

Page 10: ...e reference 10 CE DECLARATIONS OF CONFORMITY This appliance has been manufactured to the strictest standards and complies with all applicable legislation Low Voltage Directive LVD and Electromagnetic Compatibility EMC SP611BK SP911BK Instruction Manual indd 10 22 03 2016 15 02 ...

Page 11: ...ation Measure the floor to ceiling height This hood can be installed on walls between 8ft and 9ft tall Find the centre point of your opening Mark a plumb line through this point from ceiling to your range hob Check your range hob user manual for the minimum distance above your cooking surface The minimum distance between any element or flame height and the nearest combustible surface is 61cm Decid...

Page 12: ...A short straight duct run will produce the most air flow Length and elbows will reduce the efficiency of the blower Install a roof or wall cap Connect a 150mm round duct to the cap and work backwards toward the hood Ensure joints are completely sealed with duct tape Fixing to a wall Before mounting the hood plug in and test all functions for correct operation Remove the filters from the bottom of ...

Page 13: ...o the exhaust piece using duct tape on all seals B A Fixing the chimney flu Carefully loosen but do not separate the telescopic chimney duct pieces Arrange the electrical power supply within the dimensions of the chimney duct Adjust the width of the support bracket to match the upper duct Fix it to the ceiling using the screws so that it is centred in line with your hood and at a distance from the...

Page 14: ...your local dealer for a installation service Note The cooker hood should be placed at a minimum distance of 40 51cm above the hob It is the manufacturer of the hob who determines the clearance required The clearance quoted by the hob manufacturer must be followed In the absence of any instructions supplied with a gas hob the minimum distance between the hob and the bottom of the hood must be at le...

Page 15: ...ion alternatives The cooker hood can be installed in the following ways Circulating indoor air A or outdoor venting B Important If a two part connection tube is used the lower section must sit outside the upper section Do not connect the cooker hood exhaust to a duct used to circulate hot air or vent steam from another appliance Always use protective gloves when installing the appliance SP611BK SP...

Page 16: ...s suspended in the air They will accumulate grease and dirt depending on the frequency of the use of your range hob In order to prevent a fire hazard it is recommended that you clean the aluminium filter at least every 2 months Warning Do not attempt to remove the filters while the cooker hood is operating Disconnect the electrical plug prior to any maintenance This appliance is not intended for u...

Page 17: ...tton it will illuminate you can adjust the timer by using the slider touch control 5 10 and 15 minute delays are available Using the remote control Use the remote to control all hood functions To turn the hood on press any of the fan speeds 1 2 or 3 To change fan speed once the hood is on press any of the fan speeds 1 2 or 3 To activate the timer turn the hood on and press the timer button The blu...

Page 18: ...cooker hood If not cleaned the grease residue which is potentially flammable will saturate the filter Clean with warm water and washing up liquid or clean it in the dishwasher Please ensure no other items are washed with the filters to prevent food becoming trapped in the gauze Cleaning the grease filters in the dishwasher may lead to discolouration this is normal and is a not a fault with the pro...

Page 19: ... prolonged periods of time to light the kitchen Prolonged use of the lights may reduce the lifetime of the bulbs Warning Do not touch or change the bulbs when the hood is operating Wait until the bulb is cool before removing Use the same bulbs as the originals 3W LED Replacement bulbs are available from www caple co uk Removing the LED lights 1 Open the centre panel and remove the grease filter 2 ...

Page 20: ...Instruction manual SP611 SP911 Please keep this instruction manual for future reference 20 300mm 305mm 600 900mm 459mm 800 1170mm 400mm SP611BK SP911BK Instruction Manual indd 20 22 03 2016 15 02 ...

Page 21: ...unning but there is no airflow Butterfly valve jammed Contact Caple Service Motor stops after a few minutes High temperature safety device activated The hood is installed too close to the cooking surface The kitchen is not sufficiently ventilated The hood must be at least 61cm from the stove Strong cooking smell Fan speed is too low Charcoal filters not installed Use a higher setting In recirculat...

Page 22: ...nce has not been serviced maintained repaired taken apart or tampered with by any person not authorised by us All service work under this guarantee must be undertaken by Caple Service Any appliance or defective part replaced shall become the property of this company If a service call is made and it is found that the installation has not been carried out correctly or customer misuse abuse is involv...